Notice : From this sentence, All working is mass production.
8. POWER PCB Assy Voltage
Adjustment
(Vs voltage Adjustment)
8-1. Test Equipment:
D.M.M 1EA
8-2. Connection Diagram for Measuring
Refer to (Fig. 4)
8-3. Adjustment Method 
(1) Vs Adjustment
1)  Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P702,
connect -terminal to GND pin of P702.
2)  After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top  (
deviation ; ±0.5V)
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment 
of the Color Temperature
(1)  Purpose:  Adjust  the  color  temperature  to  reduce  the
deviation of the module color temperature.
(2)  Principle  :  To  adjust  the  white  balance  without  the
saturation,  Fix  the  one  of  R/G/B  gain  to  C0  and  decrease
the others.
(3) Adjustment mode: Two modes of Cool, Warm and Medium
9-2. Required Equipment
(1) Remote controller for adjustment 
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
[ Notice:  When  using  the  Color  Analyzer  with  PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB) 
(5) Pattern Generator (MSPG-925FA etc.)
-Before  white  balance,  press  the  ADJ  key  and  select  third
row like (Fig. 5)
-To enter White-balance mode, Enter Password Number “0
0 0 0” and  select third row. 
[ Caution: System control Host should be “DDC” for adjustment.
(6) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
9-3. Connecting Diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(Method 2, using RS-232C, You connect RS-232C Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run  mode  when  pushing  the  power  on  by  power  only
key
- 13 -
P811
Vs ADJ
VR901
(Fig. 4)
EZ ADJUST
0. ADC CALIBRATION  : TV
1. ADC ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN   : OFF
5. EDID D/L
(Fig. 5)
3. W/B ADJUST
ModeVVV
: TV
TEMPERATUREVV
: Medium
R-Gain.VVV
: 192
G-Gain.VVV
: 192
B-Gain.VVV
: 192
R-OffsetVVV
: 128
G-OffsetVVV
: 128
B-OffsetVVV
: 128
COPY ALL
(Fig. 6)
Method 2-(RS-232C)
-  Maintain  the  white  balance  adjustment  mode  with  same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
-  Release  the  adjust  mode  after  AC  off/on  or  std-by  off/on  in
status of finishing the Hear-run mode
-  Release  the  Adjust  mode  when  receiving  the  aging  off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
-  Enter  the  white  balance  adjustment  mode  with  aging
command(F3, 00, FF)
9-4. Adjustment of White Balance for 
Manual Adjustment
(method 3) 
Adjustment  mode:  Three  modes  of  Cool,  Medium(Vivid)  and
Warm
- Equipment : 1) Color analyzer(CA100+, CA210) should be
used  in  the  calibrated  ch  by  CS-1000(PDP  :
CH10)
2) Adjustment remocon
-  For  manual  adjustment,  it  is  also  possible  by  the  following
sequence.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
(1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 5 minutes. (recommend) 
(If  not  executed  this  step,  the  condition  for  W/B  will  be
different)
(2)  Changing  to  the  AV  mode  by  remote  control.(Push  front-
AV)
(3) Input external pattern(85% white pattern).
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue  Gain  and  Offset)  using 
D
/
E
(CH  +/-)  key
on R/C..
(5) Adjust R/ G/ B Gain using 
F
/
G
(VOL +/-) key on R/C.
(6)  Adjust  three  modes  of  Cool,  Medium(Vivid)  and  Warm  as
below figure.
(Fix the one of R/G/B and change the others)
- Push the “VOL + “ key : Cool, Medium, Warm
[ Refer to the below case to know what value is fixed.
[CASE]
First adjust the coordinate much away from the target value(x, y).
1. x, y > target
1) Decrease the R, G. 
2. x, y < target
1) First decrease the B gain, 
2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
3. x > target ,  y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
4. x < target ,  y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
(7)  When  adjustment  is  completed,  Exit  adjustment  mode
using EXIT key on R/C.
9-5. Connecting diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(method 1, using IIC, You connect RGB Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run  mode  when  pushing  the  power  on  by  power  only
key
-  Maintain  the  white  balance  adjustment  mode  with  same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
-  Release  the  adjust  mode  after  AC  off/on  or  std-by  off/on  in
status of finishing the Hear-run mode
-  push  the  “power  on”  key(IIC  Mode)  on  Adjust  remote-
controller.
-  Release  the  Adjust  mode  when  receiving  the  aging  off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
-  Enter  the  white  balance  adjustment  mode  with  aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
-  When  adjusting  the  Color  Temperature,  Color  Analyzer  CA-
210(Matrix  should  be  corrected  through  CH10  of  CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
-  Adjust  the  Color  Temperature  based  below  adjustment  color
coordinates.
O
Target Value CA-210(LCD : CH 9, PDP : CH10), CA-100(PDP)
- 14 -
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276±0.002
0.285±0.002
0.293±0.002
0.329±0.002
0.313±0.002
0.283±0.002
Y
X
uv
Temp
Color coordinate
Mode
Method 1-(I
2
C)
(Standard  color  coordinate  and  temperature  when  using  the
CA-100+ or CA210 equipment)
O
Above  optical  characteristics  are  should  be  measured  by
following condition.
- 15 -
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276±0.002
0.285±0.002
0.293±0.002
0.329±0.002
0.313±0.002
0.283±0.002
Y
X
uv
Temp
Color coordinate
Mode
O
DDC Adjustment Command Set 
[ R/G/B GAIN max value : C0
Adjustment
Adjustment
Adjustment
- 16 -
BLOCK DIAGRAM
Page of 70
Display

Click on the first or last page to see other 42PQ301R-ZB (CHASSIS:PP91B) service manuals if exist.