JBL SUB 550P (serv.man4) EMC - CB Certificate ▷ View online
Page 8 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) Hazardous live terminals, instructions for wiring
No hazardous live terminal
N/A
c) Instructions for replacing lithium battery
No battery used
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
No battery used
N/A
h) Warning: protective film on CRT face
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Mains plug is provided
P
c) Instructions for permanently connected equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No such device
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
...................................................................:
No such device
N/A
Emission limits under fault conditions ..................... :
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Recognized Component is
provided.
provided.
N/A
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Windings are covered by
lacquer
lacquer
P
Page 9 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No such hygroscopic material
used
used
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
No such construction
P
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Mains transformer T501 and
TR1
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
C03
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Primary wires are double
insulated
insulated
P
Reinforced insulation > 0,4 mm (mm) .................... :
N/A
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
TIW in TR1 and tape in T501
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Page 10 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
TR1: TIW wire
T501: TT093050527D-E
Thin sheet insulation tape with
a thickness of 0.05 mm.
a thickness of 0.05 mm.
And alt.
T501: TD230-0300E+C
Thin sheet insulation tape with
a thickness of 0.08 mm.
a thickness of 0.08 mm.
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Min. 0.4 mm
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Min. 0.4 mm
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
See clause 8.9
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wires detached
N/A
Vibration test carried out ........................................ :
No, no need. See above.
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
Not such apparatus
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Not used
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug is provided
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such devices
N/A
8.19.2
Mains switch ON indication
Power ON, + green LED
N/A
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
C15 (Relay shunt)
P
8.22
Non-separable thin sheet material
No such material
N/A
Page 11 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
253 V/ 60 Hz
U1: 0.280 Vpeak max.
U2: 0.067 Vpeak max.
P
c) Discharge not exceeding 45
µ
C
N/A
d) Energy of discharge not exceeding 350 mJ
< 15 KV
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No ventilation holes on top
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No such part
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
P
If C is not greater than 0,1
µ
F no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
P
b) Test hook of fig. 4 for 10 s (20 N)
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
250 N
P
9.2
No hazard after removing a cover by hand
N/A
10
Insulation requirements
P
10.1
Insulation resistance (M
Ω
) at least 2 M
Ω
min. after
surge test for basic and 4 M
Ω
min. for reinforced
insulation ................................................................. :
N/A
10.2
Humidity treatment 48 h or 120 h .......................... :
48 h and 120 h
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
P
Click on the first or last page to see other SUB 550P (serv.man4) service manuals if exist.