LG LWM1560BHE / LWM1861BHE / LWM1861BHG / LWN1862BHG / LWN2262BHG Service Manual ▷ View online
Is setting
Temp. set lower than Room
Temp.-0.5
°
C?
Is the voltage No.10
of IC01M 0V?
• Exchange IC01M.
• Select the setting Temp. to lower Number.
• Wait 3 Minutes.
Is the Unit for 3 minutes
delay?
• Exchange MAIN
PCB Ass'y.
PCB Ass'y.
Is the voltage N0.7 of
IC01M DC 5V?
• Check the RY-COMP.
• Check the wiring
Diagram.
Diagram.
NO
NO
NO
YES
YES
YES
YES
Is the wire connection of
RY-COMP all right?
• Check the RY-COMP.
• Connect LEAD Wire to
RY-COMP again.
RY-COMP again.
NO
YES
NO
—20—
Possible Trouble 2
The compressor does not operate.
Possible Trouble 3
The compressor always operate.
—21—
• Exchange IC01M.
• Exchange IC01M.
Is the voltage NO.2 or 3
of IC01M DC 5V?
Is the voltage NO.14 or 15
of IC01M 0V?
• Check the RY-Hi or
RY-Lo.
• Check the wiring diagram.
NO
NO
YES
YES
• Exchange Micom.
• Exchange IC01M.
• Check the PCB pattern.
Is the voltage NO.6
of IC01M DC 5V?
Is the voltage NO.11
of IC01M 0V?
• Check the RY-SYNC.
• Check the connectionn
of CN-SYNC.
• Check the connectionn
of CN-SYNC.
NO
NO
YES
YES
Possible Trouble 4
FAN does not operate.
Possible Trouble 5
Auto Swing does not operate.
—22—
NO
NO
NO
NO
YES
YES
YES
Is the IC01G all right?
Is the connection of
CN-DISP2 all right?
• Exchange the display
PCB Ass'y.
PCB Ass'y.
• Exchange IC01G.
• Exchange Q12G,
Q13G, Q14G.
Q13G, Q14G.
• Connect connector
to CN-DISP2 exactly.
to CN-DISP2 exactly.
Does the Q12G,
Q13G, Q14G operate normally
on main PCB Ass'y?
• Check the PCB pattern.
Is the voltage of Battery
about over 2.3V?
• Exchange Receiver Ass'y.
Is the connection of
CN-DISP2 all right?
Is the voltage No.10
of CN-DISP2 on Main PCB
Ass'y DC 5V?
• Exchange the battery.
• Check the PCB pattern.
• Connect connector to
CN-DISP2 exactly.
CN-DISP2 exactly.
NO
NO
NO
YES
YES
YES
Possible Trouble 6
Remote controller does not operate.
Possible Trouble 7
It displays abnormally on display PCB Ass'y.
—23—
NO
NO
YES
YES
Is the Knob of SW1
set to left position?
Is the voltage No.1 of
CN-DISP1 of Main PCB
Ass'y DC 5V?
• Reference to
OWNER'S MANUAL.
OWNER'S MANUAL.
• Set the Knob of SW1
to left position.
to left position.
• Check the SW1.
• Check the pattern of
Main & Display PCB.
• Check the pattern of
Main & Display PCB.
Possible Trouble 8
The function of Auto Restart does not operate.