DOWNLOAD LG F1443KDS / F1443KDS7 / F1443KDS9 Service Manual ↓ Size: 14.07 MB | Pages: 64 in PDF or view online for FREE

Model
F1443KDS F1443KDS7 F1443KDS9
Pages
64
Size
14.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f1443kds-f1443kds7-f1443kds9.pdf
Date

LG F1443KDS / F1443KDS7 / F1443KDS9 Service Manual ▷ View online

17
Wiring Diagram 3/3
18
PCB Layout (Main)
  
Earth Wire Connector
 
19
Before servicing ask the customer what the trouble is.
Check the adjustments. (Power supply :220-240V~, Removal of transit bolts etc..)
Check the troubles referring to the troubleshooting.
Decide service steps referring to disassembly instructions.
Then, service and repair.
After servicing, operate the appliance to see whether it works OK or NOT.
7. TROUBLESHOOTING
7-1. BEFORE SVC CHECKING
7-2. LOAD TEST MODE
1 Press and Hold ‘
Option (Right)
’ & ‘
Rinse
’ buttons
and then press ‘
Power
’ button.
2 The washer must be empty and the controls must be in the off state.
3 Press Power with above two buttons pressed and then buzzer will sound.
4 Press the Start/Pause button repeatedly to cycle through the test modes
1
2
3
4
5
6
None 
1 time 
2 times 
3 times 
4 times 
5 times 
6 times 
7 times 
8 times 
9 times 
10 times 
11 times 
12 times 
13 times
14 times  
Turns on all lamps and locks the door.
Tumble clockwise.
Low speed Spin.
High speed Spin.
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for steam turns on.
Turmble counter clockwise
Heater turns on for 3 sec.
Circulation pump turns on.
Drain pump turns on.
Water level 
Sensor for Steam
Steam Heater turns on for 1.2 sec.
Off
rpm (42~50)
rpm (60)
rpm (130~140)
Water level frequency
Water level frequency
Water level frequency
Water level frequency
rpm
Water temperature
Water level frequency 
Water level frequency 
AG Temperature
-
Number of times the
Start/Pause button is pressed
Check Point
Sw 2,3 open
Sw 2,3 op
Display Status
20
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY 
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
040
045
000
100
021
041
045
097
000
045
112
000
248
084
000
026
145
000
The digits indicate the water level frequency.
So, for example a display indicating 255 :
a water level frequency of (255 X 0.1) = 25.5KHz
Data View Type : In case of ‘040’
Press the 
Temp.
and 
Pre wash
button simultaneously.
If the knob turn around, The data view type is changed from 40 to 49
Press the 
Temp.
and 
Pre wash
button simultaneously.
If the knob turn around, The data view type is changed from 40 to 49
040
045
000
100
021
041
045
097
000
045
112
000
248
036
000
026
145
000
Thermistor in tub temperature
Data View Type : In case of ‘040’
Page of 64
Display

Click on the first or last page to see other F1443KDS / F1443KDS7 / F1443KDS9 service manuals if exist.