2)  Connection of Pipings 
1. Remove the installation plate
• Pull the two '
¡
' marked portion of bottom of the chas-
sis and pull the installation plate out of chassis.
2. Route the drain hose and the indoor tubing.
3. Insert the pipings, the connecting cables and
the drain pipe throught the piping hole on the
wall. 
4. Connect the pipings and the indoor tubing, and
drain hose and drain pipe.                         
• Don't connect the cable to the indoor unit.
•  Wrap the insulation material around the connecting
portion.
•  Glue up the connection portion of drain hose and
drain pipe.
ƒ¡
30
ƒ¡
For right rear piping 
Pipe Size     
Torque      
Liquid Side (1/4")
1.8kg·m  
Gas Side (3/8")  
4.2kg·m 
Installation plate
pull
pull
Indoor unit tubing
Flare nut   Pipings
Torque wrench
Spanner
Plastic Bands
Insulation material
Drain Pipe
Drain Hose
Adhesive
Outdoor
Drain pipe
Connecting piping
Indoor
Connecting cable
,
,
(LS-P0760CL/P0760HL, LS-P0820CL, LS-P0960CL/P0960HL, LS-P0962HL)
Operation 
(1) Name and Function-Remote Control (Cooling Models)
Signal transmitter. 
Transmits the signals
to the room air conditioner.
ƒ¡
41
ƒ¡
Remote Controller 
RESET
ON
TIME
a.m.
p.m.
OFF
TIME
a.m.
p.m.
Hr.
ON
OFF
SET
CANCEL
1
 
2
9
10
3
4
5
6
7
8
12
13
11
⁄A
Operation display
Displays the operation conditions.
⁄B
Start/Stop Button
Operation starts when this button is pressed, and
stops when the button is pressed again.
⁄C
Operation Mode Selection Button
Used to select the operation mode.
• Cooling Operation Mode.
• Soft Dry Operation Mode.
• Auto Operation Mode.
⁄D
ON Timer Button
Used to set the time of starting operation.
⁄E
OFF Timer Button
Used to set the time of stopping operation.
⁄F
Time Setting Button
Used to adjust the time.
⁄G
Timer Set Button
Used to set the timer when the desired time is
obtained.
⁄H
Timer CANCEL Button
Used to cancel the timer operation.
⁄I
Sleep Mode Auto Button
Used to set Sleep Mode Auto Operation.
⁄J
Fan Operation Button
Used to circulate room air without cooling.
⁄K
Room Temperature Checking Button
Used to check the room temperature.
⁄L
Airflow Direction Control Button
Used to set the desired vertical airflow direction.
⁄M
Reset Button
(2) Name and Function-Remote Control  (Heat Pump Models)
Signal transmitter. 
Transmits the signals
to the room air conditioner.
ƒ¡
42
ƒ¡
Remote Controller 
RESET
ON
TIME
a.m.
p.m.
OFF
TIME
a.m.
p.m.
Hr.
ON
OFF
SET
CANCEL
1
 
2
9
10
3
4
5
6
7
8
12
13
11
⁄A
Operation display
Displays the operation conditions.
⁄B
Start/Stop Button
Operation starts when this button is pressed, and
stops when the button is pressed again.
⁄C
Operation Mode Selection Button
Used to select the operation mode.
• Cooling Operation Mode.
• Soft Dry Operation Mode.
• Auto Operation Mode.
• Heating Operation.
⁄D
ON Timer Button
Used to set the time of starting operation.
⁄E
OFF Timer Button
Used to set the time of stopping operation.
⁄F
Time Setting Button
Used to adjust the time.
⁄G
Timer Set Button
Used to set the timer when the desired time is
obtained.
⁄H
Timer CANCEL Button
Used to cancel the timer operation.
⁄I
Sleep Mode Auto Button
Used to set Sleep Mode Auto Operation.
⁄J
Fan Operation Button
Used to circulate room air without heating.
⁄K
Room Temperature Checking Button
Used to check the room temperature.
⁄L
Airflow Direction Control Button
Used to set the desired vertical airflow direction.
⁄M
Reset Button
Disassembly of the parts (Indoor unit)
Warning :
Disconnect the unit from power supply before making
any checks.
Be sure the power switch is set to “OFF”. 
To remove the Grille from the Chassis. 
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Open the screw caps upward and remove the
securing screws.
• To remove the Grille, pull the lower left and right
side of the grille toward you (Slightly tilted) and lift it
straight upward.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sensor
holder, Motor, Evaporator & P.C.B.
Up-and-down air direction louver
Screw
Screw cap
ƒ¡
43
ƒ¡
Page of 65