LG F1092QDT2 / F1092QDT25 / F1092QDTA5 Service Manual ▷ View online
40
PUMP
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
HEATER
1
Loosen the M6 heater nut to pull out the
heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
the heater into the heater clip on the bottom
of the tub.
Tub Pump
Bellows
Pump Outlet Hose
• Rating : 220~240V 2000W
• Resistant : 24.7~28.0Ω
• Rating : 220~240V 50HZ 30W
• Resistant : 160~177Ω
M6 heater nut
4
1
SWITCH ASSEMBLY, DOOR LOCK
1
Take apart the cabinet cover clamp and
release the gasket.
2
Unscrew 2 screws holding the door lock.
3
Disconnect the door lock from the wiring
connector.
WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB
1
Remove the heater.
2
Remove the foreign material (wire, coin and
others) by inserting a long bar through the
hole.
• Just check cut-off.
• Check the operating time.
* Door Locking time :
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
input the power to parts
move up, then Door locked.
* Door Releasing time :
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
the power to parts
move down, then Door released.
1
1
1
A150
A153
A141
A131
A130
A151
A133
A310
A300
A221
A220
A200
A440
A430
A485
A101
A110
A410
A270
F160
F430
A450
F110
F210
F310
F301
F302
F225
F462
F321
F220
F215
Click on the first or last page to see other F1092QDT2 / F1092QDT25 / F1092QDTA5 service manuals if exist.