JBL SUB 550P (serv.man4) EMC - CB Certificate ▷ View online

 
Page 28 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
No. 
component 
No. 
fault 
dT (K) / Component 
Other results 
(include description and test duration) 
10 
Capacitor, 
(600pF) in RC 
snubber 
sc 
N/A 
Un = 198 / 253 V 
Resistor, (18
) in RC snubber opened 
Immediately. No hazard. 
11 
D124 
~ to+ 
sc 
N/A 
Un = 198 V, Pn = 35 W 
Nothing happened. Test time: 15 min. 
No hazard. 
12 
C10 
sc 
TR1 winding / 67K 
Un = 253 V, Pn = 5.5 W, In = 0.065 A 
Relay switched OFF. No hazard.  
13 
D2 
N/A 
Un = 253 V, Pn = 0.3 W 
Protection mode immediately.  
No hazard. 
14 
D2 
sc 
N/A 
Un = 253 V, Pn = 45 W 
Normal function. No hazard. 
15 
D6 
N/A 
Un = 253 V, Pn = 47 W 
Normal function. No hazard. 
16 
IC1 
(5-8) 
sc 
N/A 
Un = 253 V, Pn = 0 W 
Mains fuse on standby PCB opened 
immediately; Optocoupler OP1 intact.  
No hazard. 
 
Winding temperature rise measurements 
-- 
 
Ambient temperature t1 (
o
C)  .................................. : 
26
o
C – 28
o
— 
 
Ambient temperature t2 (
o
C)  .................................. : 
27
o
C – 31
o
— 
 
Page 29 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  220-230 V 
Pollution degree .. 2 
Material Group ... :  IIIa 
2 N force on internal parts applied: 
Checked  
30 N force on outside of conductive enclosure applied: 
Checked 
 
Location 
Working Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see mote below. 
Across mains fuse (B) 
230 
325 
2.0 
3.0 
2.3 
3.0 
Across primary directly connected to the 
mains (B) 
230 
325 
2.0 
8.0 
2.3 
8.0 
Hazardous live secondary to Earth (B) 
Optocoupler input to output (R) 
230 
380 
4.0 
7.2 
4.6 
7.2 
Primary to Secondary (R) in transformer 
340 
481 
4.2 
17 
7.2 
17 
Primary to accessible conductive parts (R) 
at mains switch 
285 
403 
4.0 
6.3 
6.0 
6.3 
Primary to Secondary in transf. T501: 
TT093050527D-E (R) 
336 
470 
4.2 
14 
7.0 
14 
Primary to Secondary in transf. T501: 
TD-230-0300E+C (R) 
338 
473 
4.2 
18 
7.0 
18 
Primary to Secondary in transformer TR1 
(R) 
230 
570 
4.5 
> 10 
4.6 
> 10 
Primary to Secondary on Stand-by SMPS 
PCB (R) 
230 
326 
4.0 
6.0 
4.6 
6.2 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 
9 or 10 as required, then the value for clearance is used as the minimum creepage distance. 
"Min" = minimum required. 
"Actual = Actual dimensions measured. 
 
 
 
Page 30 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
14 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model  Value/rating 
Standard 
Approval/ 
reference 
1)
 
Mains 
Transformer 
T501 
Transtec 
Electronic   (Shen 
Zhen) 
Co., Ltd. 
TT0930505
27D-E 
Input rated:  
230 Vac,  
60/50 Hz. 
Output rated 1:  
±
22 Vdc,  
3.9 A. 
Output rated 2:  
±
55 Vdc,  
3.9 A. 
IEC 60065 
applicable part 
Tested in 
appliance 
-Magnet wire 
Jung Shing Wire 
Co., Ltd. 
PEW 
Alt. 
Shen Zhen City 
Chengwei 
Industry Co., Ltd. 
PEW 
Alt. 
Pacific Electric 
Wire & Cable Co., 
Ltd. 
PEWH 
155 
°
C,  
Primary winding 1: 
Ф
 
1.4 mm× 
238 T  
Primary winding 2: 
Ф
 
1.4 mm× 
238 T 
Secondary winding 3-
4: 
Ф
 1.1 mm 
× 95 T  
Secondary winding 4-
5: 
Ф
 1.1 mm 
× 64 T 
Secondary winding 5-
6: 
Ф
 1.1 mm 
× 64 T 
Secondary winding 6-
7: 
Ф
 1.1 mm 
× 95 T 
IEC 60065 
Tested with 
appliance 
-Thermal Cut-
out 
SEKI 
ST-22 
250 Vac, 5 A,  
130 
°
EN 60730-1 
VDE 
-Mylar 
Dupont Teijin 
Films U S L P 
EL 
VTM-2, 105 
°
Applicable parts 
of IEC
 
60065, UL 
94 
UL 
recognized 
-Tube 
Shenzhen 
Gaoertai 
Electronics Co., 
Ltd. 
GET-300 
300 Vac, 105 
°
Applicable parts 
of IEC 60065, 
UL 224 
UL 
recognized 
 
Page 31 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
Component 
Manufacturer/ 
trademark 
Type/model  Value/rating 
Standard 
Approval/ 
reference 
1)
 
Alt. Mains 
Transformer 
T501 
Huizhou GP 
Wiring 
Technology Ltd. 
TD-230-
0300E+C 
Input rated:  
230 Vac,  
60/50 Hz. 
Output rated 1:  
±
22 Vdc,  
3.9 A. 
Output rated 2:  
±
55 Vdc ,  
3.9 A. 
IEC 60065 
applicable part 
Tested in 
appliance 
-Magnet wire 
Tai-I Electric Wire 
& Cable Co., Ltd. 
FTW 
155 
°
C,  
Primary winding 1: 
Ф
 
0.7 mm× 
690 T  
Secondary winding 3-
4: 
Ф
 0.95 mm 
× 96 T  
Secondary winding 4-
5: 
Ф
 0.95 mm 
× 65 T 
Secondary winding 5-
6: 
Ф
 0.95 mm 
× 65 T 
Secondary winding 6-
7: 
Ф
 0.95 mm 
× 96 T 
IEC 60065 
Tested with 
appliance 
-Thermal Cut-
out 
SEKI 
ST-22 
250 Vac, 5 A,  
130 
°
DIN EN 60730-1  VDE 
-Mylar 
Jiangsu Yuxing 
Film Technology 
Co., Ltd. 
6020 
VTM-0, 105 
°
Applicable parts 
of IEC 60065, UL 
94 
UL 
recognized 
-Tube 
ChangYuan 
Electronics 
(Shenzhen) Co., 
Ltd. 
GB-300 
300 Vac, 105 
°
Applicable parts 
of IEC 60065, 
UL 224 
UL 
recognized 
Main Fuse F501  various 
various 
T2.5AL, 250 V  
IEC 60127-3 
VDE 
Mains 
fuseholder 
Littlefuse Inc. 
345121 
10A, 250 V 
EN 60127-1  
VDE 
 
Page of 46
Display

Click on the first or last page to see other SUB 550P (serv.man4) service manuals if exist.