Functions
ƒU
Room temperature sensor. (THERMISTOR)
ƒU
Maintains the room temperature in accordance with the Setting Temp. 
ƒU
Indoor fan is delayed for 5 sec at the starting.
ƒU
Restarting is inhibited for approx. 3 minutes.
ƒU
High, Med, Low
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode (for Heating Model)
OUTDOOR --- Lights up in compressor operation (for Cooling Model)
ƒU
Intermittent operation of fan at low speed.
ƒU
The fan is switched to low(Cooling), med(Heating) speed.
ƒU
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
ƒU
The fan is switched to intermittent or irregular operation
ƒU
The fan speed is automatically switched from high to low speed. 
ƒU
The louver can be set at the desired position or swing 
up and down automatically. 
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
ƒU
Both the indoor and outdoor fan 
stops during deicing.
ƒU
The indoor fan stops until the 
evaporator piping temperature 
will be reached at 28
¡
.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
ƒ¡
3
ƒ¡
Deice (defrost) control (Heating)
Hot-start Control (Heating)
ƒ¡
4
ƒ¡
TEMPERATURE
TEMPERATURE
LOW
LOW
HIGH
HIGH
Remote Controller
Operation ON/OFF
(Cooling model only) (Heating model only)
Cooling Operation Mode (      )  
Soft Dry Operation Mode  (      )
(Low)
(Med)
(High)
(CHAOS)
: High: 39°C                   LOW : 11°C
Down to 18°C
Up to 30°C,
Cooling
: OFF, ON, OFF               ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Fuzzy Operation Mode (     )
Heating Operation Mode (     )
Operation Mode Selection
Fan Speed Selection
Room, Temperature Display
Temperature Setting
Setting the Time or timer
Timer Selection
Timer Setting
Timer Cancel
Sleep Operation
Airflow Direction Control
Fan Operation Mode
Reset
Down to 16°C
Up to 30°C,
Heating
Installation 
1)  Selection of the best location
1.  Indoor unit. 
• There should not be any heat source or steam near
the unit. 
• There should not be any obstacles to prevent the air
circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consid-
eration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
2.  Outdoor unit.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted.
• There should not be any animals or plants which
could affected by hot air discharged.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation.
Ringt
Rear right
Down right
Rear left
left
Front
Pipe size
Max. piping
Max.
GAS LIQUID
A(m)
B(m) 
3/8"
1/4"
10~15
5~7
1/2"
1/4"
10~15
5~7
More than 
         5cm
More than 5cm
More than eye-level
More than
5cm
More than
70cm
More than 
10cm
More than
10cm
A
B
Indoor unit
Outdoor unit
1. Installation of indoor, Outdoor unit 
ƒ¡
22
ƒ¡
LS-P0760CL/P0760HL
LS-P0820CL
LS-P0960CL/P0960HL
LS-P0962HL
LS-S0960CL/S0960HL
LS-S1120CL
LS-S1260CL/S1260HL
LS-S1420CL/S1421CL
length
elevation
ƒ¡
31
ƒ¡
5. Bend the tubing as shown in the figure and
bind the pipings, the connecting cables and the
drain hose altogether. 
• Make a small loop for easy connection later. 
6. Wrap the tubing, the drain hose and the con-
necting cable 
7. Indoor unit installation
• Hook the indoor unit onto the upper position of instal-
lation plate. (Engage the two hooks of the rear top of
the indoor unit with the upper edge of the installation
plate.)
Insure the hooks are properly seated on the installa-
tion plate by moving it in left and right.
CAUTION : Take care to arrange the pipings, drain
hose and cables as the feature 30 page for
inserting it into the indoor unit and mount
the  indoor unit on the installation plate.
Connecting cable
Drain hose
Press the lower left and right side of the unit
against the Installation Plate until the hooks
engages with their slots (sound click). 
Gas side piping
Liquid side piping
Drain hose
Connecting
cable
Loop
Tape
Page of 65
Display

LG LS-P0962HL Service Manual ▷ Download

  • DOWNLOAD LG LS-P0962HL Service Manual ↓ Size: 1.71 MB | Pages: 65 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-P0962HL in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-P0962HL Air Conditioner. Information contained in LG LS-P0962HL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.