DOWNLOAD LG WD-BABYLUV1 Service Manual ↓ Size: 41.62 MB | Pages: 44 in PDF or view online for FREE

Model
WD-BABYLUV1
Pages
44
Size
41.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-babyluv1.pdf
Date

LG WD-BABYLUV1 Service Manual ▷ View online

36
INLET VALVE
1
Disconnect the wiring receptacle.
2
Unscrew 2 screws from the back.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
When reconnecting the connector
LOWER COVER
Open the lower cover cap by using coin and
pull out the lower cover to the arrow direction
after a screw is unscrewed.
VALVE #1 (MAIN) 
VALVE #2 (PRE) 
White / Black - Black
Gray / White - Black
DOOR
1
Open the door completely.
2
Remove the two screws from the hinge.
When removing the door assembly, it is
necessary to hold the bracket that is inner
of the cabinet cover.
1
2
37
1
Take  apart  the  cabinet  gasket  clamp.
2
Unscrew  2  screws  from  the  cabinet  cover.
4
Take  apart  the  lower  cover.
3
Open  the  lower  cover  cap  and  unscrew  1
screw  inside.
1
Disassemble  the  control  panel.  (page  24)
2
Unscrew  all  the  screws  on  the  upper  and  lower
sides  of  the  cabinet  cover.
1
Take  apart  the  tub  gasket  clamp.
2
Make  sure  that  the  drain  hole  of  the  gasket  is
put  beneath  when  reassembling  the  gasket.
efer  to  the  arrow  mark  on  the  tub  cover.
GASKET  ASSEMBLY
38
1
Remove  the  BACK  COVER.
2
Unscrew  the  bolt  to  pull  out  the  ROTOR
assembly.
1
Disconnect  the  wiring  connector.
2
Unscrew  6  bolts  from  the  STATOR.
3
Remove  the  STATOR.
1
Pull  out  the  hinge,  pressing  its  snap.
2
Do  not  use  the  pulled-­out  hinge  again.  It  may
be  taken  off  during  operation.
ROTOR  ASSEMBLY,  STATOR  ASSEMBLY,  FRICTION  DAMPER  ASSEMBLY
Rotor
Bolt
(1)
Hinge,
Damper
Damper
(ROTOR  ASSEMBLY)
(STATOR  ASSEMBLY)
(DAMPER)
‡9a8aŸ)
‡8a:aŸ)
‡:a9aŸ)
Note  :  Hook  of  connector  (1)  is  on  the  backside
Motor  Stator
89:
‡&RPPRQa+DaNŸ)
‡&RPPRQa+EaNŸ)
Hall  Sensor
Ha
Hb
Common
39
PUMP
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
HEATER
1
Loosen the M6 heater nut to pull out the
heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
Tub Pump 
Bellows
Pump Outlet Hose
• Rating : 220~240V 1600W
• Resistant : 24.7~28.0Ω
• Rating : 220~240V 50HZ 30W
• Resistant : 160~177Ω
M6 heater nut
Page of 44