– 78 –
8) No heater operation works
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Is the heating operating?
Is the Compressor 
operating?
Is the Heat S/W of Main
PCB "ON"?
Heat S/W "ON"
Heater S/W "ON"
Replacement IC1 (MICOM)
Replacement IC3
Replacement RY6
Is the heater S/W of Main
PCB"ON"?
Is the DC 5V at 58 pin of IC1
(MICOM) 
Is the DC 12V at eack terminal?
(RY6 COIL)
Is the
AC220V (AC 240 V) between
connector(HEATER) and CN-outunit 
¥L
of
Main P.C.B
Check the heater wiring
Select the heating operation mode.
Compressor "ON"
– 64 –
Failures to Start
Check of circuit breaker
and fuse.
Check control switch.
Fan only fails to start
Improper wiring
Defect of fan motor
capacitor.
Irregular motor 
resistance 
 )
Irregular motor 
insulation 
 )
Replacement of fan motor.
Improper electric heater
Replacement of electric 
heater
Regular but fails to start.
Replacement of compressor
Electric heater is not energized
Loose terminal connection.
Improper wiring
Irregular motor resistance 
 )
Irregular motor insulation 
 )
Replacement of compressor
Drop of power voltage
Capacitor check
Replacement
Compressor only fails to
 start
Defect of compressor
capacitor
Check power source.
Check control switch
setting.
– 65 –
PACKAGE AIR CONDITIONER VOLTAGE LIMITS
9.1 No cooling and heating operation performed
1) Both the blower and the compressor do not work
NAME PLATE RATING
MINIMUM
MAXIMUM
200 - 220 V
180 V
242 V
220 V
198 V
242 V
380 - 415 V
342 V
456 V
2) Only blowers do not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Other parts than the unit
Magnetic switch for
compressor & fan motor 
Operating switch
Protection devices
Electric supply interrupted
Defective power wiring
Cut of power fuse
Too low voltage
Control point is on
condition of "OFF" due to
trouble.
Troubled or defective
contactor
Opened the contact point
with trouble
Measure it with a tester in
case that the same
power source is supplied
to other equipment than
the unit, what and where
trouble can be
discovered by checking
the operation of other
equipment.
Measure it with a tester.
Make short-circuit, then
measure it with a tester. 
Check it with the eyes or
tester.
Check it with the eyes or
tester.
Repair a switch box and
is relative instrument.
Replacement of fuse
Request a power 
supplier to repair.
Check the power source.
Use a thick cable if
necessary.
Replace it if necessary.
Repair or replace it.
Discover the trouble
cause and push the rest
button.
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Air volume change over
switch
Capacitor
Troubled or defective 
contact point
Defected
Check it with the eyes or a
tester
Check it with a tester.
Repair or replace it.
Replace it.
– 66 –
3) Only outdoor fan does not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Motor
Electric Wiring
Over-heated
Layer short
Open wire on operation
Short circuited on 
operation
Check how it is insulated.
Check it with a tester.
Repair or replace it.
Rewiring or repair.
4) Only compressor does not work
WHAT TROUBLED 
COMPLAINTS
HOW TO CHECK
REMEDY
Magnetic switch for
compressor motor
Compressor motor
Compressor
High pressure switch
Electric circuit
Defective contact, 
magnetic coil troubled.
Troubled over-heated 
(layer short)
Troubled or over-heated 
(lock)
Troubled or defective 
contact or operating
Defective connection or
disconnection of the circuit
for compressor.
Check it with the eyes on
with a tester.
Check how it is insulated.
Groaned noise of motor
Check it with a tester.
Check it with a tester.
Repair or replace it.
Replace or repair the
compressor.
Repair or replace it.
Replace it if necessary.
Rewiring or push reset
button.