DOWNLOAD LG MH-685HD Service Manual ↓ Size: 2.4 MB | Pages: 28 in PDF or view online for FREE

Model
MH-685HD
Pages
28
Size
2.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Microwave Oven
File
mh-685hd.zip
Date

LG MH-685HD Service Manual ▷ View online

5-10
COMPONENTS TEST 
PROCEDURE  RESULTS
HIGH VOLTAGE
CAPACITOR
Antenna
Gasket
Filament
Terminals
Chassis
Normal : Momentary indicates
several ohms, and
then gradually
returns to infinite.
Normal : 
infinite
NOTE : When testing the magnetron, be sure to install the magnetron gasket in
the correct position and be sure that the gasket is in good condition. 
Measure the resistance.
(Multi-meter scale : Rx1000) 
• Terminal to termonal.
Measure the resistance.
(Multi-meter scale : Rx1000) 
• Terminal to case.
Measure the continuity (Forward).
(Multi-meter scale : Rx10000) 
Measure the continuity (Reverse).
(Multi-meter scale : Rx10000) 
Normal : 
infinite
Abnormal : Continuity.
Normal : Continuity.
Abnormal : 
infinite
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive
meter may indicate
infinite resistance in
both direction.
5-11
COMPONENTS TEST 
PROCEDURE 
RESULTS
HEATER ELEMENT
(Wire leads removed)
FUSE
(Wire leads removed.)
Normal
Abnormal
0°c~Approx 150°C
Approx 150°C
OVEN THERMOSTAT
MAGNETRON
THERMOSTAT
Normal : 
• Grill heater
Approx. 40.7 
(at 20~30°C)
Normal : more than 0.5M 
Measure the resistance with 500V-100M
insulation resistance meter.
Measure the resistance.
(Multi-meter scale : Rx1) 
Check for continuity of the switch with a
Multi-meter.
NOTE : If the fuse is blown, check the primary, the secondary, and the monitor
switches, H.V.D. and H.V.C. before replacing the fuse.
If the fuse is blown by improper switch operation replace the defective
switch and the fuse at the same time.
Replace just the fuse if the switches operate normally.
NOTE : Make sure heater is fully cooled when tested.
5-12
COMPONENTS TEST 
PROCEDURE 
RESULTS
RELAY 1,2, OF P.C.B
(Disconnect the 7 pin 
connector from P.C.B)
See Schematic Dagram on
page 11)
RY1 : Turn Table, 
Fan Motor, 
Roti-Motor
Oven Lamp 
RY2 : Heater Moving Motor
RELAY 4, 5 OF P.C.B
(Wire leads removed.)
RY4 : Grill
RY5:: Microwave
KEY PAD
Check continuity between
switch terminals, by pressing an
appropriate pad on key board.
The contacts assignment of the
respective pads on the key
board is as shown left figures.
Cooking Start
OFF
CN2
1
3
5
7
Relay 1
Relay 2
Relay 4
Relay 5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
P.C.B
Tact S/W
Cooking Start
OFF
NOTE : A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
MAKE SURE THE WIRE LEADS ARE CORRECT POSITION.
WHEN REMOVING THE WIRE LEAD FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Trouble Shooting Guide
5-13
CAUTIONS
1. Check grounding before checking for other trouble.
2. Be careful of the high voltage circuit.
3. When checking the continuity of the switches or transformer, disconnect one lead wire from these parts and
then check continuity without turning the power source on.
4. Do not touch any part of the circuitry on the control circuit board, since static electric discharge may damage
this control circuit.
Always touch yourself to ground while working on this circuit to discharge any static charge built up in your
body.
5. First operate the microwave oven following the correct operating.
6. If the oven become inoperative because of a fuse, check the primary, the secondary and the monitor switches
before replacing the fuse.
CONDITION
The fuse blows when power
cord is plugged into wall
receptacle.
Shorted lead wise assy or
wire hardness.
Defective monitor switch or
out of adjustment.
Test procedure switches.
": 0" does not appear in 
displasy window when
power cord is first plugged
into wall outlet.
Microwave oven plug is not
inserted tightly.
No power at outlet.
Check home fuse.
Replace or repair wiring.
Test procedure tact switch
key.
Defective tact switch key of
P.C.B.
Display does not operate
properly when CLOCK is
touched.
Open wire in power cord,
wiring harness, or wiring
between control panel
assembly units.
Insert microwave oven plug
securely.
Replace lead wire or check
and repair wire hardness.
CAUSE
TEST PROCEDURE OR
CORRECTION
Blown fuse.
Test procedure fuse.
(TROUBLE 1) Oven does not operate all.
OFF CONDITION
Page of 28
Display

Click on the first or last page to see other MH-685HD service manuals if exist.