LG WD-14376FDM Service Manual ▷ View online

13
7. TROUBLE SHOOTING
7-1. BEFORE SVC CHECKING
Be careful of electric shock or disconnecting the parts while trouble shooting.
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
7-2. QC TEST MODE
1 Pressing Rinse and Steam Wash button simultaneously.
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
Press the Rinse and Medic Rinse button simultaneously.
2 Press the Power      button, while the above condition.
3 Press the Start/Pause button as follows.
None 
1 time 
2 times 
3 times 
4 times 
5 times 
6 times 
7 times 
8 times 
9 times 
10 times 
11 times 
12 times 
13 times 
14 times 
15 times
Turns on all lamps and locks the door.
Tumble clockwise. 
Low speed Spin. 
High speed Spin. 
Inlet valve for prewash turns on. 
Inlet valve for main wash turns on. 
Inlet valve for hot water turns on. 
Inlet valve for steam turns on. 
Inlet valve for bleach turns on. 
Tumble counterclockwise. 
Heater turns on for 3 sec. 
Circulation pump turns on. 
Drain pump turns on. 
Water level Sensor for Steam  
Steam Heater turns on for 1.2 sec. 
Off
rpm (42~50)
rpm (55~65)
rpm (125~155)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
rpm (42~50)
Water temperature
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency of TSG (0~255)
TSG temperature
-
The digits indicate the water level frequency.
So, for example a display indicating 058:
a Water level frequency of 20+(58 x 0.1)= 25.8 kHz
Number of times the
Start/Pause button is pressed
Check Point
Display Status
QC TEST MODE
VIEWING DATA
045
000
000
055
000
061
028
028
000
000
029
000
064
048
000
000
222
290
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT OPERATING CONDITION.
Press the Rinse and Medic Rinse button simultaneously.
Thermistor in tub temperature.
VIEWING DATA
045
000
000
055
000
061
028
028
000
000
029
000
064
048
000
000
222
290
14
7-5. ERROR DISPLAY
If you press the Start/Pause button in error condition, any error except ‘        ’ will disappear and the
machine will change into pause status.
In case of ‘        ’, ‘        ’, if the error is not resolved within 20 sec., and in case of other errors, if the
error is not resolved within 4 min., power will be turned off automatically and the error only will be
blinked. But in case of ‘        ’, power will not be turned off.
ERROR
SYMPTOM
CAUSE
WATER INLET
ERROR
• Not reached to the water level(246)within 8 minutes
after water supplied or not reached to the preset
water level within 25 minutes.
1
DRAIN ERROR
• Not fully drained within 10 minutes.
2
OVERFLOW ERROR
• Water is over flowing(over 8 level).
If ‘         ’ is displayed, drain pump operates to 
drain water automatically.
3
SENSOR PRESSURE
S/W ERROR
• The sensor pressure switch is out of order.
4
DOOR OPEN ERROR
• In case of operating the reservation function or the
other function with door opened. Close the door,
then the error display is resolved.
• The door switch is out of order.
5
IMBALANCE ERROR
• The appliance is tilted.
• Laundry is gathered to one side.
6
HEATING ERROR
• The THERMISTOR is out of order.
7
15
ERROR
SYMPTOM
CAUSE
LOCKED MOTOR
ERROR
• The connector in the LEAD WIRE ASSEMBLY is
not connected to the connector of STATOR
ASSEMBLY.
Reconnect or repair the connector.
• The hall sensor is out of order/defective.
Replace the STATOR ASSEMBLY.
8
• Water leaks.
9
POWER FAILURE
• The washer experienced a power failure.
10
7-6. HOW TO KNOW THE TUB AND AG TEMP.
Press the Rinse and Temp. button simultaneously.
The digits indicate the water Temp. in the Tub
The digits indicate the water Temp. in the AG
VIEWING DATA
045
000
000
055
000
061
028
028
000
000
029
000
064
048
000
000
222
290
16
8. ERROR DIAGNOSIS AND CHECK LIST
8-1. DIAGNOSIS AND ANSWER FOR ABNORMAL OPERATION
SYMPTOM
GUIDE FOR SERVICE CALL
• NO POWER
• WATER INLET TROUBLE
Is the power plug connected firmly to
220-240V~ outlet?
Power failure? or Breaker opened?
Is "          " displayed?
Is the tap opened?
Is the tap frozen?
Is the water supply shut-off?
Visit to check
Is filter in the inlet valve clogged with
foreign material?
Clean the filter of
inlet valve.
YES
NO
YES
YES
NO
NO
NO
YES
Visit to check