DOWNLOAD LG LS-K1860HL / LS-2460HL Service Manual ↓ Size: 7.53 MB | Pages: 112 in PDF or view online for FREE

Model
LS-K1860HL LS-2460HL
Pages
112
Size
7.53 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-k1860hl-ls-2460hl.zip
Date

LG LS-K1860HL / LS-2460HL Service Manual ▷ View online

- 8 -
3828A30008F
LS-K1820HL/HN (Indoor)
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
1H00843A
4930AR3309A
3H02789E
3141A20002B
4681A20003B
5901AR2441E
3H02821A
5421A20021
5421A20011C
4995A20021C
4994AR0052A
6871AQ2420P
6871A20035
3H01487F
6323AQ2333A
3H02255W
3H03462
6871A30009B
2Q01026C
3531A10008C
5008AR1629A
5990A30001A
5990A30002A
4681AR2727H
4681A2727
5251AR2575A
3531A10007C
3530AR1628A
3550AR3592C
5231AR2595B
5230A20001A
3531A20011C
6711A20003A
733010
149303
135501
131410
346811
359011
342800
354212
249951
249940
268714
WOCZZ
263230
264110
268712
266090
135311
135301
159901
159901-1
146811
146811-1
352150
135312
135500
152312
152302
135313
W6711
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
PLATE ASS'Y, INSTALL
HOLDER, TUBING
COVER, TUBING
CHASSIS ASS'Y
MOTOR ASS'Y, AC
FAN ASS'Y, CROSS FLOW
BEARING
EVAPORATOR ASS'Y, FINAL
CONTROL BOX ASS'Y, INDOOR
CONTROL BOX, (IN)
PWB(PCB) ASS'Y, MAIN
CAPACITOR
THERMISTOR ASS'Y
POWER CORD ASS'Y
PWB(PCB) ASS'Y, DISPLAY
H.V ASS'Y
GRILLE ASS'Y, DISCHARGE(IN)
GRILLE DISCHARGE
VANE HORIZONTAL
VANE HORIZONTAL
MOTOR ASS'Y, STEP
MOTOR ASS'Y, STEP
HOSE ASS'Y, DRAIN
GRILLE ASS'Y, FRONT
GRILLE FRONT
COVER CONTROL(IN)
FILTER ASS'Y, A/C
FILTER, (MECH) AIR
GRILLE ASS'Y, INLET SUB
REMOCON CONTROLLER ASS'Y
- 9 -
3828A30008F
LS-K1860HL/HN (Indoor)
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
1H00843A
4930AR3309A
3H02789E
3141A20002B
4681A20003D
5901AR2441E
3H02821A
5421A20021
5421A20011B
4995A20021A
4994AR0052A
6871AQ2420M
6871A20035
3H01487G
6323AQ2333A
3H02255W
3H03462
6871A30009B
2Q01026C
3531A10008C
5008AR1629A
5990A30001A
5990A30002A
4681AR2727H
4681A2727
5251AR2575A
3531A10007C
3530AR1628A
3550AR3592C
5231AR2595B
5230A20001A
3531A20011C
6711A20003A
733010
149303
135501
131410
346811
359011
342800
354212
249951
249940
268714
WOCZZ
263230
264110
268712
266090
135311
135301
159901
159901-1
146811
146811-1
352150
135312
135500
152312
152302
135313
W6711
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
PLATE ASS'Y, INSTALL
HOLDER, TUBING
COVER, TUBING
CHASSIS ASS'Y
MOTOR ASS'Y, AC
FAN ASS'Y, CROSS FLOW
BEARING
EVAPORATOR ASS'Y, FINAL
CONTROL BOX ASS'Y, INDOOR
CONTROL BOX, (IN)
PWB(PCB) ASS'Y, MAIN
CAPACITOR
THERMISTOR ASS'Y
POWER CORD ASS'Y
PWB(PCB) ASS'Y, DISPLAY
H.V ASS'Y
GRILLE ASS'Y, DISCHARGE(IN)
GRILLE DISCHARGE
VANE HORIZONTAL
VANE HORIZONTAL
MOTOR ASS'Y, STEP
MOTOR ASS'Y, STEP
HOSE ASS'Y, DRAIN
GRILLE ASS'Y, FRONT
GRILLE FRONT
COVER CONTROL(IN)
FILTER ASS'Y, A/C
FILTER, (MECH) AIR
GRILLE ASS'Y, INLET SUB
REMOCON CONTROLLER ASS'Y
- 3 -
Functions
Room temperature sensor. (THERMISTOR)
Maintains the room temperature in accordance with the Setting Temp.
Indoor fan is delayed for 5 sec at the starting.
Restarting is inhibited for approx. 3 minutes.
High, Med, Low
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode (for Heating Model)
OUTDOOR --- Lights up in compressor operation (for Cooling Model)
Intermittent operation of fan at low speed.
The fan is switched to low(Cooling), med(Heating) speed.
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
The fan is switched to intermittent or irregular operation
The fan speed is automatically switched from high to low speed.
The louver can be set at the desired position or swing
up and down automatically.
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
Both the indoor and outdoor fan
stops during deicing.
The indoor fan stops until the
evaporator piping temperature will
be reached at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
Deice (defrost) control (Heating)
Hot-start Control (Heating)
- 4 -
TEMPERATURE
TEMPERATURE
LOW
LOW
HIGH
HIGH
Remote Controller
Operation ON/OFF
(Heating model only)
Cooling Operation Mode. (
)
Healthy Dehumidification
Operation Mode. (
)
(Low)
(Med)
(High)
(CHAOS)
: (High: 39°C
LOW : 11°C)
Down to 18°C
Up to 30°C
Cooling
: OFF, ON, OFF
ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Auto Operation Mode. (
)
Heating Operation Mode. (
)
Operation Mode Selection
Fan Speed Selection
Room, Temperature Display
Temperature Setting
Setting the Time or timer
JET COOL
Timer Selection
Timer Setting
Timer Cancel
Sleep Operation
Airflow Direction Control
Fan Operation Mode
Reset
Down to 16°C
Up to 30°C
Heating
Page of 112
Display