(2) Outdoor Unit
1. LS-D2820CL, LS-D3020CL
2. LS-D2820HL, LS-D3020HL
ƒ¡
14
ƒ¡
OR(BR)     OR(BR)      OR(BR)   OR(BR)    OR(BR)  OR(BR)
(2) Outdoor Unit
3. LS-D2420CL, LS-D2620CL, LS-D1860(1)CL
4.  LS-D2460CL, LS-D2660CL, LS-D2461CL, LS-D2661CL
ƒ¡
15
ƒ¡
5. LS-D1860(1)HL/2420HL/2620HL/2460HL/2660HL/2461HL/2661HL
ƒ¡
16
ƒ¡
Operation Details
(1) The function of main control
1. Time Delay Safety Control
ƒU
3min
¡ƒ
The compressor is ceased for 3minutes to balance the pressure in the refrigeration cycle.
(Protection  of compressor)
ƒU
5sec
¡ƒ
Vertical air flow direction control louvers open in 5 seconds to prevent noise between louvers and wind.
ƒU
30sec
¡ƒ
The 4-way valve is ceased for 30sec. to prevent the refrigerant-gas abnormal noise when the Heating 
operation is OFF or switched to the other operation mode while compress is off.
While compressor is running, it takes 3~5 seconds to switch.
2. Airflow Direction Control
ƒU
This function is to swing the louver up and down automatically and to set it at the desired position. 
ƒU
The procedure is as the following. 
1st   ; Press the ON/OFF Button to operate the product.
2nd  ; Press the Airflow Direction Control Button to swing the louver up and down automatically. 
3nd  ; Repress the Airflow Direction Control Button to set the louver as the desired position. 
3. Cooling Mode Operation
ƒU
When selecting the Cooling(    ) Mode Operation, the unit will operate according to the setting by the remote
controller and the operation diagram is as following
4. Cooling or Heating Mode with Sleep Mode Auto Operation
ƒU
When selecting the Cooling(     ) or the Heating( 
) combined with the Sleep Mode Auto Operation(
), the
operation diagram is as following.
Horizontal
0
1
2
3
4
5
6
7
8
Setting point: 
Setting range for:
(Close)
110°
Cooling
Approx. 28°
Heating
Approx. 28°
Cooling
Heating
Heating
Cooling
Vertical airflow direction
Intake Air temp.
COMP. ON
(SET TEMP.+0.5
¡
COMP. OFF
(SET TEMP. -0.5
¡
)
More than
More than
3 minutes
3 minutes
Selecting
Selecting
Selecting
fan speed
fan speed
fan speed
COMPRESSOR
ON
OFF
ON 
OFF
ON
INDOOR FAN                                              
Low                                                   Low 