How to operate the power display (LS-_YL/UL Series)
• It must be displayed the power level that will be operating frequency of compressor.
• It indicates power levels that compressor operating frequency is controlled to depend on indoor and outdoor
conditions.
• It is displayed as below.
Heat mode operation
- Power level 1: below Step 2 of COMP. operating frequency
- Power level 2: below Step 4 of COMP. operating frequency
- Power level 3: Equal Step 5 of COMP. operating frequency
- Power level 4: below Step 7 of COMP. operating frequency
Operation mode except heat mode operation
- Power level 1: below Step 2 of COMP. operating frequency
- Power level 2: below Step 4 of COMP. operating frequency
- Power level 3: Equal Step 5 of COMP. operating frequency
- Power level 4: below Step 7 of COMP. operating frequency
-12-
Power Level 1
Power Level 2
Power Level 3
Power Level 4
-13-
2. Protection of the evaporator pipe from frosting
• If the indoor pipe temperaure is below 0°C in 7 min. after the compressor operates without pause while in
cooling cycle operation mode, 
➔ 
compressor, outdoor fan are turned off.
• When indoor pipe temp. is 7°C or higher after 2 min pause of compressor 
➔ 
compressor, outdoor fan is turned on according to the condition of the room temperature.
3. Protection of the indoor fan from droplet formation (Enclosure
sweat and condensed disposal test)
• Control condition : The system operates standard operation without this condition as follows.
Setting temperature <25°C
Indoor fan speed  
low speed
Outdoor temperature < 30°C
• Control method
In operation for 5~20 minutes in 
conditions, return to the previous COMP STEP after operation for
5~40 minutes at the COMP STEP 3. 
Comp. free
Comp. Step 4
Comp. Step 2
Comp. off
0˚C
3˚C
6˚C
7˚C
Indoor pipe
temp.
-14-
4. Cooling mode operation
• Operating frequency of compressor depend on the difference of the temperature.
(= intake air Temp.- Compressor off Temp.
• Compressor off temp.= setting temp. -0.5°C
on temp. = setting temp. +0.5°C
• If compressor operates at some operating frequency, the operating frequency of compressor cannot be
changed within 30 seconds.
• Condition of compressor turned off
- When intake air temperature stay at the temperature between setting temp. -0.5°C and setting temp. 
-1.0°C for 3 minutes continuously.
- When intake air temperature reaches below the temperature of setting temp. -1.0°C.
• Compressor 2 minutes delay
- The compressor can restart minimum 2 minutes later after compressor off.
Temp. differences
Comp. Operating frequency
over 3.0°C
Step 7
over 2.5°C
Step 6
2.0~2.49°C
Step 5
1.5~1.99°C
Step 4
1.0~1.49°C
Step 3
0.5~0.99°C
Step 2
0.0~0.49°C
Step 1
[The operating freq. step of comp.]
[The targeting operating freq. of comp. each model]
Model
7K Series(AC)
35
41
45
56
64
68
78
12K Series(AC)
30
40
45
55
61
67
72
9K Series(DC)
15
22
32
40
51
54
58
12K Series(DC)
15
28
40
53
66
71
76
Comp. Operating frequency
Step 1
Step 2
Step 3
Step 4
Step 5(Fr)
Step 6
Step 7
-15-
5. Healthy Dehumidification mode operation
• When the dehumidification operation is set by the remote controller the intake air temperature is detected and
the setting temp. is automatically set according to the intake air temperature.
• When intake air temp reaches above the temp of setting +1.0°C, condition of compressor same as cooling
mode operation.
• When intake air temperature reaches bolow the temp of setting –1.0°C, compressor operate step1~step3 and
indoor fan speed repeatly operate low or stop.
Intake air Temp.
32°C 
intake air temp.
26°C 
intake air temp. < 32°C
24°C 
intake air temp.< 26°C
18°C < intake air temp. < 24°C
intake air temp. 
18°C
Setting Temp.
25°C
25°C
intake air temp. -1°C
intake air temp. -0.5°C
18°C