-17-
7. Fuzzy mode operation
• When any of operation mode is not selected like the moment of the power on or when the unit turned off, the
operation mode is selected.
• When determining the operation mode, the compressor, outdoor fan are off and only the indoor fan is operat-
ed for 15seconds, then an operation mode is selected according to.
Basis of determining operating mode
Outdoor temp.
over 24°C
21~24°C
18~21°C
below 18°C
Operating Mode
Cooling
Healthy Dehumidification
intake air temp. 
25°C …Dehumidification
intake air temp. < 25°C … Heating
Heating
7.1 Fuzzy operation for cooling
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like cooling mode operation.
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• When the Fuzzy key(=setting temp. key) is input after the initial setting temperature is selected, the  Fuzzy
key value and intake air temperature at that time are compared to select the setting temperature automatical-
ly according to the fuzzy rule.
• While in Fuzzy operation, the air flow speed of the indoor fan is automatically operated by chaos logic.
at beginning
during opertion
Intake air temp.
over 26°C
18~26°C
below 18°C
18~30°C
below 18°C
over 30°C
Setting temp.
25°C
intake air temp. -05°C 
18°C
Fuzzy rule
18°C Fuzzy rule
30°C Fuzzy rule
Fan speed
CHAOS airflow
-18-
7.2 Fuzzy operation for Heating
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like heating mode operation.
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• When the Fuzzy key(=setting temp. key) is input after the initial setting temperature is selected, the Fuzzy
key value and intake air temperature at that time are compared to select the setting temperature automatical-
ly according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically operated by CHAOS logic.
at beginning
during opertion
Outdoor temp.
over 26°C
0~5°C
-5~0°C
below -5°C
16~30°C
below 16°C
over 30°C
Setting temp.
intake air temp. +0.5°C
intake air temp. +1.0°C
intake air temp. +1.5°C
intake air temp. +2.0°C
Fuzzy rule
18°C Fuzzy rule
30°C Fuzzy rule
Fan speed
CHAOS airflow
7.3 Fuzzy operation for dehumidification
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like dehumidefication mode operation.
at beginning
during operation
Outdoor temp.
over 26°C
18~26°C
below 18°C
Setting temp.
25°C
intake air temp. -0.5°C
18°C
same as dehumidification mode
Fan speed
CHAOS airflow
-19-
8. Jet cool mode operation
• While  in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the
other mode operation(cooling, dehumidification, ventilation), the Jet Cool mode is operated.
• In the Jet Cool mode, the indoor fan is operated super-high speed for 30 min. at cooling mode operation.
• In the Jet Cool mode, the room temperature is controlled to the setting temperature, 18°C.
• When the sleep timer mode input while the Jet Cool mode operation, the Jet Cool mode has the priority.
• When the Jet Cool key is input, the upper/lower vane is reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.
9. Swing mode
9.1 Chaos swing mode of not fuzzy mode operation
• By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is
fixed to the desired direction.
Chaos swing of LS-J0760NL/LS-J0901NL/NT
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of cooling
Mode 8
< Cooling Mode >
8
°
135
°
< Heating Mode >
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of heating
Mode 8
8
°
135
°
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of cooling
Mode 8
< Cooling Mode >
7
°
125
°
< Heating Mode >
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of heating
Mode 8
7
°
125
°
Chaos swing of SL-L1260NL/NT
Installation
1. Installation of indoor, Outdoor unit 
-26-
More than 5cm
More than 5cm
More than 2.3m
More than 5cm
More than 10cm
More than 10cm
More 
than 60cm
More than 60cm
More than 70cm
1) Select the best location 
1. Indoor unit
§
Do not have any heat or steam near the unit.
§
Select a place where there are no obstacles in
front of the unit.
§
Make sure that condensation drainage can be
conveniently routed away.
§
Do not install near a doorway.
§
Ensure that the space around the left and right of
the unit is more than 5cm. The unit should be
installed as high on the wall as possible, allowing
a minimum of 5cm from ceiling.
§
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
2. Outdoor unit
§
If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat
radiation from the condenser is not restricted.
§
Ensure that the space around the back and sides
is more than 10cm. The front of the unit should
have more than 70cm of space.
§
Do not place animals and plants in the path of the
warm air.
§
Take the air conditioner weight into account and
select a place where noise and vibration are mini-
mum.
§
Select a place so that the warm air and noise
from the air conditioner do not disturb neighbors.
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.
CAUTION
2) Piping length and elevation
7K
3/8" 1/4"
5
7
15
20
9K, 12K
1/2" 1/4"
5
7
15
20
Pipe Size
Capacity
(Btu/h)
GAS LIQUID
Max. 
length
(m)
Additional
Refrigerant
(g/m)
Max.
Elevation
B
(m)
Standard
Length
(m)
* Both gas and liquid interconnecting pipes must be
insulated as a pair, but it is not necessary to individu-
ally insulate them.
Outdoor unit
Indoor unit
A
B
A
Oil trap
Outdoor unit
Indoor unit
B
In case more than 5m
• Capacity is based on standard length and maximum
allowance length is on the basis of reliability.
• Oil trap should be installed every 5~7 meters.
CAUTION
Page of 73