1. PREFACE
1.1 SAFETY PRECAUTIONS
2
1.2 INSULATION RESISTANCE TEST
2
1.3 SPECIFICATIONS
3
1.4 FEATURES
4
1.5 CONTROL LOCATIONS
4
2. DISASSEMBLY INSTRUCTIONS
2.1 MECHANICAL PARTS
6
2.1.1 FRONT GRILLE
6
2.1.2 CABINET
6
2.1.3 CONTROL BOX
6
2.2 AIR HANDLING PARTS
7
2.2.1 AIR GUIDE
7
2.2.2 BLOWER
7
2.2.3 FAN
7
2.2.4 SHROUD
8
2.3 ELECTRICAL PARTS
8
2.3.1 OVERLOAD PROTECTOR
8
2.3.2 COMPRESSOR
8
2.3.3 CAPACITOR
9
2.3.4 POWER CORD
9
2.3.5 THERMOSTAT
9
2.3.6 ROTARY SWITCH
9
2.3.7 MOTOR
10
2.3.8 REVERSING VALVE ASSY
10
2.4 REFRIGERATION CYCLE
11
2.4.1 CONDENSER
11
2.4.2 EVAPORATOR
11
2.4.3 CAPILLARY TUBE
11
3. INSTALLATION
3.1 SELECT THE BEST LOCATION
14
3.2 WINDOW REQUIREMENTS
14
3.3 INSTALLATION KITS CONTENTS
14
3.4 SUGGESTED TOOL REQUIREMENTS
15
3.4.1 PREPARATION OF CHASSIS
15
3.4.2 CABINET INSTALLATION
15
4. TROUBLESHOOTING GUIDE
4.1 OUTSIDE DIMENSIONS
17
4.2 PIPING SYSTEM
18
4.3 TROUBLESHOOTING GUIDE
19
5. SCHEMATIC DIAGRAM
5.1 CIRCUIT DIAGRAM
29
5.2 DEICER P.C.B. ASSY
33
5.3 ELECTRONIC CONTROL DEVICE
34
5.4 COMPONENTS LOCATION OF MAIN P.C.B ASM
35
5.5 COMPONENTS LOCATION OF DISPLAY P.C.B ASM
35
6. EXPLODED VIEW
36
7. REPLACEMENT PARTS LIST
37
1. PREFACE
This 
service manual
provides various service information, including the mechanical and electrical parts etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 SAFETY PRECAUTIONS
1. When servicing the unit, set the ROTARY SWITCH
or POWER SWITCH to OFF and unplug the power
cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing the unit, make an insulation resis-
tance test to protect the customer from being
exposed to shock hazards.
1.2 INSULATION RESISTANCE TEST
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (GN/YL) is to be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all the positions
(except O/OFF) of the ROTARY SWITCH.
4. The value should be over 1M
.
CONTENTS
Ñ
2
Ñ
1.3 SPECIFICATIONS
* DB : dry bulb
** WB : wet bulb
Ñ
3
Ñ
POWER SUPPLY
CAPACITY
(BTU/h)
INPUT
(W)
COOLING
RUNNING CURRENT (A)
E.E.R
(Btu/w.h)
CAPACITY
(BTU/h)
INPUT
(W)
HEATING
RUNNING CURRENT (A)
E.E.R
(BTU/W.h)
COOLING  
INDOOR
(°C)
OUTDOOR (°C)
HEATING 
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING/HEATING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W 
¡¿
H  
¡¿
D)
(mm)
9,000
11,500
10,700/11,000
1,000
1,350
1,255/1,290
4.4
5.7
6.0/5.7
9.0
8.5
8.5
9,000
11,500
10,100/10,500
920
1,150
1,085/1,130
4.0
4.8
5.3/5.0
9.8
10
9.3
27 (DB)*   19.5 (WB)**
26.7 (DB)  19.4 (WB)
35 (DB)    24 (WB)
35 (DB)  23.9 (WB)
21 (DB)    15.5 (WB)
21.1 (DB)  15.5 (WB)
7 (DB)    6 (WB)
8.3 (DB) 6.1 (WB)
740g (26.1Oz)
720g (25.4Oz)
700g (24.7Oz)
2 ROW 13 STACKS, LOUVERED-FIN TYPE
2 ROW 14 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
1/2/2
2/2/2
1/2/2
2/2/2
1/2/2
6 POLES
ROTARY SWITCH WIRELESS REMOCON ROTARY SWITCH WIRELESS REMOCON
ROTARY SWITCH
THERMOSTAT
THERMISTOR
THERMOSTAT
THERMISTOR
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.8m (7") (3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PAN OR SPLASHED BY FAN SLINGER
95/43
95/43
99/45
99/45
95/43
23
5
/
8
"
¡¿
14
31
/
32
"
¡¿
21
27
/
32
"
600 
¡¿
380 
¡¿
555
1ø, 220V-240V~,50Hz
1ø, 208/230V~, 60Hz
LW-C0960HL LW-C0961HL
LW-C1260HL
LW-C1261HL
LW-C1232HL
MODELS
ITEMS
OPERATING
TEMPERA-
TURE
1.4 FEATURES
• Designed for cooling or heating
• Powerful and quiet cooling
• Slide-in and slide-out chassis for the simple
installation and service
• Side air-intake, side cooled-air discharge
1.5 CONTROL LOCATIONS
1.5.1 CONTROL ONLY MODEL
• VENTILATION
The ventilation lever must be CLOSE position in
order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever to the OPEN position.
