DOWNLOAD LG 50PB2RR-TL (CHASSIS:MF-056L) Service Manual ↓ Size: 20.89 MB | Pages: 59 in PDF or view online for FREE

Model
50PB2RR-TL (CHASSIS:MF-056L)
Pages
59
Size
20.89 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
50pb2rr-tl-chassis-mf-056l.pdf
Date

LG 50PB2RR-TL (CHASSIS:MF-056L) Service Manual ▷ View online

- 21 -
2. No Power
(1) Symptom
1) Doesn’t minute discharge at module. 
2) Non does not come in into the front LED. 
(2) Check following
Is plug in power cord?
Plug in power cord.
Yes
No
Is the Line Filter and Power
Board Cable connected?
Connect the Cable.
Yes
No
Is the Fuse(F101) on
Power Board normal?
Replace the Fuse.
Yes
No
Is the Power Board and 7P of
VSC Board Cable connected?
Connect the Cable.
Yes
No
After the cable connect is removed
to Power Board(except the CN101
connection cable), the AC voltage
marking is authorized on manual.
When ST-BY 5V is not operated,
replace Power Board.
- 22 -
3. Protect Mode
(1) Symptom
1) After once shining, it does not discharge minutely
from module.
2) The Rely falls.(The sound is audible “click”) 
3) It is converted with the color where the front LED 
is red from green.
(2) Check following
Is the Power Board
normal ?
Replace Power
Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is the each connector
normal?
Replace the
connector.
Replace
Y-Board.
After connecting well each connector,
the normality it operates? 
Yes
No
No
Is the Ctrl Board
normal?
Replace
X-Board.
Is the output voltage normal after
remove P1, 2, 4, 9, 10 connector of
Ctrl-B/D?
Yes
No
Yes
Is the Y-Board
normal?
Is the output voltage
normal after remove
P5, P6 connector of
Y-B/D?
Is the Fuse(FS2) on Y-B/D normal?
(In case of open is replace)
Yes
No
Yes
Yes
Replace
Z-Board.
Is the Z-Board
normal?
Is the output voltage
normal after remove
P1 connector of Z-
B/D?
Is the Fuse (FS1, FS2) on Z-B/D
normal? (In case of open is replace)
Yes
No
Yes
Is the X- Board
normal?
Is the output voltage normal after
remove P1, 2, 3, 4, 5 connector of
X-B/D?
After remove P1, P2, P3 output voltage
normality: Replace Right X-B/D.
After remove P4, P5 output voltage
normality: Replace Left X-B/D.
Yes
No
Yes
Is the 
VSC Board normal?
Is the output voltage normal after
remove P1001, P1100?
After crisis COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is
replace the module.
After remove P1001, 1100 normal
operation: Replace VSC Board.
Yes
No
Is the COF of X, Y, Z
normal ?
No
Yes
Yes
- 23 -
4. No Raster
(1) Symptom
1) Doesn’t minute discharge at module. 
2) It maintains the condition where the front LED is green.
(2) Check following
Is the Power Board
normal?
Replace the
Power Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is the each connector
normal?
Replace the
connector.
Replace
Y-Board.
After connecting well each connector,
the normality it operates? 
Yes
No
No
Is the 
Ctrl Board normal?
Replace
X-Board.
Is the output voltage normal after
remove P1, 2, 4, 9, 10 connector of
Ctrl-B/D?
Yes
No
Yes
Is the Y-Board
normal?
Is the output voltage
normal after remove
P5, P6 connector of
Y-B/D?
Is the Fuse(FS2) normal on Y-B/D?
(In case of open is replace)
Yes
No
Yes
Yes
Replace
Z-Board.
Is the 
Z- Board normal?
Is normal the output
voltage after remove
P1 connector of 
Z-B/D?
Is the Fuse(FS1, FS2) normal on
Z-B/D? (In case of open is replace)
Yes
No
Yes
Is the 
X- Board normal?
Is the output voltage normal after
remove P1, 2, 3, 4, 5 connector of
X-B/D?
After remove P1, P2, P3 output voltage
normality: Replace Right X-B/D.
After remove P4, P5 output voltage
normality: Replace the Left X-B/D.
Yes
No
Yes
Is the 
VSC Board normal?
Is the output voltage normal after
remove P1001, P1100?
After crisis COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is
replace the module.
After remove P1001, P1100 normal
operation: Replace the VSC Board.
Yes
No
Is the COF of X, Y, Z
normal?
No
Yes
Yes
- 24 -
5. In case of occurring strange screen into specific mode
5-1. In case the OSD does not displayed
(1) Symptom
1) LED is green.
2) The minute discharged continuously becomes
Accomplished from module.
(2) Check following
Is the LVDS cable
normal ?
Is the VSC Board
normal?
Is the LVDS cable
connected well?
Cable inserts well.
Yes
No
No
Yes
Does the FIL8532 IC
(IC800) Operates ?
Replace FIL8532 IC
(IC800).
No
Is the Ctrl Board of
Module normal?
Replace Ctrl B/D.
No
No
Yes
Replace VSC B/D
Replace the cable.
Yes
Page of 59
Display

Click on the first or last page to see other 50PB2RR-TL (CHASSIS:MF-056L) service manuals if exist.