DOWNLOAD LG LS-P1260BB Service Manual ↓ Size: 2.37 MB | Pages: 55 in PDF or view online for FREE

Model
LS-P1260BB
Pages
55
Size
2.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-p1260bb.zip
Date

LG LS-P1260BB Service Manual ▷ View online

-52-
Exploded View and Replacement Parts List
1. Indoor Unit
359012
249951
264110
268714
135515
267110
135500-3
349600
135500-2
135311-2
146811
147581
330870
135311-3
146811
346810
135500-1
146811
135311-2
131410
352380
352150
35211B
263230
147581
152312
135303
135314
268712
268717
135312
354210
144710-2
146811
146811
144710-1
147581
352116
352115
2. Outdoor unit
-54-
554031
437212
435511
W0CZZ
552202
552116
552102-1
552201
554160
561410
550140
552203-1
552203-2
430410
447910
649950
552102-2
552111
437210
559010
546810
P/No.: 3828A20135F
February, 2002
Functions
• Room temperature sensor. (THERMISTOR)
• Maintains the room temperature in accordance with the Setting Temp.
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low, CHAOS
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), med(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed.
• The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
• Both the indoor and outdoor fan stops dur-
ing defrosting.
• The indoor fan stops until the
evaporator pipe temperature will be reached
at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
-4-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
On/Off
: Lights up during the system operation.
Sleep Mode
: Lights up during Sleep Mode Auto operation.
Timer
: Lights up during Timer operation.
Defrost Mode
: Lights up during Defrost Mode or
Hot Start operation.(Heat pump model only)
Outdoor unit operation : Lights up during outdoor unit operation.
(Cooling model only)
Temperature
: Indicate the setting temperature.
OUT
DOOR
Page of 55
Display

Click on the first or last page to see other LS-P1260BB service manuals if exist.