The damper is opened and room air is exhausted.
• HEATER (    ) LAMP
When the unit sets heating operation condition, the
green lamp is lighted.
When the frost settles on the heat exchanger of the
outside, defrosting is made automatically and the
green lamp is unlighted. The until it may hiss and
the fan motor will stop for 1 to 10 minutes.
This should not be regarded as trouble. After
defrosting, the heating operation begins again.
• THERMOSTAT
Turn the thermostat control to the desired setting.
The centrol position is a normal setting for average
conditions. You can change this setting, if
necessary, in accordance with your temperature
preference.
The thermostat automatically controls cooling or
heating, but the fan runs continuously whenever
the air conditioner is in operation. If the room is
too warm, turn the thermostat control clockwise. If
the room is too cool, turn the themostat control
counterclockwise.
• OPERATION
OFF
(       ) : Turns the air conditioner off.
LOW FAN
(       ) : Permits the low fan speed 
operation without cooling (heating).
FAN
: Permits the MED fan speed 
operation without cooling (heating).
LOW COOL (       ) : Permits cooling with the low
fan speed operation.
HIGH COOL (       ) : Permits cooling with the high 
fan speed operation.
LOW HEAT  (       ) : Permits heating with the low 
fan speed operation.
HIGH HEAT (       ) : Permits heating with the high 
fan speed operation.
• Built in adjustable THERMOSTAT or
THERMISTOR.
• washable one-touch filter.
• Compact size.
• Reliable and efficient rotary compressor is
equipped.
Ñ
4
Ñ
CLOSE
VENT
OPEN
COOLER
(TYPE1)
(TYPE2)
(TYPE3 )
HEATER
THERMOSTAT
OPERATION
THERMOSTAT
OPERATION
WARMER
COOLER
WARMER
HEATER
LOW
FAN
LOW
HEAT
HIGH
HEAT
HIGH
COOL
LOW
COOL
LOW
FAN
COOL
HE
AT
FAN
FAN
OFF
LOW
LOW
HIGH
HIGH
BEFORE RESTARTING
WAIT THREE MINUTES
Ñ
5
Ñ
FAN SPEED
TEMP
POWER
MODE
SLEEP
FAN
COOL
DEFROST
HEAT
ON
ON
OFF
AUTO RESTART
• DISPLAY COOL/HEAT/FAN/DEFROST
It indicates COOL/HEAT/FAN/DEFROST.
• SLEEP
It displays the operating of timer.
• REMOCON SIGNAL RECEIVER
• OPERATION SWITCH
When you cannot using Remote
Controller, push this button. 
When you first turn on, High Cool mode
and 19°C are set automatically 
(If Indoor Temp. not less than 21°C),
however High Heat mode and 23°C set
(If Indoor Temp. less than 21°C).
• AUTO RESTART
In failure of electricity, if the switch is set to
"ON", the unit runs as previous setting
operation when power returns.
• TEMPERATURE SETTING
This button can automatically control the
temperature of the room. The temperature
can be set within a range of 16°C to 30°C
by 1°C. 
• FAN SPEED
Everytime you push this button, it is set
as follows.
(High 
Low 
High ...)
1.5.2 HEAT PUMP MODEL WITH REMOTE CONTROL AND TOUCH TYPE
Page of 37
Display

LG LW-C0961HL Service Manual ▷ Download

  • DOWNLOAD LG LW-C0961HL Service Manual ↓ Size: 1.03 MB | Pages: 37 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LW-C0961HL in PDF for free, which will help you to disassemble, recover, fix and repair LG LW-C0961HL Air Conditioner. Information contained in LG LW-C0961HL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.