SERVICE MANUAL
LG
CAUTION
• BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
• ONLY FOR AUTHORIZED SERVICE PERSONNEL.
MODEL: LP-C508T*0
LP-H508T*0
LP-Z508T*0
LP-Z508T*0
10 Floor Standing Type Air Conditioner
Preface
Remote Control
Operation ON/OFF
Operation Mode Selection
• Cooling, Soft Dry, Auto, Fan
Cooling Only Model
• Cooling, Heating, Soft Dry, Fan,
E/heater Heat Pump Model
Fan Speed Selection
Setting the temperature
Timer Control
Airflow Direction Control
• High, Medium, Low
• Up or Down
• Off Timer(1, 2, 3...7 hour)
• Airflow direction Auto-Swing and Manual control
Outdoor Unit
Deice Control
Outdoor Fan Speed Control
Sensing Heat Exchanger Temperature
• De-ice PCB
• One speed
• Heat exchanger temperature sensor (Thermistor)
Service Manual 11
Dimensions
118
37.3
50
80
58.2
959
605.5
440
590
540
540
1513
243
548
899
370
125
210
290
1220
460
460
505
90
130
640
900
900
1) Indoor Unit
2) Outdoor Unit
Air Outlet Vent
Air Inlet Vent
Air Inlet Vent
Window display
Earth Screw
Earth Screw
Air Outlet Vent
Liquid Side SVC Valve
Gas Side SVC Valve
Liquid Side SVC Valve
Gas Side SVC Valve
Control Box
Earth Screw
Earth Screw
Dimensions
12 Floor Standing Type Air Conditioner
Refrigerant cycle diagram
INDOOR UNIT
LIQUID SIDE
CAPILLARY
TUBE
HEAT
EXCHANGER
ACCUMULATOR
MUFFLER
COMPRESSOR
HEAT
EXCHANGER
CAPILLARY
TUBE
HEAT
EXCHANGER
HEAT
EXCHANGER
3-WAY VALVE
GAS SIDE
3-WAY VALVE
LIQUID SIDE
CHECK VALVE
CAPILLARY TUBE
4-WAY VALVE
MUFFLER
COMPRESSOR
COOLING
HEATLNG
DE-ICE
ACCUMULATOR
3-WAY VALVE
GAS SIDE
3-WAY VALVE
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
Refrigerant cycle diagram
Cooling Cycle
Cooling and Heating Cycle