LG WFS2018EKD Service Manual ▷ View online

Problems
49
Stop/Reset the sensor:Stop or reset the sensor by entering Test mode.
12) Power is automatically turned off during operation or immediately turning on
the power button.
Where, what & how to check?
Result of Check
Possible Cause
How to repair & settle
Auto Power Relay or Controller
1. Check whether power is automatically
turned off when turning on the power
switch after unplugging the power cord
from the outlet.
2. It would be defect of the controller if
power is automatically tumed off
immediately when turning on the power
switch even though there is no defects
in the power switch.
Automatically tumed
off
Mechanical defect of the
power switch
Change the switch.
Change the controller.
13)    Sensor
(1) Malfunction
Result of Check
How to repair & settle
Assembling the not- calibrated
controller.
Short 
The sensor is automatically stopped by
the accumulated foreign materials.
Sensor is out of order 
• If the value is not within 1~26 by
checking the controller group.
• When checking the value of the
electrode sensor by Test mode
during the operation
(washing,rinsing, spinning etc.) of the
washing machine, the sensed value
has no change.
• The difference between the sensing
value measured from the supplied
water by a jig and the sensor value of
the product is 5 or more.. 
• Temperature sensor fault : “        ”
displayed Check the operation of
temperature sensor by the QC test
mode.
Recalibrate or replace the controller.
Check the harness, clean the electrode of
sensor
Stop the sensor working*
Change the sensor, clean the electrode of
sensor
Stop the sensor working*
Change the sensor or controller
Check the Harness
50
(2) Inaccurate detecting
(3) How to change Controller Group
Problems
Result of Check
How to repair & settle
the accumulated foreign materials on
the sensor
Inaccurate detecting
• The difference between the sensing
value measured from the supplied
water by a jig and the sensor value of
the product is 5 or more..
• If the value measured from the jig is
normal but the consumer is not
satisfied with
Change the sensor, clean the electrode of
sensor Stop the sensor working*
Change the group of the controller by
entering Test mode.**
**
- If a user wants to detect a Detergent more than the current one
:Increase the group value (by 1~2 step)
- If a user wants to detect a Detergent less than the current one
:Decrease the group value (by 1~2 step)
Turn the power switch on by pressing WASH +PROGRAM and Reservation button together.
Initial Test mode display : All LEDs are off, except I-SENSOR LED
Display the number of TR calibration times : Display “ 
0
” means not calibrated, “ 
1
” for the first time and so on.
The buzzer sounds if there is no controller group.
1. Press Program button once:Display the current Controller Group (1~26)
Program button again :Decrease the controller group by one (display the changed group)
Program button to decrease by one
2. Press START/PAUSE button once :Display the current Controller Group (1~26)(1~26)
Press START/PAUSE button again :increase the controller group by one 
(display the changed group)
START/PAUSE button to increase by one
51
(5) How to use Jig
(6) How to check sensing results
Initial operation: Press "RESERVATION" + "START/PAUSE" botton together after power on, and  press
"RESERVATION" button only again
(displaying the number of pressing button and each data every 0.5 second)
< Fig1 >
Sensor
Terminal
of Controller
How to Connect
• Loosening the front panel of the washing machine
and connect the sensor connecting terminal with
the terminal of the jig.
After supplying water to the washing bath, agitate
for one minute before using the jig.
Record the sensed value of the sensor attached
to the current product at Test mode.
Connect the jig, put the jig sensor into the
washing bath, and record the sensed value of the
sensor.
Determine the sensor performance by comparing
the value measured by the jig and the value
measured by the sensor attached to the product.
1 times : TR Controller Group ( 1 ~ 26 )
2 times : Check the temperature sensor codition
0  : Normal
99 : Temperature senosr’s error, 
(Stop sensing for Temperature and Hardness)
3 times : Temperature of supplied water
4 times : Increment/decrement of washing time according to temperature
5 times : Washing stream at Motor off according to temperature
6 times : The number of comparing the conductivity of washing with rinsing conductvity 
0 ~ 9 : Normal
99 : Abnormal (Stop the sensing of Hardness)
7 times : Sensored result (0 ~ FF:  hexadecimal is displayed)
.
.
.
18 times : Initial stage
52
5. EXPLODED VIEW
TOP COVER
ASSEMBLY
CABINET
ASSEMBLY
TUB ASSEMBLY
Page of 56
Display

Click on the first or last page to see other WFS2018EKD service manuals if exist.