6. Natural Wind by CHAOS logic
There are common rules in the irregular changes amid the breeze of highlands and valleys, the sound of
streams, the songs of birds in the forest and brain waves of relaxation.
Mmm... the breath-taking and touchy feeling of wind from the deep mountains and dark valleys.
Through analysis in its chaos simulator, Goldstar has successfully created such a feeling of freshness and
serenity by analyzing the frequency of natural wind.
Generally natural wind has the following character (frequency-Magnitude), for example dark vally, sea, mountain
wind.
So as to make a similar Natural wind function, Indoor fan speed is shifted to high from low or reversely according
to the CHAOS logic.
ƒ¡
21
ƒ¡
Magnitude
frequency(Hz)
natural wind function
7. Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as
following.
ƒ¡
22
ƒ¡
Intake Air temp.                   
Setting temp.+3
¡
(Compressor OFF)
Setting temp.
(Compressor ON)
INDOOR FAN
Low
OFF         Low
Low
OFF
COMPRESSOR
ON
OFF
ON
OFF
ƒU
A point; While the indoor Heat-Exchanger temperature is higher than 35°C fan operates at low speed, when 
it becomes lower than 35°C fan stops.
ƒU
B point; When the indoor Heat-Exchanger temperature is higher than 28°C, fan operates at seleted fan 
speed.
Selecting fan
speed
Selecting fan
speed
minimum
10sec.
maximum
4minutes
A
A
minimum
1min.
minimum
10sec.
B
8. Hot-Start Control
ƒU
The indoor fan stops until the evaporator piping temperature will be reached to 28
¡
.
ƒU
During heating operation, if piping temperatures falls below 26°C fan stops.
(But, in case of LS-D2460HL/2660HL, it stops below 25°C)
ƒU
The operation diagram is as following.
9. Deice Control
ƒU
Deicing operation is controlled by  timer and sensing the outdoor piping temperature.
ƒU
The first deicing starts only when the outdoor pipe temperature falls below -6
¡
after 60 minutes passed from
starting of heating operation and more than 10 minute operation of compressor.
ƒU
Deicing ends after 12 minutes passed from starting of deice operation or when the outdoor pipe temperature
rises over 12
¡
even if before 12 minutes.
ƒU
The second deicing starts only when the outdoor pipe temperture falls below -6
¡
after 60 minutes passed from
ending of the first deicing and more than 10 minute operation of compressor.
ƒ¡
23
ƒ¡
PIPING
TEMPERATURE
1min
COMPRESSOR
INDOOR FAN
ON
26°C
: Selected Fan
: Low Fan
: Fan Stop
28°C
More than 60 minutes 
of heating operation
Within 
12minutes
Deicing
Deicing
ON
OFF
ON
ON
ON
ON
OFF
OFF
COMPRESSOR
4-WAY VALVE
INDOOR FAN
-6°C
DEICE ON
12°C
DEICE OFF
The outdoor
piping Temp.
ON
More than 10 min. 
running of compressor
More than 10 min. 
running of compressor
More than 60 minutes 
of heating operation
30SEC
HOT-
START
ON
OFF
ON
10. Soft Dry Operation.
•  During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1
¡
, the compres-
sor OFF temperature is the setting temperature minus 0.5
¡
•  When the room temperature rises over the compressor ON temperature, the operation mode is switched to the
cooling mode.
•  When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
In this temperature range, 10min. Dry Operation, 5.5min operation OFF, 1.5min. only fan operation repeat. Dur-
ing 10min Dry operation, even if the room temperature falls below compressor OFF temperature, 10min(MAX)
Compressor ON from starting of Dry operation which includes 4 min(MAX). Compressor ON operation below
the comperssor OFF temperature.
•  In micom dehumidify mode, control of fan speed is as following. 
ƒ¡
24
ƒ¡
ROOM TEMP.
SETTING TEMP.+1°C
(COMP. ON)
SETTING TEMP.-0.5°C
(COMP. OFF)
INDOOR FAN 
OFF   LOW
OFF
OFF   LOW
COMPRESSOR 
ON
OFF
ON
OFF
ON
OFF
ON 
Selecting
Selecting
fan speed
LOW
fan speed
LOW
5.5 minutes
5.5 minutes
maximum 
4 minutes
1.5 minutes
1.5 minutes
10 minutes
maximum 
10minutes
3 minutes
Operation
Cooling
Cooling
operation
3minutes
Delay
Dry  operation
Page of 71
Display