LG 50PB2DR-AC (CHASSIS:PB61C) Service Manual ▷ View online

- 13 -
6. Video(uPD)- Set Adjustment
6-1. Synopsis
This is a adjustment to reduce the color difference of video
signal Main/Sub Display.
6-2. Required Equipment
Service R/C, MSPG-925 Pattern Generator.
(It’s available to output the Color Bar Pattern of the NTSC,PAL)
6-3. Adjustment
(1) How to adjustment the uPD PAL
1) Select AV1 as the input with 100% 8 Color Bar Pattern
in PAL mode and select ‘AV1’ on screen. 
2) After receiving signal for at least 1 second, press the
ADJ Key on the Service R/C to enter the ‘Ez - Adjust’
and select the ‘4. uPD PAL AV(Main&Sub)-Set’.
Pressing the Vol+ Key to adjust the uPD PAL.  
3) When the adjustment is over, 'PAL-AV uPD ADC
Success’ is displayed. If the adjustment has errors,
'Video Configuration Error’ is displayed.
4) Readjust after confirming the case Pattern or adjustment
condition where the adjustment had errors. 
5) After adjustment is complete, exit the adjustment mode
by  pressing the ADJ KEY.
(2) How to adjustment the uPD NTSC
1) Select AV1 as the input with 100% 8 Color Bar Pattern
in NTSC mode and select ‘AV1’ on screen. 
2) After receiving signal for at least 1 second, press the
ADJ Key on the Service R/C to enter the ‘Ez - Adjust’
and select the ‘5. uPD NTSC AV(Main&Sub)-Set’.
Pressing the Vol+ Key to adjust the uPD NTSC.  
3) When the adjustment is over, 'NTSC-AV uPD ADC
Success’ is displayed. If the adjustment has errors,
'Video Configuration Error’ is displayed.
4) Readjust after confirming the case Pattern or adjustment
condition where the adjustment had errors. 
5) After adjustment is complete, exit the adjustment mode
by  pressing the ADJ KEY.
(3) How to adjustment the uPD RF-PAL
1) Input the PAL signal to Set antenna terminal, and select
input mode in ANALOG, and than verify if RF image
appears on screen.
2) After receiving signal for at least 1 second, press the
ADJ Key on the Service R/C to enter the ‘Ez - Adjust’
and select the ‘5. uPD NTSC AV(Main&Sub)-Set’.
Pressing the Vol+ Key to adjust the uPD NTSC.  
3) When the uPD RF adjustment is over, appears a
massage as
‘AUS RF uPD ADC Success’. If uPD RF
adjustment has errors, can appear 2 kinds of message,
if appears 
‘Check the signal status’, it means the
signal is not connected correctly, and verify if the signal
is connected correctly to the terminal of Set antenna. If
appears 
‘Video Configuration Error’, it means the
signal is connected correctly but the adjustment process
was wrong.
4) Readjust after confirming the case Pattern or adjustment
condition where the adjustment had errors. 
5) After adjustment is complete, exit the adjustment mode
by  pressing the ADJ KEY.
7. POWER PCB Assy Voltage
Adjustment
(Va, Vs Voltage Adjustment)
7-1. Test equipment:
D.M.M 1EA
7-2. Connection Diagram for Measuring
Refer to Fig.5
7-3. Adjustment Method 
Adjustment Method for Power Board( P/No: 6709900020B)
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M to Va pin of P805, connect
- terminal to GND pin of P805.
3) After turning VR901, voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top.
(Deviation; ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of 805, connect –
terminal to GND pin of P805.
2) After turning VR951, voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top.
(Deviation; ±0.5V)This is the function that enables “Plug
and Play".
(3) 3.3V Adjustment
1) Connect + terminal of D.M.M to Vs pin of 803, connect –
terminal to GND pin of P803.
2) Move UR221 to set the voltage value of D.M.M between
3.36V and 3.4V.
(Fig. 3) Adjust Pattern :100% 8 Color Bar Pattern
Each PCB Assy must be checked by Check JIG Set before
assembly. (Especially, be careful Power PCB Assy which can
cause Damage to the PDP Module.)
