DOWNLOAD LG LV-B1861CL / LV-B1861HL / LV-B1864CL / LV-B1864HL / LV-B2461CL / LV-B2461HL / LV-B2464CL / LV-B2464HL Service Manual ↓ Size: 2.36 MB | Pages: 63 in PDF or view online for FREE

Model
LV-B1861CL LV-B1861HL LV-B1864CL LV-B1864HL LV-B2461CL LV-B2461HL LV-B2464CL LV-B2464HL
Pages
63
Size
2.36 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lv-b2464hl.zip
Date

LG LV-B1861CL / LV-B1861HL / LV-B1864CL / LV-B1864HL / LV-B2461CL / LV-B2461HL / LV-B2464CL / LV-B2464HL Service Manual ▷ View online

–25–
Drain hose
Ceiling
Ceiling
Ceiling
Front of view
Side of view
1. Install declination of the indoor unit is very important for the drain of the convertible type air
conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 7mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined
to the bottomside.
CAUTION
• The unit must be horizontal or declined to the drain hose connected when finished installation.
• The unit must be declined to the bottomside of the unit when finished installation.
–26–
R
R
R
1
2
• Before working, refer to "Connecting pipe
   and cable to Indoor Unit" on page 32.
R
Inlet hanger
Hook
Cabinet Bottom
• Secure the unit to the Installation Plates with four M8
bolts and washers.
• Hook up the Inlet Grille Hook to the cabinet.
• Hang the Inlet Hanger to the screw.
• Fit the projection hooks of the side plates to the 'Side
Panel' and the 'Front Panel' by lifting it.
• Fasten the screws.
–27–
1076
more than
260
265
Washer
Nut
Wall
Anchor nut
Spring 
washer
Wall
5~7mm
Less than
12mm
1236
Indoor
Outdoor
2) Installation on the Wall
• Select and mark the position for fixing bolts and piping
hole.
Decide the position for fixing bolts slightly tilted to the
drain direction after considering the direction of drain
hose.
• Drill the hole for anchor nut on the wall.
• Drill the piping hole on the wall slightly tilted to the out-
door side using a ø70 hole-core drill.
• Secure the 'Install Plate' onto the wall with four anchor
bolts, washers and spring washers.
Before secure the Install Plates, select the bent direc-
tion of the 'Install Plate' to the inside or outside
according to the installation circumstances.
–28–
Install the Indoor unit onto Installation Plate.
• Insert 2 hooks on the both left and right side of the unit
to the inner slot (wall side) of the Installation Plate.
• Secure the unit to the Installation Plate with four M8
bolts and washers.
• Hook up the Inlet Grille Hook to the cabinet.
• Hang the Inlet Hanger to the screw.
• Fit the projection hooks of the side plates to the 'Side
Panel' and the 'Front Panel' by lifting it.
• Fasten the screws.
R
2
1
• Before working, refer to "Connecting pipe
   and cable to Indoor Unit" on page 32.
Inner slot
Page of 63
Display

Click on the first or last page to see other LV-B1861CL / LV-B1861HL / LV-B1864CL / LV-B1864HL / LV-B2461CL / LV-B2461HL / LV-B2464CL / LV-B2464HL service manuals if exist.