6. Indoor unit installation.
• Hook the indoor unit onto the upper portion of instal-
lation plate. (Engage the two hooks of the rear top
of the indoor unit with the upper edge of the installa-
tion plate.)
Ensure the hooks are properly seated on the instal-
lation plate by moving it in left and right.
7.  Connecting the pipings to the indoor unit    
• Align the center of the pipings and sufficiently tight-
en the flare nut with fingers. 
• Finally, tighten the flare nut with torque wrench until
the wrench clicks.
Wrench tightening the flare nut with forque wrench,
ensure the direction for tightening follows the arrows
on the wrench.
8. Wrap the insulation material around the con-
necting portion.
Connecting
cable
Drain hose
Press the lower left and right side of the unit
against the installation Plate until the hooks
engages with their slots(sound click).
Indoor unit tubing
Flare unt    Pipings
Torque wrench
Spanner
Pipe Size    
Torque      
Liquid Side(1/4")
1.8Kg
¡⁄
m  
Gas Side(1/2")   
5.5Kg
¡⁄
m    
25
Plastic Bands
Insulation material
Wrap the insulation material around the con-
necting portion.
3. Route the indoor tubing with the drain
hose to the piping hole as desired
position.
4. Insert the pipings and the connecting cable
into the piping hole.
5. Insert the connecting cable into the indoor unit.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
6. Tape the tubing, drain hose and the connecting
cable.
Outdoor
Piping
Indoor
Connecting cable
Indoor/outdoor
connecting cable
Taping
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
26
Tubing holder
Press
1
Pull
2
To remove the holder,
press the bottom of the
chassis near the holder
upwards and pull the tab
out of its hole.
For the left pipings 
7. Indoor unit installation.
• Hook the indoor unit onto the upper portion of instal-
lation plate. (Engage the two hooks of the rear top
of the indoor unit with the upper edge of the installa-
tion plate.)
Ensure the hooks are properly seated on the instal-
lation plate by moving it in left and right.
8.  Connecting the pipings to the indoor unit    
• Align the center of the pipings and sufficiently tight-
en the flare nut with fingers. 
• Finally, tighten the flare nut with torque wrench until
the wrench clicks.
Wrench tightening the flare nut with forque wrench,
ensure the direction for tightening follows the arrows
on the wrench.
9. Wrap the insulation material around the con-
necting portion.
Plastic Bands
Insulation material
Wrap the insulation material around the con-
necting portion.
27
Connecting
cable
Drain hose
Press the lower left and right side of the unit
against the installation Plate until the hooks
engages with their slots(sound click).
Indoor unit tubing
Flare unt    Pipings
Torque wrench
Spanner
Pipe Size    
Torque      
Liquid Side(1/4")
1.8Kg
¡⁄
m  
Gas Side(1/2")   
5.5Kg
¡⁄
m    
Gas Side(5/8")
6.5Kg
¡⁄
m  
10.Set the pipings and the connecting cable to the
back of the chassis with the tubing holder.
11. Indoor unit installation.
• Hook the indoor unit onto the upper portion of instal-
lation plate. (Engage the two hooks of the rear top
of the indoor unit with the upper edge of the installa-
tion plate.)
Ensure the hooks are properly seated on the instal-
lation plate by moving it in left and right.
Tubing holder
Taping
Piping
Drain hose
Hook
1
Push
2
Connecting
cable
Drain hose
Press the lower left and right side of the unit
against the installation Plate until the hooks
engages with their slots(sound click).