(Fig. 5) Connection Diagram of Power Adjustment for Measuring
- 14 -
8EDID(The Extended Display 
Identification Data)/DDC
(Display Data Channel) Download
8-1. Required Test Equipment
(1) PC, Jig for adjusting DDC.
(PC serial to D-sub  Connection equipment)
(2) DVI to HDMI Connector.
8-2. Setting of Device
8-3. EDID DATA
<EDID Checksum >
- 50PB2DR-AC
HDMI PORT1 : 61   45
HDMI PORT2 : E6  18
RGB : DB
(1) HDMI/DVI Port1 EDID DATA.
(2) HDMI Port2 EDID DATA.
(3) RGB EDID DATA.
8-4. Act or set the EDID S/W
(1) As above Fig. 6, Connect the Set, EDID Download Jig, PC
& Cable.
(2) Turn on the PC & EDID Download Jig. And Execute the
S/W : EDID TESTER Ver,2.5.
(3) Set up S/W option.
Repeat Number : 3
Device Address : A0
PageByte : 8
PC
JIG
PDP
SET
61
61
45
45
DB
E6
E6
18
18
Analog EDID
D-sub to D-sub
HDMI EDID
DVI-D to HDMI
- 15 -
8-5. How to use the EDID S/W
(1) Init the data.
(2) Load the EDID data.(Open File)
(3) Press the “Write Data & Verify”button. and input the data.
(4) If the writing is finished, you will see the “OK” message.
9. Adjustment of White Balance
9-1. Required Equipment
(1) Color analyzer : CA-100+ (CH10) or CA-100 (CH10) 
: When adjust the color temperature of Plasma, the Color
analyzer (CA-100+, CA-100) must use channel 10 that is
adjusted in Matrix adjusted by CS-1000 (White, Red,
Green, Blue adjusted) and adjust according to white
balance coordinates as below. 
(2) Automatic adjustor (with automatic adjustment hour
necessity and the RS-232C communication being possible)
9-2.  Connection Diagram of Equipment 
for Measuring 
(Automatic Adjustment)
(1) Connection Diagram
: Adjusted W/B using inside Pattern. When connecting to
Auto-controller, or pressing R/C ADJ to enter to Ez Adjust
8.White-Balance appears the Pattern automatically.
(2) Condition for automatic adjustment and attentions
1) Apply the adjustment where the illuminance is less than
10 lux, it means in a place controlled in maximum the
indraft of light.
2) Adjust/measure with the Color Analyzer ( CA-100+, CA-
100 ) contacting completely in the surface of Module.
(3) Aging time
1) After Aging start, make Heat-run more than 15 min. (in
power on status)
2) In case of PDP, maintain Full white Pattern using
internal pattern.
(4)  Process of automatic adjustment
1) As using the white pattern for adjustment the inner part,
HDMI connection need not. But as lower part, the RS-
232C Command is used.
Wb 00 00  Automatic adjustment of white balance start. 
Wb 00 10  The start of gain adjustment.(inside pattern)
Ja   00  ff   Adjustment Date.
Jb   00 c0
...
Wb 00 1f   The end of gain adjustment.
As occasion demands , adjust the offset.
( Wb 00 20(Start) , Wb 00 2f(end))
Wb 00 ff    Automatic adjustment of white balance end.
(Disappear the inside pattern)
[
[
Caution)
RS-232C Command
(Automatic Adjustment)
9-3. Adjustment of White Balance
(Automatic Adjustment)
(1) Color analyzer : CA-100+ (CH10) or CA-100 (CH10) 
: When adjust the color temperature of Plasma, the Color
analyzer (CA-100+, CA-100) must use channel 10 that is
adjusted in Matrix adjusted by CS-1000 (White, Red,
Green, Blue adjusted) and adjust according to white
balance coordinates as below. 
(Inside Pattern)
<Fig. 6>  Connection Diagram of Automatic Adjustment
R Gain
G Gain
B Gain
R Offset
G Offset
B Offset
CENTER
(DEFAULT)(Hex)
00
00
00
C0
C0
C0
Min
Max
(Hex)
40
40
40
Cool
40
40
40
Mid
40
40
40
Warm
RS-232C COMMAND
[CMD ID DATA]
Jg
Jh
Ji
Cool
Ja
Jb
Jc
Mid
Jd
Je
Jf
Warm
- 16 -
9-4. Adjustment of White Balance
(Passivity Adjustment)
(1) Enter to ‘EZ-ADJUST’ by pressing ADJ key of R/C.
