DOWNLOAD LG LS-P0960HL Service Manual ↓ Size: 1.55 MB | Pages: 69 in PDF or view online for FREE

Model
LS-P0960HL
Pages
69
Size
1.55 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-p0960hl.zip
Date

LG LS-P0960HL Service Manual ▷ View online

1) Connection of power supply 
1. Connect the power supply cord to independent
power supply. 
2. Prepare the remote control.
•  Insert two batteries provided.
Remove the cover from the back of the remote con-
trol.
• Slide the cover according to the arrow directon. 
• Insert the two batteries.
(Two "R03" or "AAA" dry-cell batteries or equiva-
lent).
•  Be sure that the (+) and (-) directions are correct.
• Be sure that both batteries are new.
Re-attach the cover.
• Slide it back into position.
3. Operate the unit at cooling operation mode for
fitteen minutes or more.
• Anchor the outdoor unit with a bolt and nut (ø10cm)
tightly and horizontally on a concrete or rigid mount.
• When installing on the wall, roof or rooftop, anchor
the mounting base securely with a nail or wire
assuming the influence of wind and earthquake.
• In the case when the vibration of the unit is con-
veyed to the house, settle the unit with an anti-
vibration rubber.
2) Evaluation of the performance
1. Measure the temperature of the intake and dis-
charge air.
2. Ensure the difference between the intake tem-
perature and the discharge one is more than
8°C.
Tubing connection 
discharge air
Settlement of Outdoor Unit
6. Test running 
39 
2)  Indoor unit installation 
The mounting wall should be strong and solid enough
to prevent it from the vibration.
1. Mount the installation plate on the wall with
four Type "A" screws.
•  Always mount the installation plate horizontally by
aligning the marking-off line with using the thread
and a level.
LS-P0760CL/P0760HL
LS-P0960CL/P0960HL
•  To remove the installation plate, pull the two '
¡
'
marked portion of bottom of chassis and pull the
installation plate out of chassis.
2.  Drill the piping hole with 70mm dia. Hole-core
drill. 
•  Line according to the arrows marked on lower the
left and the right side of the installation plate.
The meeting point of the extended line is the center
of the hole.
• Drill the piping hole at either the right or the left and
the hole should be slightly slant to the outdoor side.
Installation Plate
Thread
Marking-off line
Weight
Type “A” screw
Left rear piping
ø70mm
ø70mm
50mm
20mm
20mm
80mm
LS-P0760CL/P0760HL
LS-P0960CL/P0960HL
Right rear piping
WALL
5~7mm
Indoor
Outdoor
LS-S0960CL/S0960HL
LS-S1260CL/S1260HL
Left rear piping
Right rear piping
Center
Center
ø70mm
ø70mm
The lower left and right side of installa-
tion Plate
22
££……
££
æ
1)  Preparation of pipings 
1. Cut the pipes and the cable.                       
• Use the accessory piping kit or the pipes purchased
locally. 
• Measure the distance between the indoor and the
outdoor unit.
• Cut the pipes a little longer than measured distance.
• Cut the cable 1.5m longer than the length of pipe.       
2.  Remove burrs. 
• Remove burrs from cut edges of pipes.
• Turn the pipe end toward down to avoid the metal
powder entering the pipe.
Caution:
If burrs are not removed, they may cause a gas leak-
age.                                                               
3. Flaring the pipes.                                   
• Insert the flare nuts, mounted on the connection
ports of both indoor and outdoor unit, onto the cop-
per pipes. Some refrigerant gas may leak, when the
flare nuts are removed from the indoor unit, as
some gas is charged to prevent the inside of the
pipe from rusting.
• Fit the copper pipe end into the Bar of flare tool
about 0.5~1.0mm higher. (See illustration).
• Flare the pipe ends.
4. Tape the flaring portion to protect it from the
dust or damages.
90
Pipe cutter
Slanted   Rough
Point down
Reamer
Pipe
Red arrow mark
"A";
§j
12.7mm(
3
/
8
")
¡
0.5mm
"A";
§j
9.52mm(
1
/
2
")
¡
1.0mm
"A";
§j
6.35mm(
1
/
4
")
¡
1.0mm
Copper
pipe
"A"
Clamp 
handle
Cone
Yoke
Handle
Bar 
When properly flared, the internal surface flare
will evenly shine and be of even thickness. Since
the flare part comes into contact with the con-
nectors, carefully check the flare finish.
= Improper flaring =
Inclined 
Surface
damaged
Cracked
Uneven
thickness
2. Piping and Drainage of indoor unit 
23
2)  Connection of pipings 
1.  Remove the indoor tubing with Drain hose to
the hole. 
•  Remove tubing holder and pull the tubing out of the
chassis.
2. Refix the tubing holder into original position.
3. Route the tubing and the drain hose straight
backwards(see figure).
4. Insert the connecting cable into the indoor unit
through the piping hole.
Tubing holder
Press
1
Pull
2
To remove the holder,
press the bottom of the
chassis near the holder
upwards and pull the tab
out of its hole.
For right rear piping
24
Outdoor
Piping
Indoor
Connecting cable
Indoor/outdoor
connecting cable
Taping
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
5. Tape the tubing, drain hose and the connecting
cable.
(LS-S0960CL/S0960HL, LS-S1260CL/S1260HL)
Page of 69
Display

Click on the first or last page to see other LS-P0960HL service manuals if exist.