JBL SDP-40 HD (serv.man2) EMC - CB Certificate ▷ View online

 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
1.2 Product Identification, continued 
 
Cable No. 
Connection Type 
Cable Type Length  Terminator 
92 
Zone 2 Audio Var R 
Audio RCA 1 meter  2 kΩ 
93 
Record Audio Fix L 
Audio RCA 1 meter  2 kΩ 
94 
Record Audio Fix R 
Audio RCA 1 meter  2 kΩ 
95 
Record Audio Var L 
Audio RCA 1 meter  2 kΩ 
96 
Record Audio Var R 
Audio RCA 1 meter  2 kΩ 
97 
Record S/PDIF RCA 
RCA 
1 meter  75 Ω 
98 
Record S/PDIF EIAJ 
optical 
1 meter   
99 
Balanced Audio Out 
Front L 
3 pin XLR  1 meter  2 kΩ 
100 
Balanced Audio Out 
Front R 
3 pin XLR  1 meter  2 kΩ 
101 
Balanced Audio Out 
Center 
3 pin XLR  1 meter  2 kΩ 
102 
Balanced Audio Out LFE 3 pin XLR  1 meter  2 kΩ 
103 
Balanced Audio Out Sub 
3 pin XLR  1 meter  2 kΩ 
104 
Balanced Audio Out Sub 
3 pin XLR  1 meter  2 kΩ 
105 
Balanced Audio Out Side 
3 pin XLR  1 meter  2 kΩ 
106 
Balanced Audio Out Side 
3 pin XLR  1 meter  2 kΩ 
107 
Balanced Audio Out 
Rear L 
3 pin XLR  1 meter  2 kΩ 
108 
Balanced Audio Out 
Rear R 
3 pin XLR  1 meter  2 kΩ 
109 
Balanced Audio Out Aux 
3 pin XLR  1 meter  2 kΩ 
110 
Balanced Audio Out Aux 
3 pin XLR  1 meter  2 kΩ 
111 
Balanced Audio Out 
Zone 2 L 
3 pin XLR  1 meter  2 kΩ 
112 
Balanced Audio Out 
Zone 2 R 
3 pin XLR  1 meter  2 kΩ 
113 
3c16 Power cordset 
 

meters  
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 9 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
1.3   BLOCK DIAGRAM 
 
 
IN
OUT
All 
additional 
cables 
HDMI 
 
 
TV 
 
 
DVD 
 
 
 
 
EUT 
HDMI 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 10 of 29 
 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
2.0  
EN 61000-4-2 ELECTROSTATIC DISCHARGE TEST DESCRIPTION 
 
2.1 TEST SETUP 
 
The EUT setup was placed in the ESD test laboratory in accordance with the IEC 
standard, with the following climatic conditions: 
 
  Temperature: 24.1 
degrees 
 
 
 
 
Relative Humidity:   31 % 
 
The EUT was connected as diagrammed in Section 1.3 of this report.  
 
A horizontal coupling plane (HCP) was placed on a non-conductive table, 0,8 meters 
above the ground plane and connected to the ground plane through two 470-kohm 
resistors. The EUT was placed on the table with an insulating support between the EUT 
and the HCP. The ESD simulator was charged and allowed to discharge through the 
HCP See section 9 for photographs of typical setups. 
 
A vertical coupling plane (VCP) measuring 0,5m by 0,5m was fixed 0,1m from the 
vertical surfaces of the equipment, parallel to them and connected to the ground plane 
through two series 470 kohm resistors.  The ESD simulator was charged and allowed to 
discharge to the VCP.  This test was repeated until all vertical surface areas of the EUT 
were exposed to the VCP. 
 
The ESD events were applied to such points and surfaces of the EUT that are normally 
accessible to the operator for normal operation or maintenance.  Contact discharge is 
the preferred test method.  Air discharges are used where contact discharge cannot be 
applied. 
 
NOTES: 
 
1.  
See Section 2.5, for ESD test locations. 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 11 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
2.2 TEST 
RESULTS 
 
The Lexicon Digital Controller MC-12 with HDMI interfaces meets the requirements set 
forth in EN 61000-4-2.  Detailed test results are found in the following table(s). 
 
2.3   TEST DATA 
 
The test results are based upon 10 discharges at both polarities at each test point 
 
Contact Discharge Data 
PERFORMANCE CATEGORY 
 Level
 
1
 
Level 2
 
Level 3
 
Level
 
4
 
VOLTAGE=>
 
2K
 
V
 
4K V
 
6K V
 
8K
 
V
 
Position Key
 
    +
 
    -
 
    +
 
    -
 
    +
 
    -
 
    +
 
    -
 
1
 
A A A A         
2
 
A A A A         
3
 
A A A A         
4
 
A A A A         
5
 
A A A A         
6
 
A A A A         
7
 
A A A A         
8
 
A A A A         
9
 
A A A A         
10
 
A A A A         
11
 
A A A A         
12
 
A A A A         
13
 
A A A A         
14
 
A A A A         
15
 
A A A A         
16 
A A A A         
17 
A A A A         
18 
A A A A         
19 
A A A A         
 
 
 
 
 
 
 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 12 of 29 