DOWNLOAD LG WT-80PV Service Manual ↓ Size: 4.42 MB | Pages: 39 in PDF or view online for FREE

Model
WT-80PV
Pages
39
Size
4.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wt-80pv.pdf
Date

LG WT-80PV Service Manual ▷ View online

 
 
12-2. How to diagnose and maintain according to symptoms 
1)  Power Failure 
Where, what and how 
Check results 
Possible 
reasons 
Solution measures 
Power   
 
Yes 
 
Electric 
problems 
 
1. Check if the socket is in poor 
contact.  
Replace plugs 
Normal  
None 
 
2. measure voltage 
0V Power 
supply 
Contact Power Supply Bureau
 
<1Ω 
 
None  
 
 
Washer harness 
1. Measure power cord resistance with 
plug short-circuit   
Infinite  
Power  cord 
cracks 
Replace power cord 
2. Check if all the connectors are 
connected properly. 
Separation of M and 
F connectors 
Poor contact
Connect again 
3. Check all wire resistance Infinite 
Harness 
cracks 
Replace harness 
<0.5Ω None 
 
>1Ω 
Poor contact
Replace power cord 
10-14V None 
 
Replace 
transformer 
Electrical appliance
0V 
Coil cracks 
Replace filter 
1.check if the fuse is damaged Yes 
Bad 
fuse 
Replace 
filter 
PC board 
 
 
 
Replace PC board if all 
appliances are not damaged. 
 
It must be that PC board damage if 
problems are not mentioned above. 
15% higher than 
standard voltage. 
 
 29
 
 
2)  Display problem 
Where, what and how 
Check results 
Possible reasons 
Solution measures 
Main voltage 
1. measure main voltage 
 
 
Less than 85% of normal 
voltage 
 
Low voltage 
Because of low voltage 
supply. Please use 
transformer if voltage is 
keeping low.   
2. measure external insert 
row voltage if main 
voltage is normal. 
Less than 85% of normal 
voltage 
Wire is too small or there 
are too many 
connections on insert 
row. 
Use transformer 
PC board 
1.  LED damage 
 
2.  LED drive circuit 
damage 
3.  Chips damage 
 
PC board damage 
Replace PC board 
 
 
3)  Restart during working 
Where, what and how 
Check results 
Possible reasons 
Solution measures 
Main voltage 
1.  measure plug voltage 
during working 
 
Less than 80% of normal 
voltage 
 
Main voltage is too low or 
wire size is too small. 
Because of low voltage 
supply and please use 
suitable wire. 
2. restart fault repeats 
during special periods 
 
Temporary voltage surge 
Because of environmental 
condition(high-frequenc
y voltage around) 
3. check if there is voltage 
change.(such as flashing 
lights) 
 
 
Because of power supply 
environment 
PC board 
 
 
Replace PC board 
1. It must be PC board 
fault if there is no 
main voltage fault. 
 
 30
 
 
4)  No water supply 
Check  
Check results 
Possible reasons 
Solution measures 
Inlet valve 
1.  Water is not flowing 
into inner tub and 
there is current flow 
though inlet valve is 
working. 
1)  Check if water tap is 
close. 
 
Close  
Close  
Explanation  
2)  check if the tap is 
open 
No   
Use error 
Open water tab 
3)remove inlet valve and check 
filter if problems are not 
mentioned above. 
Filter is clogged 
No cleaning 
Use a brush to clean the 
filter and filter should be 
cleaned regularly. 
3)  check whether 
membrane hole is 
clogged with foreign 
objects or piston 
inside valve is locked 
if problems are not 
mentioned above.   
 
Inlet valve fault 
Replace inlet valve   
2.  If inlet valve is not 
working and there is 
no current sound 
during water supply. 
1)  Check if connectors 
are not connected or 
connected unproperly. 
Poor connection 
Connection fault 
Connect 
again 
or 
implement 
troubleshooting caused by 
poor connection. 
2)  Check inlet valve 
resistance 
Not between 0 。
8—1。2KΩ 
Coil is cut off 
Replace inlet valve 
Pressure sensor 
1 . If error message “PE” is 
displayed: sensor fault. 
“PE”error display 
Connectors 
do 
not 
connect or harness, coil is 
cut off. 
Connect connectors or 
replace harness. If coil is 
cut off, replace the sensor.
2.Check BP sensor (pressure 
sensor) frequency with no 
load and no water supply.   
Less than 20KHz 
B、P sensor fault 
Replace B、P sensor fault
Yes   
 
Replace PC board 
PC board 
1.If inlet valve and sensor have 
no fault, check the PC 
board. 
 
 31
 
 
5)
 
Continuous or intermittent water supply 
Check  
Check results 
Possible reasons 
Solution measures 
Incorrect installation/water 
leakage 
1 . Check if drain hose is 
placed on the floor.(Pump 
model) 
Yes  
Incorrect 
installation 
Drain hose should be 
hang over standpipe or 
wash tub. Replace parts. 
2.Check leakage place 
Water leakage from 
some parts 
Parts fault 
Repair the parts 
Pressure sensor 
1 . Check if wave wheel 
rotates with no water supply. 
No   
No water pressure sensor
Check  if  pressure  sensor 
pipe is broken and repair 
it. 
2 . Check if air hole is 
clogged there is no sensor 
fault. 
Yes   
Air hole is clogged 
Repair air hole 
Inlet valve 
1.  Is there water supply 
under no power(power 
is off)? 
Yes   
Inlet valve fault 
Replace inlet valve 
PC board 
1.Press “POWER” and there 
is water supply 
immediately before 
“START/PAUSE” 
pressed. 
 Short-circuit 
of 
controlled 
silicon  
Replace PC board 
 
 32
Page of 39
Display

Click on the first or last page to see other WT-80PV service manuals if exist.