LG WD-12125RD Service Manual ▷ View online
24
Wash
Rinse
NO
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
PWB ASSY(Main)
AC 220V-240V
(1)
(2)
Replace the
S.PRESSURE SWITCH
ASSEMBLY
Replace the MAIN PWB
ASSEMBLY
ASSEMBLY
Repair the DRAIN HOSE
ASSEMBLY.
Remove foreign material.
Reconnect or repair the
connector
connector
Repair the DRAIN PUMP
ASSEMBLY.
Repair the MAIN PWB
ASSEMBLY.
When pressing Wash and Rinse at the same time
after draining, is the water level frequency 248 ~ 262
or more?
When pressing Rinse, Spin buttons at the same
time while wash, is the water level frequency
between 230 - 243?
after draining, is the water level frequency 248 ~ 262
or more?
When pressing Rinse, Spin buttons at the same
time while wash, is the water level frequency
between 230 - 243?
Checking voltage between two pins as press the
POWER button is the voltage 220-240V~?
POWER button is the voltage 220-240V~?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected, disassembled?
Is the coil of the drain pump cut-off?
(resistance of coil is 80~150 )
When checking voltage between connectors
( , )on spinning, is the voltage 220-240V~
as the figure?
HEATING WITHOUT WATER
D R A I N M A L F U N C T I O N I N G
25
Push the THERMISTOR
tightly to the rubber.
tightly to the rubber.
When checking THERMISTOR on the tub is the
THERMISTOR loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
26
Rinse
Spin
Wash
Rinse
NO
YES
YES
YES
NO
YES
YES
NO
NO
NO
YES
(1)
(1)
(2)
Door Lock
S P I N T R O U B L E
D O O R D O E S N O T O P E N
Check the S.PRESSURE SWITCH
ASSEMBLY or HOSE (Pressure).
If the problem is on the
S.PRESSURE SWITCH
ASSEMBLY or the HOSE,
replace the S.PRESSURE
SWITCH ASSEMBLY or the
HOSE.
ASSEMBLY or HOSE (Pressure).
If the problem is on the
S.PRESSURE SWITCH
ASSEMBLY or the HOSE,
replace the S.PRESSURE
SWITCH ASSEMBLY or the
HOSE.
Normal
Correct the connector.
Replace the STATOR
ASSEMBLY
ASSEMBLY
Check on the spinning, is the frequency of the
water level 248 or more. The frequency can be
checked by pressing the Wash and Rinse buttons at
the same time on the program.
water level 248 or more. The frequency can be
checked by pressing the Wash and Rinse buttons at
the same time on the program.
When pressing Rinse, Spin and POWER buttons at
the same time after power off, press the Start/Pause
button 1 times, is the drum low speed spin?
the same time after power off, press the Start/Pause
button 1 times, is the drum low speed spin?
Is it disconnected, or disassembled?
[Red:3pin(1), NA:4pin(2)]
[Red:3pin(1), NA:4pin(2)]
Check the motor connector, is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal:
About 5
15
Replace the MAIN PWB ASSEMBLY
Is Door lock Display lamp on?
After draining and
Door lock lamp off,
open the door.
Check switch Assembly,
Door lock connector and
Main PWB
ASSEMBLY(Blue, 3pin)
Door lock connector and
Main PWB
ASSEMBLY(Blue, 3pin)
Is
Displayed?
27
Disassemble the cabinet cover and
condensing bellows.
Is there any foreign object in condensing
bellows.
condensing bellows.
Is there any foreign object in condensing
bellows.
Clean the bellows
[dHE] ERROR DISPLAY
CHECK FOR DRY HEATER TROUBLE
CHECK FOR DRY FAN MOTOR TROUBLE
NO
YES
Replace the thermistor.
(6322FR2046B)
(6322FR2046B)
YES
NO
Disassemble the dry fan assy and dry duct
upper, and clean foreign object in duct and
fan.
upper, and clean foreign object in duct and
fan.
Dry duct
Condensing
duct
duct
Condensing bellows
Thermistor
~