Report No.: TP11100216-ST 
 
TRF No. IEC60065K 
Copy of marking plate 
The artwork below may be only a draft. The use of certification marks on a product must be 
authorized by the respective NCBs that own these marks. 
(Representative) 
 
 
 
 
 
 
 
 
Note:  
-
 
The above markings are the minimum requirements required by the safety standard. For the final 
production, the additional markings which do not give rise to misunderstanding may be added. 
 
 
 
Page 5 of 36 
Report No.: TP11100216-ST 
 
TRF No. IEC60065K 
Test item particulars ..................................................:   
Classification of installation and use ......................:  Class II 
Supply Connection.....................................................:  Mains plug with cord 
.......................................................................................:   
Possible test case verdicts: 
 
- test case does not apply to the test object........... :  N/A (Not Applicable) 
- test object does meet the requirement ................. :  P (Pass) 
- test object does not meet the requirement .......... :  F (Fail) 
Testing: 
 
Date of receipt of test item ........................................ :  Oct. 24, 2011 
Date (s) of performance of tests............................... :  Nov. 9, 2011 ~ Nov. 20, 2011 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and 
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02. 
Throughout this report, a coma is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
When determining the test conclusion, the Measurement Uncertainty of test has been considered. 
This  report  is  for  the  exclusive  use  of  Intertek's  Client  and  is  provided  pursuant  to  the  agreement  between 
Intertek  and  its  Client.  Intertek's  responsibility  and  liability  are  limited  to  the  terms  and  conditions  of  the 
agreement.  Intertek  assumes  no  liability  to  any  party,  other  than  to  the  Client  in  accordance  with  the 
agreement,  for  any  loss,  expense  or  damage  occasioned  by  the  use  of  this  report.  Only  the  Client  is 
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek 
name or one of its marks for the sale or advertisement of the tested material, product or service must first be 
approved in writing by Intertek. The observations and test results in this report are relevant only to the sample 
tested. This report by itself does not imply that the material, product, or service is or has ever been under an 
Intertek certification program. 
The test report only allows to be revised only within the report defined retention period unless standard or 
regulation was withdrawn or invalid. 
 
 
 
 
 
 
Page 6 of 36 
Report No.: TP11100216-ST 
 
TRF No. IEC60065K 
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test 
Certificate includes more than one factory 
location and a declaration from the Manufacturer 
stating that the sample(s) submitted for 
evaluation is (are) representative of the products 
from each factory has been provided.......................:
 Yes 
 Not applicable 
 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies)...........................: Dongguan Meiloon Acoustic Equipment Co., Ltd.                                            
No. 77, Yuanlin Road, Feng Huang Industrial Estate, 
Tangxia, Dongguan, Guangdong Province, 523727, 
China 
General product information: 
The product covered by this Report is a Powered Subwoofer intended for indoor use only. This product is 
provided with Mains plug with cord. 
 
Models SUB550P/230 is identical to Model LS120P/230 except for the enclosure shape. 
 
This test report is based on and entirely replaces Test report with ref. No. 1009955.   
 
 
Page 7 of 36
    
Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
General requirements 
 
Safety class of the apparatus .................................. :  Class II 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test box   The equipment is located at 
the test box and tested. 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit  
 
5.1 
a) Identification, maker  ............................................ : 
 
 
b) Model number or type reference.......................... : 
LS120P/230 and 
SUB550P/230 
 
c) Class II symbol if applicable  ................................ : 
 
 
d) Nature of supply ................................................... : 
a.c. only 
 
e) Rated supply voltage ........................................... : 
220-230 V~ 
 
f) Mains frequency if safety dependant ................... : 
50/60 Hz 
 
g) Rated current or power consumption for apparatus 
supplied by supply apparatus for general use  ........ : 
 
N/A 
 
Measured current or power consumption  ............... : 
 
N/A 
 
Deviation % (max 10%) ........................................... : 
 
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply : 
 
N/A 
 
Measured current or power consumption  ............... : 
1 A 
 
Measured current or power consumption for 
Television set  ........................................................... : 
 
N/A 
 
Deviation % (max 10%) ........................................... : 
 
5.2 
a) Earth terminal  
 
N/A 
 
b) Hazardous live terminals  
No hazardous live terminal 
N/A 
 
c) Markings on supply output terminals 
No such terminals 
N/A 
5.3 
a) Use of triangle with exclamation mark  
 
N/A 
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
  N/A 
5.4 
Instructions for use 
 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
The instruction is provided in 
the user manual 