36
9. COMPONENT TESTING INFORMATION
9-1. FILTER ASSEMBLY (LINE FILTER)
When Resistance (Ohm) checking the Component, be sure to turn the power off,
and do voltage discharge sufficiently.
WARNING
Circuit
diagram
Circuit in the MAIN PWB/Circuit diagram
Vac
MAIN PWB
ASSEMBLY
FUSE
RD1
WH1
LI
L2
RI
CI
C2
C3
3
2
1
3
2
1
Test
points 
and 
Result
Test Points
Result
WH (1) to RD (3)
WH (3) to RD (1)
1
1
(3)
(1)
WH1
(3)
(1)
RD1
37
9-2. DOOR LOCK SWITCH ASSEMBLY
Circuit
diagram
Circuit in the MAIN PWB
MAIN PWB
Vdc
Vac
MICOM
12V
12V
4
1
3
2
4
1
3
2
Relay
Relay
NA4
1
2
3
4
1
2
3
4
2
3
4
PTC
PTC
Door switch
SOLENOID
5
YL
BL
RD
BK
AC
Common
terminal
of Valve
Function
The Door Lock Switch Assembly consists of a Heating PTC, a Bimetal, a
Protection PTC, and a Solenoid. It locks the door during a wash cycle.
1. Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2~4’s
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven,
force the system to the off position through CAM.
Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will
make the door locked.
- Door lock is detected when switches in terminal 4~5 are set closed.
CAM rotation will forcibly clear off the connection. 
The maximum, allowable number of impulse authorizations is 2
Upon the third authorization of the impulse, 
the position of CAM goes back to the door-open position.
- Authorizing the impulse occurs in 4.5 seconds upon input for max
performance and two authorization processes are allowed at most.
Normal operation period of PTC heating: 1.5 - 5 seconds 
(Defects from the development process)
2. Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations after
authorizing the impulse from the terminal 3 ~ 4 and the power turns off -
maximum of 3 times of the authorizing period 
- Upon the fourth authorization of the impulse, the position of CAM goes
back to the door-close position.
38
Test
points
Result
Test Points
(2) to (4)
(3) to (4)
(4) to (5)
(2) to (4)
Result
700-1500 
1
60-90 
1
Infinity
120 Vac
Remarks
At 77
°F 
(25
°C
)
At 77
°F 
(25
°C
)
Voltage Input
(2)
(3)
(4)
(5)
39
9-3. STATOR ASSEMBLY
Circuit
diagram
Circuit in the MAIN PWB 
MAIN PWB
MICOM
Ha
12V
NA1NA
WH
WH
GND
MOT
OR
Hb
Ha
RD
RD
BL
BL
GY
YL
w
w
v
u
v
u
BL
RD
RD
RD4
IPM
GY
YL
w
u
v
BL
RD
1
1 1
2
3
4
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
3
2
2
1
3
4
1
2
3
4
5
1
2
3
4
5
2
3
4
1
2
3
4
Hb
Function
Test points
(Windings)
Result
(Windings)
The DD motor can be driven from stopped to maximum speed in infinite steps in
either direction. There are 36 poles on the stator; 12 permanent magnets spaced
around the rotor. There are no brushes to wear out. Unlike a more traditional
brushless motor, the rotor surrounds the stator rather than being attached to it. 
Test Points
Result
(1) to (2)
(2) to (3)
(3) to (1)
5-15 
1
5-15 
1
5-15 
1
WINDINGS
HALL SENSOR
(1)
(2)
(3)
Page of 59