4.2 PIPING SYSTEM
Following is a brief description of the important components and their function in what is called the refrigeration
system. Reference should made to Figure 29 to follow the refrigeration cycle and the flow of the refrigerant in the
cooling cycle.
Ñ
18
Ñ
MOTOR
COMPRESSOR
OIL
(LIQUID REFRIGERANT)
CAPILLARY TUBE 
OUTSIDE COOLING
AIR FOR REFRIGERANT
PASS THROUGH
SUCTION LINE
COOL LOW PRESSURE VAPOR
COOLED
AIR
COMPLETE LIQUID
BOIL OFF POINT
LIQUID
PRESSURE
DROP
ROOM AIR HEAT LOAD
VAPOR INLET
HOT
DISCHARGED
AIR
LIQUID OUTLET
HIGH PRESSURE VAPOR
LIQUID REFRIGERANT
LOW PRESSURE VAPOR
ROOM AIR CONDITIONER
EVAPORATOR COILS
CONDENSER COILS
CYCLE OF REFRIGERATION
Figure 29
CAPILLARY  TUBE
COMPRESSOR
BLOWER
EVAPORATOR  COIL
CONDENSER  COIL
FAN
MOTOR
:  COOLING CYCLE
:  HEATING CYCLE
4.3 TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two causes.
The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air
Conditioning caused by a defect in the refrigeration circuit and improper application.
Unit runs but poor cooling or heating.
Ñ
19
Ñ
Ineffective Cooling or Heating
Check of outdoor coil
(heat exchanger) & the fan
operation
Check gas leakage.
Repair gas leak.
Replacement of unit if the
unit is beyond repair.
Satisfactory operation with
temperature difference of
inlet & outlet air ;
COOLING :   7~10°C
HEATING  : 15~17°C
Check heat load increase in
cooling operation.
Unexpected residue
Added heat load
Check of inside gas
pressure
Adjusting of refrigerant
charge
Malfunction of compressor
Replacement of
compressor
Check of cold (warm) air cir-
culation for smooth flowing
Dirty indoor coil
(Heat exchanger)
Malfunction of fan
Clogged of air filter
Obstruction at air outlet
Countermeasure against
above trouble.
Check clogging in refrigera-
tion circuit.
Repair clogging in refrigera-
tion circuit.
Ñ
20
Ñ
Fails to start.
Check of circuit breaker
and fuse
Gas leakage of feeler bulb
of thermostat
Check of control switch
Only fan fails to start.
Improper wiring
Defect of fan motor
capacitor
Irregular motor resistance
(      )
Irregular motor insulation
(      )
Replacement of fan motor
Regular but fails to start.
Replacement of compressor
(locking of rotor, metal)
Improper thermostat setting
Loose terminal connection.
Improper wiring
Irregular motor resistance (    )
Irregular motor insulation (    )
Replacement of compressor
(Motor damaged)
Drop of power voltage
Capacitor check
Replacement
Only compressor fails to
start.
Defect of compressor
capacitor
Check of power source
Check of control switch
setting
Ñ
21
Ñ
Electrical Parts Troubleshooting Guide (LW-C0961HL/C1261HL)
Possible Trouble 1
The unit does not operate.
Is the Trans output power
AC 220V?
Is the Trans output power
about AC 13V?
Is shorted the Trans. output?
Is output Voltage of IC2
DC 12V?
Is output Voltage of IC3
DC 5V?
Is the voltage No.20 of IC1
DC 5V?
Exchange Main PCB Ass'y.
Is the 
connection between
Main and Display 
all right?
Is the reset circuit all right?
(The No.16 of 
IC1 is 5V.)
• Check the Fuse.
• Check the wiring diagram.
• Check the Main 
  PCB pattern.
• Exchange the Trans.
• Exchange BD1.
• Exchange IC2.
• Exchange IC3.
• Exchange IC4, C07.
• Connect connector
  exactly.
• Check the PCB 
  pattern.
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
NO
YES