DOWNLOAD LG 50PJ350R-TA (CHASSIS:PP01A) Service Manual ↓ Size: 15.39 MB | Pages: 34 in PDF or view online for FREE

Model
50PJ350R-TA (CHASSIS:PP01A)
Pages
34
Size
15.39 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
50pj350r-ta-chassis-pp01a.pdf
Date

LG 50PJ350R-TA (CHASSIS:PP01A) Service Manual ▷ View online

ⓒ LG Electronics. Inc.2009
Check IR operation
Power 
LED ON?
Latest S/W update
from GCSC 
(Firmware Management)
N
Y
OSD
appear?
Y
N
Y
N
Close
Making 
Revision 
PDP TV
Symptom
A. Picture Problem
No Picture/No Sound
Repair Process
Check Module pattern 
by using “TILT” key
on SVC R/C
Normal
N
Check
Sound
Sound
OK
Y
N
Move 
No Picture/ Sound Ok
Section
Close
Y
Check 
LVDS Cable 
Replace
Main B/D
Normal
Y
N
Replace
Main B/D
Normal
Check Input signal
. RF Cable connection
. SCART Cable connection
. HDMI Cable connection
. Component Cable …
2
Normal
Y
N
Repair/Replace
IR B/D
ⓒ LG Electronics. Inc.2009
Making 
Revision 
PDP TV
Symptom
A. Picture Problem
Mal-discharge/Noise/dark picture
Repair Process
Y
N
N
Mal-discharge
Dot 
type
Check CTRL ROM Ver.
and
Rom Upgrade
Normal 
Picture?
Y
Close
Replace
Control board 
Normal 
Picture?
Y
Close
Replace
Module 
N
Scan
Type
Check
Picture problem
Type
Check voltage
. –V
/  V
SC
(Y-Sus B/D)
Normal 
Picture?
Replace
Y-Sus B/D 
Normal 
Picture?
Y
N
1.Check Control B/D
2.Replace Board
Normal 
Picture?
Check 
Y Drive B/D 
Replace B/D
Y
Close
N
Dark Picture
Normal 
Picture?
Y
Replace
Module 
N
Close
1. Check Z-Sus Board
2. Replace Board
Check 
Picture mode
setting 
Picture Noise
Normal 
Picture?
Y
N
Close
Y
N
Check RF Cable
Connection
Check Tuner 
& Replace
Normal 
Picture?
Check Discharge resistance (10Ω 2~3ea)  
on Power B/D before replace Y Drive B/D
Close
Close
3
ⓒ LG Electronics. Inc.2009
Making 
Revision 
PDP TV
Symptom
A. Picture Problem
Picture broken/Freezing
Repair Process
Y
4
N
Check RF Signal level
Normal 
Signal?
Check RF Cable 
Connection
1. Reconnection
Check
S/W Version
S/W Upgrade
Check whether other equipments have problem or not.
(By connecting RF Cable at other equipment)
→ DVD Player ,Set-Top-Box, Different maker TV etc
SVC 
Bulletin?
Replace
Main B/D
Check
Tuner soldering
Normal 
Picture?
Y
N
Y
Close
Normal 
Picture?
Y
Close
. By using signal level meter
- Signal strength (Normal : over 50%)
- Signal Quality    (Normal: over 50%)
Normal 
Picture?
Y
Contact with signal distributor
or broadcaster (Cable or Air) 
N
N
Normal 
Picture?
Y
Close
N
ⓒ LG Electronics. Inc.2009
Making 
Revision 
PDP TV
Symptom
A. Picture Problem
Vertical bar/ Horizontal Bar
Repair Process
Check
defect type
Y
N
Y
5
Vertical
Line/Bar
Regular 
Vertical
Line / Bar
Check Module pattern 
by using “TILT” key
on SVC R/C
Normal 
Pattern?
1.Check CTRL B/D
2.Replace Board
Replace
Module 
Irregular 
Vertical
Line / Bar
1.Check CTRL B/D
2.Replace Board
Normal 
Picture?
Check Main B/D
Replace  Module
(If Main B/D doesn’t cause)
N
Y
Close
1.Connector re-connection
2.Eliminate foreign material on Connector
N
※CTRL B/D: Control board
Check connection
of Connector
(COF,TCP)
on CTRL B/D , X B/D
Check connection
of Connector (FPC)
on Y Drive B/D 
1.Connector re-connection
2.Eliminate foreign material  on FFC
1. Check Y Drive B/D
2. Replace Board     
Normal 
Picture?
N
Y
Close
Replace
Module 
1.Check CTRL B/D
2.Replace Board
Normal 
Picture?
N
Y
Close
N
Y
Normal
Horizontal
Line/Bar
Normal
Half
No picture
1.Check X B/D
2.Replace Board
Normal 
Picture?
Y
Close
Replace
Module 
N
※ H-Line’s Cause is rare CTRL B/D
Page of 34
Display

Click on the first or last page to see other 50PJ350R-TA (CHASSIS:PP01A) service manuals if exist.