Functions
• Room temperature sensor. (Thermistor)
• Pipe temperature sensor. (Thermistor)
• Maintain the room temperature in accordance with the Setting Temp. 
• Indoor fan is delayed for 5 sec at the starting.
• Restarting is for approx. 2 minutes.
• Super High, High, Med, Low
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Defrost Mode (for Heating Model)
• Intermittent operation of fan at low speed.
• The fan is switched to low(Cooling), low(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed. 
• The louver can be set at the desired position or swing 
up and down automatically. 
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting the Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Operation indication Lamps (LED)
Soft Dry Operation Mode
ƒU
Both the indoor and outdoor fan
stops during defrosting.
ƒU
The indoor fan stops until the 
evaporator pipe temperature will be
reached at 28°C.
Sleep Mode Auto Control
Natural Air Control by CHAOS Logic
Airflow Direction Control
-3-
Defrost(Deice) control (Heating)
Hot-start Control (Heating)
-4-
• If power is on, it will operate to chage capacitor (330µF/450WV) on controller and power relay will oper-
ate after about 2~5sec.
• If outdoor temp. is below 0°C, sump heater is operating for 20min.
• At the initial, It will be operated compressor after 1min. for preheating.
• The active power filter is designed to correct power factor(cos 
θ
) and to regulate DC link voltage.
• It will be operated PFC circuit when the compressor freq. is over 12Hz.
• If DC link voltage is not over DC 350V in 6 sec. in case of PFC on, it does not operating of compressor.
• The final operating freq. of comp. is set the lowest freq. that limited outdoor temp., discharge pipe temp.,
heat-sink temp., target freq., owing to CT.
• It will be changed the drive voltage of comp. according to operating frequency.
• It is only operated in the heating operation mode except defrosting operation.
• High speed
-Although fan motor speed is low, it will change high speed in case of below AC193V, over 45°C of out-
door temp., and over fc, fh of comp. Freq.
• Low speed
- Nomal mode and over AC270V
Outdoor Unit
Power relay control
Stand by control at low temp.
Active power filter control(PFC)
Comp. Freq. control
Overheatng. Protection(Powr module)
Freq. speed control(up/down speed)
V/F control
Total current control (over current protechton)
DC peak current control
4 way valve control
Outdoor fan motor control
Discharge pipe temp. control
-5-
Healthy Dehumidification Operation Mode.(       )
Remote Controller
Operation ON/OFF
Reset
Operation Mode Selection
Temperature Setting
Timer Selection
Timer Setting
JET COOL
Timer Cancel
Sleep Operation
Airflow Direction Control
(Heating 
model only)
TEMPERATURE
LOW
HIGH
Cooling Operation Mode.(       )
Heating Operation Mode.(       )
Auto Operation Mode.(       )
Fan Operation Mode
Room, Temperature Display
Setting the Time or Timer
ON
OFF
SET
CANCEL
Fan Speed Selection
(Low)
(Med)
(High)
(CHAOS)
: (High: 39°C                   LOW : 11°C)
Down to 18°C
Up to 30°C
Cooling
: OFF, ON, OFF               ON
: Cancel Sleep Mode, Timer ON or Timer OFF
: 1, 2, 3, 4, 5, 6, 7, Off Timer
: Fan Operates without cooling or heating.
Down to 16°C
Up to 30°C
Heating
2-way, 3-way Valve 
2-way Valve (Liquid Side)
3-way Valve (Gas Side)
Shaft position
Shaft position
Service port 
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap) 
Open
Closed
Open
(counter-clockwise)
(clockwise)
(push-pin or with
vacumm pump)
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Closed
Open
Open
(clockwise)
(counter-clockwise)
(connected manifold
gauge) 
Open
Open
Open
(with charging 
cylinder)
Open
Open
Open
(with charging
cylinder) 
Open
Open
Open
Open
Works
Shipping
Air purging
(Installation)
Operation
Pumping down
(Transfering)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing) 
1.
2.
3.
4.
5.
6.
Valve cap
Open position
Closed position
Pin
Service
port
Service
port cap
To outdoor unit
Flare nut
To 
piping 
connection
To outdoor unit
Hexagonal wrench (4mm)
Open position
Closed position
To 
piping 
connection
Flare nut
-44-
Open
(with charging cylinder)
Open
(with charging cylinder)
Page of 73
Display

LG LS-J0961NL Service Manual ▷ Download

  • DOWNLOAD LG LS-J0961NL Service Manual ↓ Size: 1.96 MB | Pages: 73 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG LS-J0961NL in PDF for free, which will help you to disassemble, recover, fix and repair LG LS-J0961NL Air Conditioner. Information contained in LG LS-J0961NL Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.