LG LM-1860HL Service Manual ▷ View online

■ 
Cooling Mode with the Sleep Mode
• The setting temperature will be raised by 1°C 30minutes later and by 2°C 1 hour later.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
■ 
Heating Mode with the Sleep Mode.
• The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
- 13 -
Intake Air temp.
COMP. ON
(SET TEMP. +0.5°C)
COMP. OFF
(SET TEMP. -0.5°C)
30 minutes
30 minutes
Delay 3 minutes
More than
3 minutes
1°C
1°C
More than
3 minutes
COMPRESSOR
ON
OFF
ON
OFF
ON
INDOOR FAN
Low
Low
Low
Low
Low
Setting Temp. +3°C
(Compressor OFF)
Setting Temp.
(Compressor ON)
COMPRESSOR
ON
OFF
ON
OFF
ON
OFF
INDOOR FAN
Med.
Med.
Med.
Med.
Med.
Med.
5. Auto Operation
•The operation procedure is as following.
❋ 
If initial mode is decided, that mode is continued without of the room temperature changing.
■ 
Auto Operation for Cooling
- 14 -
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed
are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode
Over
below
21°C
24°C
Soft Dry
below 21°C
Heating
Over 24°C
Cooling
~
Intake-Air temp.
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp. -0.5°C
(Compressor ON)
COMPRESSOR
ON
OFF
ON
OFF
INDOOR FAN
Fuzzy Speed
Intake-air Temperature
Setting Temperature
Over 26°C
25°C
Over 24°C~below 26°C
Intake air -1°C
Over 22°C~below 24°C
Intake air -0.5°C
Over 20°C~below 22°C
Intake air temperature
below 20°C
20°C
Over 20°C~below 30°C
Fuzzy control
below 20°C
20°C
over 30°C
30°C
Operation condition
When Auto Operation
initial start
Controlled by
Fuzzy logic
1/f rhythm
Fan speed
Air DirectionControl
When Switch to
AutoOperation
■ 
Auto Operation for Soft Dry
The Setting temperature will be set to the same that of the current intake-air temperature.
- Compressor ON temperature; Setting temperature +1°C
- Compressor OFF temperature; Setting temperture -0.5°C
■ 
Auto Operation for Heating
- 15 -
Intake Air temp.
Below 20°C
Over 20°C~below 21°C
Setting temp.
20°C
Intake air temperature +0.5°C
21
°
C
Setting temp.
Intake-Air temp.
20.5
°
C
20
°
C
20
°
C
21
°
C
- 16 -
6. Natural Wind by CHAOS logic
There are common rules in the irregular changes amid the breeze of highlands and valleys, the sound of
streams, the songs of birds in the forest and brain waves of relaxation.
Mmm... the breath-taking and touchy feeling of wind from the deep mountains and dark valleys.
Through analysis in its chaos simulator, Goldstar has successfully created such a feeling of freshness and
serenity by analyzing the frequency of natural wind.
Generally natural wind has the following character (frequency-Magnitude), for example dark valley, sea,
mountain wind.
Natural wind function
Frequency(Hz)
Magnitude
So as to make a similar Natural wind function, Indoor fan speed is shifted to high from low or reversely in
according to the CHAOS logic.
Page of 65