- 38 -
Operation
(1) Name and Function-Remote Control (Cooling Models)
Signal transmitter.
Transmits the signals
to the room air conditioner.
Remote Controller
1
2
8
9
10
11
3
4
5
6
7
12
13
OPERATION DISPLAY
Displays the operation conditions.
START/STOP BUTTON
Operation starts when this button is pressed and stops when
the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained and
to cancel the Timer operation.
CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired
up/down airflow direction.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heat-
ing (turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUT-
TON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
NEGATIVE ION (Not on all models)
Used to generate negative ion.
HORIZONTAL AIRFLOW DIRECTION
CONTROL BUTTON
(Not on all models)
Used to set the desired horizontal airflow direction.
1
2
3
4
5
6
7
8
9
10
11
12
13
- 39 -
(2) Name and Function-Remote Control (Heat Pump Models)
Signal transmitter.
Transmits the signals
to the room air conditioner.
Remote Controller
1
2
8
9
10
11
3
4
5
6
7
12
13
OPERATION DISPLAY
Displays the operation conditions.
START/STOP BUTTON
Operation starts when this button is pressed and stops when
the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained and
to cancel the Timer operation.
CHAOS SWING BUTTON
Used to stop or start louver movement and set the desired
up/down airflow direction.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heat-
ing (turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUT-
TON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
NEGATIVE ION (Not on all models)
Used to generate negative ion.
HORIZONTAL AIRFLOW DIRECTION
CONTROL BUTTON
(Not on all models)
Used to set the desired horizontal airflow direction.
1
2
3
4
5
6
7
8
9
10
11
12
13
- 1 -
3828A30008F
Exploded View & Replacement Parts List
1. Indoor Unit
    18K models
- 10 -
3828A30008F
LS-K1861HL/HN (Indoor)
LOCATION NO.
No.
DESCRIPTION
PART No.
Q'TY
REMARKS
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
1H00843A
4930AR3309A
3H02789E
3141A20002A
4681A20003D
5901AR2441E
3H02821A
5421A20021
5421A20011B
4995A20021M
4994AR0052A
6871AQ2420
6871A20035B
3H01487G
6323AQ2333A
3H02255W
3H03462
6871A30009B
2Q01026C
3531A10008B
5008AR1629A
5990A30001A
5990A30002A
4681AR2727H
4681A2727K
5251AR2575A
3531A10007C
3530AR1628A
3550AR3592C
5231AR2595B
5230A20001A
3531A20011C
6711A20003D
733010
149303
135501
131410
346811
359011
342800
354212
249951
249940
268714
WOCZZ
263230
264110
268712
266090
135311
135301
159901
159901-1
146811
146811-1
352150
135312
135500
152312
152302
135313
W6711
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
PLATE ASS'Y, INSTALL
HOLDER, TUBING
COVER, TUBING
CHASSIS ASS'Y
MOTOR ASS'Y, AC
FAN ASS'Y, CROSS FLOW
BEARING
EVAPORATOR ASS'Y, FINAL
CONTROL BOX ASS'Y, INDOOR
CONTROL BOX, (IN)
PWB(PCB) ASS'Y, MAIN
CAPACITOR
THERMISTOR ASS'Y
POWER CORD ASS'Y
PWB(PCB) ASS'Y, DISPLAY
H.V ASS'Y
GRILLE ASS'Y, DISCHARGE(IN)
GRILLE DISCHARGE
VANE HORIZONTAL
VANE HORIZONTAL
MOTOR ASS'Y, STEP
MOTOR ASS'Y, STEP
HOSE ASS'Y, DRAIN
GRILLE ASS'Y, FRONT
GRILLE FRONT
COVER CONTROL(IN)
FILTER ASS'Y, A/C
FILTER, (MECH) AIR
GRILLE ASS'Y, INLET SUB
REMOCON CONTROLLER ASS'Y
Page of 112
Display

LG LS-K1860HL / LS-2460HL Service Manual ▷ Download

  • DOWNLOAD LG LS-K1860HL / LS-2460HL Service Manual ↓ Size: 7.53 MB | Pages: 112 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-K1860HL / LS-2460HL in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-K1860HL / LS-2460HL Air Conditioner. Information contained in LG LS-K1860HL / LS-2460HL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.