LG SP105 Service Manual ▷ View online
28
YES
YES
YES
NO
NO
NO
YES
DRAWER
DRAWER
CAP
Is water supplied?
Are the plugs correctly connected to the terminals
of the INLET VALVE ASSEMBLY?
of the INLET VALVE ASSEMBLY?
Is detergent/softener/bleach put in the correct
compartment of the DRAWER?
compartment of the DRAWER?
Is the detergent/softener/bleach CAP clogged?
Refer to page 22
IE ERROR
Check the wiring.
Put it in the correct
compartment
compartment
Clean the CAP and
DRAWER
DRAWER
DETERGENT/SOFTENER/BLEACH DOES NOT FLOW IN
ABNORMAL SOUND
Secure the bolt.
Replace the STATOR
ASSEMBLY or ROTOR
ASSEMBLY.
ASSEMBLY or ROTOR
ASSEMBLY.
Is the motor bolt loose?
Is there friction noise coming from the motor?
29
(1)
AC 220-240V
220~240 V
4
8
8
7
Push the THERMISTOR
tightly to the rubber.
tightly to the rubber.
When checking the THERMISTOR on the tub,
is the THERMISTOR loose?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
WASH HEATER TROUBLE
30
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
WILL NOT CIRCULATE WATER
Is the impeller of the drain pump clogged?
Are the Hose Connector and/or Hose clogged?
Is the connector disconnected, disassembled?
Is the coil of the right side of drain pump open
or short circuited? (Coil R is 18-30 Ω)
or short circuited? (Coil R is 18-30 Ω)
When checking voltage between the
connectors during spin, is the voltage
220~240 V AC, as the figure?
connectors during spin, is the voltage
220~240 V AC, as the figure?
Remove foreign material.
Remove foreign material.
Reconnect or repair
the connector.
the connector.
Replace PUMP MOTOR
ASSEMBLY.
ASSEMBLY.
Replace the MAIN PWB
ASSEMBLY.
ASSEMBLY.
31
YES
YES
SUDS OVERFLOW FROM THE APPLIANCE
Is HE(High Efficiency) detergent used?
Is the proper amount of detergent used
as recommended?
as recommended?
Recommend to reduce the amount
of detergent.
of detergent.
This appliance has an automatic suds sensing function which
prevents overflow.
prevents overflow.
When excessive suds are sensed, the suds removing
implementations such as drain, water input, and pause will
operate, without rotating the drum
implementations such as drain, water input, and pause will
operate, without rotating the drum