SERVICE MANUAL
CAUTION
-
BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
-
ONLY FOR AUTHORIZED SERVICE.
MODELS: LWC0961AHG/ABG/AHE
LWC0961PHG/PBG
—2—
1. PREFACE
1.1 SAFETY PRECAUTIONS................................2
1.2 INSULATION RESISTANCE TEST .................2
1.3 SPECIFICATIONS...........................................3
1.4 FEATURES......................................................4
1.5 CONTROL LOCATIONS .................................4
2. DISASSEMBLY INSTRUCTIONS
2.1 MECHANICAL PARTS ....................................6
2.1.1 FRONT GRILLE .....................................6
2.1.2 CABINET ................................................6
2.1.3 CONTROL BOX .....................................6
2.2 AIR HANDLING PARTS ..................................7
2.2.1 AIR GUIDE AND BLOWER ....................7
2.2.2 FAN ........................................................7
2.2.3 SHROUD ................................................8
2.3 ELECTRICAL PARTS......................................8
2.3.1 OVERLOAD PROTECTOR ....................8
2.3.2 COMPRESSOR......................................8
2.3.3 CAPACITOR...........................................9
2.3.4 POWER CORD ......................................9
2.3.5 THERMOSTAT .......................................9
2.3.6 ROTARY SWITCH .................................9
2.3.7 MOTOR ................................................10
2.3.8 REVERSING VALVE ASSY .................10
2.4 REFRIGERATION CYCLE ............................11
2.4.1 CONDENSER.......................................11
2.4.2 EVAPORATOR.....................................11
2.4.3 CAPILLARY TUBE ...............................11
3. INSTALLATION
3.1 SELECT THE BEST LOCATION...................14
3.2 CHECK OF INSTALLATION..........................14
3.3 HOW TO DRAIN............................................14
3.4 HOW TO ATTACH DRAIN PAN ....................14
3.5 HOW TO INSTALL ........................................15
3.6 HOW TO USE THE REVERSIBLE
INLET GRILLE...............................................16
4. TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS ...............................17
4.2 PIPING SYSTEM...........................................17
4.3 TROUBLESHOOTING GUIDE ......................18
5. SCHEMATIC DIAGRAM
5.1 CIRCUIT DIAGRAM ......................................27
5.2 DEICER P.C.B ASSY ....................................28
5.3 ELECTRONIC CONTROL DEVICE...............29
5.4 COMPONENTS LOCATION
(OF MAIN P.C.B ASSY) ................................30
5.5 COMPONENTS LOCATION
(OF DISPLAY P.C.B ASSY) ..........................30
6. EXPLODED VIEW AND
REPLACEMENT PARTS LIST
........31
1. PREFACE
This
SERVICE MANUAL
provides various service information, including the mechanical and electrical
parts etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
1. When servicing the unit, set the ROTARY SWITCH
or POWER SWITCH to OFF and unplug the power
cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing the unit, make an insulation resis-
tance test to protect the customer from being
exposed to shock hazards.
1.2 INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (green) is to be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all the positions
(except OFF) of the ROTARY SWITCH.
4. The value should be over 1M
.
CONTENTS
—3—
POWER SUPPLY
CAPACITY
(BTU/h)
INPUT
(W)
COOLING
RUNNING CURRENT (A)
E.E.R
(BTU/W.h)
CAPACITY
(BTU/h)
INPUT
(W)
HEATING
RUNNING CURRENT (A)
E.E.R
(BTU/W.h)
COOLING
INDOOR
(°C)
OUTDOOR (°C)
HEATING
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING/HEATING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
1ø, 220V-240V~,50Hz
9,000
1,000
4.4
9.0
9,000
920
4.0
9.8
27 (DB)* 19 (WB)**
35 (DB)
24 (WB)
20 (DB)
15 (WB)
7 (DB)
6 (WB)
600g (21.2Oz)
2ROW 16STACKS, S-FIN TYPE
2ROW 17STACKS, LOUVERED-FIN TYPE
TURBO FAN
PROPELLER TYPE FAN WITH SLINGER-RING
1/2/2
2/2/2
6 POLES
ROTARY SWITCH
WIRELESS REMOCON
THERMOSTAT
THERMISTOR
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.8m (7") (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PAN OR SPLASHED BY FAN SLINGER
97/44
97/44
23
5
/
8
x 14
31
/
32
x 21
7
/
8
600 x 380 x 555
LWC0961AHG/ABG/AHE
LWC0961PHG/PBG
MODELS
ITEMS
OPERATING
TEMPERA-
TURE
* DB:Dry Bulb
** WB:Wet Bulb
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving performance.
1.3 SPECIFICATIONS
—4—
1.4 FEATURES
• Designed for HEAT PUMP.
• Powerful and whispering cooling & heating
• Slide-in and slide-out chassis for the simple
installation and service.
• Side air-intake, side cooled-air discharge.
1.5 CONTROL LOCATIONS
• VENTILATION
The ventilation lever must be in the CLOSE position
in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever OPEN position.
The damper is opened and room air is exhausted.
• Built-in adjustable THERMOSTAT
• Washable one-touch filter
• Compact size
• Reliable and efficient rotary compressor is equipped.
• HEATER LAMP
When the unit sets heating operation condition, the
green lamp is lighted.
When the frost settles on the heat exchanger of the
outside, defrosting is made automatically and the
green lamp is unlighted. The until it may hiss and
the fan motor will stop for 1 to 10 minutes.
This should not be regarded as trouble. After
defrosting, the heating operation begins again.
• THERMOSTAT
Turn the thermostat control to the desired setting.
The central position is a normal setting for average
conditions. You can change this setting, if
necessary, in accordance with your temperature
preference.
The thermostat automatically controls cooling or
heating, but the fan runs continuously whenever
the air conditioner is in operation. If the room is
too warm, turn the thermostat control clockwise. If
the room is too cool, turn the themostat control
counterclockwise.
• OPERATION
OFF
(
) : Turns the air conditioner off.
LOW FAN
(
) : Permits the low fan speed
operation without cooling
(or heating).
LOW COOL (
) : Permits cooling with the low
fan speed operation.
HIGH COOL (
) : Permits cooling with the high
fan speed operation.
LOW HEAT (
) : Permits heating with the low
fan speed operation.
HIGH HEAT (
) : Permits heating with the high
fan speed operation.
(TYPE1)
(TYPE2)
0
THERMOSTAT
OPERATION
COOLER
WARMER
HEATER
COO
L
H
EA
T
Thermostat
Warmer
Cooler
Heater
Operation
Page of 35
Display

LG LWC0961AHG_ABG_AHE / LWC0961PHG_PBG / W09LH Service Manual ▷ Download

  • DOWNLOAD LG LWC0961AHG_ABG_AHE / LWC0961PHG_PBG / W09LH Service Manual ↓ Size: 1.58 MB | Pages: 35 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LWC0961AHG_ABG_AHE / LWC0961PHG_PBG / W09LH in PDF for free, which will help you to disassemble, recover, fix and repair LG LWC0961AHG_ABG_AHE / LWC0961PHG_PBG / W09LH Air Conditioner. Information contained in LG LWC0961AHG_ABG_AHE / LWC0961PHG_PBG / W09LH Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.