(2) HEAT RUN at least 30 minutes by pressing the ‘11. TEST
Pattern’ on the Service Remote Control and adjust.
(3) Set CA-100+ (CH 10) OR CA-100 (CH 10) in Zero
Calibration, when adjust PDP module make it contacting
completely in the surface.
(4) Select ‘8. White-Balance’ of ‘Ez - Adjust’ by pressing the
ADJ KEY on the Service R/C. Then enter adjustment mode
by pressing the Right KEY (G). This time white pattern is
displayed. (When press  Gkey, the screen enters to Full
White internal pattern.)
(5) The adjustment completes in three color temperatures as
Cool, Medium, and Warm. ( R/G/B OFFSET=64 fix)
1) When R GAIN is fixed at 192:
keep G GAIN and B GAIN less than 192 and find proper
values for adjustment.
2) When G GAIN is fixed at 192:
keep R GAIN and B GAIN less than 192 and find proper
values for adjustment.
3) When B GAIN is fixed at 192:
keep R GAIN and G GAIN less than 192 and find proper
values for adjustment.
(6) Adjust using Volume +/- KEY.
Value of bright : High Level -> 216gray
[Cool]
Color coordinates : X; 0.277 ± 0.002 Y; 0.281 ± 0.002
Color temperature : 11000°K      uv: 0.000
[Medium]
Color coordinates : X; 0.286 ± 0.002 Y; 0.291 ± 0.002
Color temperature : 9300°K      uv: 0.000
[Warm]
Color coordinates : X; 0.315 ± 0.002 Y; 0.322 ± 0.002
Color temperature: 6500°K      uv: 0.000
(7) Move the the Ez-Adjust screen by pressing the  
V
KEY
and exit the adjustment mode by  pressing the ADJ KEY.
[Ref.] White Balance Adjustment Pixel and Color Temperature
(1) When CS-1000 is available:
(2)CA-210 indication value (CH 10)
(3)CA-100/100+ indication value (CH 10)
10. How to Download Software
- How to Use RS-232C to Download S/W via Serial port.
10-1. S/W Download Program
(1) Use DTV Lab.
10-2.  Set up the Network Configuration of
the Program for successful download.
(1) Click “Set Property” and set the values as shown in the
following picture.
(2) Set Com Port to Serial Port and Baud Rate to 115200.
(3) Press OK to exit the Configuration.
(4) Connect PC and DTV via Serial Port and turn on the TV.
(5)  Press “Connect”. The button will change to “Disconnect.”
Put cursor on the DTV Lab window and press Keyboard to
see the input appear in the window. If it works, the DTV is
successfully connected to computer.
COOL
MIDIUM
WARM
T=11000K,     uv: 0.000
T=  9300K,     uv: 0.000
T=  6500K,     uv: 0.000
x=0.276 y=0.283
x=0.285 y=0.293
x=0.314 y=0.324
Color Temperature
Color Coordinate
Color Temperature
Color Coordinate
Measuring instrument
x
0.283±0.002
0.293±0.002
0.324±0.002
0.276±0.002
0.285±0.002
0.314±0.002
COOL
MIDIUM
WARM
11000°K,     uv: 0.000
9300°K,     uv: 0.000
6500°K,     uv: 0.000
Color Temperature
Color Coordinate
Measuring instrument
x
0.283±0.002
0.293±0.002
0.324±0.002
0.276±0.002
0.285±0.002
0.314±0.002
COOL
MIDIUM
WARM
11000°K,     uv: 0.000
9300°K,     uv: 0.000
6500°K,     uv: 0.000
50X3, 40%filter ]
Color Temperature
Color Coordinate
Measuring instrument
x
0.281±0.002
0.291±0.002
0.322±0.002
0.276±0.002
0.285±0.002
0.314±0.002
COOL
MIDIUM
WARM
11000°K,     uv: 0.000
9300°K,     uv: 0.000
6500°K,     uv: 0.000