- 13 -
2. No Power
(1) Symptom
1) Doesn’t minute discharge at module. 
2) Non does not come in into the front LED. 
(2) Check following
A Power cord is plugged with TV set?
Plug in power cord.
Yes
No
Is the AC-INLET connected with 
the power board?
Connect the AC-INLET
Yes
No
Is the Fuse(F101,F801) on
Power Board normal?
Replace the Fuses.
Yes
No
Is the Power Board with
VSC Board though Cable connected?
Connect the Cable.
Yes
No
Measure output voltages(16V,12V,5V) on the power board.
If the measured values is not normal, replace power board.
- 14 -
3. Protect Mode
(1) Symptom
1) After once shining, it does not discharge minutely
from module.
2) The Rely falls.(The sound is audible “click”) 
3) It is converted with the color where the front LED 
is red from green.
(2) Check following
Is the Power Board
normal ?
Replace Power
Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is the each connector
normal?
Replace the
connector.
Replace
Y-Board.
After connecting well each connector,
the normality it operates? 
Yes
No
Yes
Is the Ctrl Board
normal?
Replace
X-Board.
Is the output voltage normal after
remove P163 connector of Ctrl-B/D?
Yes
No
Yes
Is the Y-Board
normal?
Is the output voltage
normal after remove
P209 connector of
Y-B/D?
Is the Fuse(FS201) on Y-B/D
normal?(In case of open is replace)
Yes
No
Yes
Yes
Replace
Z-Board.
Is the Z-Board
normal?
Is the output voltage
normal after remove
P3 connector of Z-
B/D?
Is the Fuse (FS1) on Z-B/D normal?
(In case of open is replace)
Yes
No
Yes
Is the X- Board
normal?
Is the output voltage normal after
remove P242 connector of
X-B/D?
After remove P211 output voltage normality:
Replace Right X-B/D
After remove P23 output voltage normality:
Replace Left X-B/D
Yes
No
Yes
Is the 
VSC Board normal?
Is the output voltage normal after
remove P1001 of VSC Board?
After crisis COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is replace the module.
After remove P1001 normal operation:
Replace VSC Board
Yes
No
Is the COF of X, Y, Z
normal ?
No
Yes
Yes
- 15 -
Does minute discharge
At Module?
Is the LVDC cable
normal?
Is the VAVS on?
Check the PDP Module
Yes
No
YES
Yes
Reconnect the LVDS
cable in P501
No
Is the IC700(FLI106X0H)
Output normal?
Replace the VSC.
No
NO
Replace the Power
board
Is output the normality
Low/High voltage except
stand-by 5V?
NO
4. No Raster
(1) Symptom
1) No OSD and image occur at screen. 
2) It maintains the condition where the front LED is green.
(2) Check following
- 16 -
5. In case of occurring strange screen into specific mode
5-1. In case the OSD does not displayed
(1) Symptom
1) LED is green.
2) The minute discharged continuously becomes Accomplished from module.
(2) Check following
Is the LVDS cable
normal ?
Is the VSC Board
normal?
Is the LVDS cable
connected?
Re-insert the Cable inserts.
Yes
No
No
Yes
Is the IC100(FLI106X0H)
normal?
Replace
IC100(FLI106X0H)
No
Is the Ctrl Board of
Module normal?
Replace Ctrl B/D.
No
No
Yes
Replace the VSC B/D
Replace the cable.
Yes
Page of 34