LG WM2487HWM Service Manual ▷ View online
56
PUMP
HEATER
THERMISTOR
①
①
Disassemble the cabinet cover.
②
②
Separate the pump hose, the bellows
and the circulation hose assembly from the
pump assembly.
pump assembly.
③
③
Disassemble the pump assembly in arrow
direction.
①
①
Disassemble the cabinet cover.
②
②
Separate 2 connectors from the heater.
③
③
Loosen the nut and pull out the heater.
①
①
Disassemble the cabinet cover.
②
②
Unplug the white connector from the thermistor.
③
③
Pull it out by holding the bracket of the
thermistor.
※
※ CAUTION
• When assembling the heater, insert the
heater into the heater clip on the bottom of
the tub.
the tub.
• Tighten the fastening nut so the heater is
secure.
57
WHEN FOREIGN OBJECT IS STUCK BETWEEN DRUM AND TUB
①
①
Disassemble the cabinet cover.
②
②
Separate the heater from the tub.
③
③
Remove any foreign objects (wire, coin, etc.) by
inserting a long bar in the opening.
LAMP ASSEMBLY
TOP PLATE ASSEMBLY
①
① Unscrew 2 screws on the back of the top plate.
②
② Pull the top plate backward and upward as shown.
③
③ Disconnect the connector.
Disassemble the lamp assembly.
58
MOTOR/DAMPER
1
Disassemble the back cover.
2
Remove the bolt.
3
Pull out the Rotor.
1
Unscrew the 2 screws from the tub bracket.
2
Remove the 6 bolts on the stator.
3
Unplug the 2 connectors from the stator.
1
Disassemble the damper hinges from the tub and
base.
NOTE
If you pull the dampers apart, the must be
replaced. If you do not separate them, they
can be re-used.
59
Checking the TSG (TURBO STEAM GENERATOR)
TSG (TURBO STEAM GENERATOR)
1
To check out the fault diagnosis of TSG, you can
pull out the plug and let the water drain away.
2
Be cautious in case of the TSG is hot.
1
Remove the housing attached to the TSG
(Heater, Water level frequency-sensor,
Thermistor)
2
Remove the screw of the TSG and Body
Frame.