37
4) Water doesn’t come into the wash bowl.
5) Water fills continuously or intermittently.
Where, what & how to check?
Result of Check Possible Cause
How to repair & settle
Wrong Installation/Leakage
1. Check whether the drain hose is 
laying down on the floor. 
(For pump model)
2. Check where water leaks.
Ball Pressure Sensor
1. Check the pulsator is rotating when 
water fills continuously.
2. If there is no defect in the Ball
Pressure Sensor, check whether the
air hole of the outer tub is blocked.
Inlet V alve
1. Does water fills even though it is not
energized (power is off)?
Controller
1. Does water fill immediately after the
power switch turns on before pushing 
the start/pause button.
Drain hose 
laying down.
Water leaks 
from a part.
It doesn ’t 
rotate.
Blocked.
Water fills.
Wrong  installation. 
Defect of the part.
Water  pressure  is
not sensed.
Air hole blocked.
Defect of the inlet
valve.
Short circuit of the 
triac of the 
controller.
The drain hose 
should be hung on the 
stand-pipe or the tub.
Change the part.
Repair it.
Check the tube of the  
Ball Pressure Sensor, it
is bent
or blocked, repair that.
Repair the blocked hole.
Change the inlet valve.
Change the controller.
Where, what & how to check?
Result of Check Possible Cause
How to repair & settle
Ball Pressure Sensor
1. Is there PE error on the display 
which means Ball Pressure Senosr
error
2. Check frequency of the Ball
Pressure Sensor without load if
wash is proceeding without filling.
Controller
1. Defect of controller is highly possible
if inlet valve and Ball Pressure
Sensor have no defects in the
above.
Reconnect the connector
or change leads. Change
the Ball Pressure Sensor
if coil is open. 
Change the pressure
switch.
Change the controller.
PE Error 
displayed. 
Less then 
26.2
Connector is taken
off, or lead or coil is
open.
Defect of the Ball
Pressure Sensor
38
6) Pulsator doesn’t rotate normally.
Where, what & how to check?
Result of Check Possible Cause How to repair & settle
Pulsator rotates at one 
direction .
1. The Pulsator rotates normally at the 
beginning of wash cycle, but is it not
rotate at clockwise direction (locked) 
after some wash cycles though there
is motor-working sound?
2. In the case the pulsator doesn ’t 
rotates either clockwise or 
counterclockwise from the beginning
of wash cycle:
1) Check resistance of the wash 
motor if there is no motor-working
sound.
2) Check belt tension & whether the 
clutch rotates normally if there is 
motor-working sound.
3. The pulsator doesn ’t rotate at both 
directions.
1) Check whether motor rotates at 
both directions if there is motor-
working sound when it ’s 
energized.
2) Check resistance of the motor if 
there is no motor-working sound.
Clockwise
rotation locked.
Resistance 
is normal.
V-belt is loose.
Clutch locked.
Motor rotates 
at both
directions.
Motor doesn ’t 
rotates  at  both
directions.
Normal 
resistance.
Unusual operation.
Defect of 
controller or poor 
contact of 
connectors of 
motor leads.
Loose the belt.
Defect of the
clutch.
Loose the belt.
The plusator 
locked.
Defect of the 
clutch.
Defect of the 
capacitor.(check
the capacitor ’s 
capacitance)
Defect of the
motor. 
Motor coil is open.
Contact defect of
the leads.
Turn the power off 
and on again then that 
symptom disappears.
Explain  “Don’t run wash 
only continuously ”.
Change the controller if 
there are no contact 
defects in the leads of
the motor.
Adjust belt tension by 
changing motor fixing 
location and change the 
belt if it is impossible to 
adjust belt tension. 
Change the clutch if the 
clutch pulley is locked 
when making it rotated 
clockwise and 
counterclockwise by 
hand.
Adjust belt tension or 
change the belt if it is 
impossible to adjust.
Remove cause 
locking the pulsator
Change the clutch.
Change the motor if the 
motor is locked when 
having its shaft rotated 
by hand.
Change the capacitor if 
there is no contact defect 
in capacitor ’s lead
Change the motor.
Remove the causes.
39
7) Water does not drain.
Where, what & how to check?
Result of Check Possible Cause How to repair & settle
4. Check whether the drain hose is 
blocked by foreign objects. It may 
happen in case of the hose is a little 
kinked.
PV Case
(for Non-Pump Model only)
1. Check whether the PV asm is
blocked by foreign objects.
Drain Motor
(For Non-Pump Model only)
1. Check resistance of the drain 
motor if it can not pull the PV link.
Blocked.
Blocked.
Resistance is 
normal.
Blocked hose.
Drain motor coil is
open.
Contact defect in 
connection parts 
or defect of the 
controller.
Remove the objects and
reinstall  so  that  it  can ’t
be kinked.
Separate the drain motor
from the PV link,
disassemble PV cover
and then remove the
foreign objects within 
PV case.
Check the washer works
normally after repair 
and reassembling them.
(PV link & drain motor
lever should be 
assembled accuratel.)
Change the drain motor 
Check the washer 
works normally after 
reassembling.
(PV link & drain motor 
lever should be
assembled accurately.)
Change the controller if 
there is no defects in the
connection parts.
40
8) Water drains though it is not the time of drain.
Where, what & how to check?
Result of Check Possible Cause How to repair & settle
Drain Motor
(for Non-Pump Model only)
1. Check whether the drain motor is 
normally returned after turning 
power off.
(It is considered normal if the lever 
of the drain motor is fully pulled out 
by the PV spring)
PV Case
1. If water drains though the drain 
motor is normally returned, check 
whether PV asm is blocked by 
foreign objects or the bellows in 
the PV asm is deformed.
Controller
1. Check whether the drain motor or 
the drain pump works immediately
after power is turned on.
Blocked.
Blocked.
Bellows
deformed.
Works. 
Defect of the drain
motor.
Defect of PV 
Bellows.
Defect of the 
controller(Triac 
defect)
Change the drain motor.
Remove the objects in 
the PV asm.
Change the PV bellows.
(The bellows may swell 
up if it contact petroleum
or petrochemical 
substance because it is 
made of rubber)
Change the controller.
9) Drain error happens while water drains normally.
Where, what & how to check?
Result of Check Possible Cause How to repair & settle
Ball Pressure Sensor
1. Check generation frequency of the 
Ball Pressure Sensor without water.
Less than
26.3 kHz
26.3~27.1 kHz
Defect of the 
Ball Pressure
Sensor.
Defect of the 
controller.
Change the Ball
Pressure Sensor
Change the controller.
Page of 49
Display