JBL SDP-40 HD (serv.man2) EMC - CB Certificate ▷ View online
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
3.0 EN 61000-4-3 RADIATED RADIO-FREQUENCY TEST DESCRIPTION
3.1 TEST SETUP
The EUT setup was placed in a calibrated uniform field in the ferrite tile chamber. The
field was calibrated using the test methodology in the IEC standard. The following
climatic conditions existed:
Temperature: 23.1
degrees
C
Relative Humidity: 33 %
The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored utilizing the color camera system
contained in the chamber and/or external peripheral equipment located outside of the
chamber. The customer was not present during testing.
3.2 TEST
RESULTS
The Lexicon Digital Controller MC-12 with HDMI interfaces meets the requirements set
forth in EN 61000-4-3.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 17 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
3.3 TEST DATA
Test Results: TEM
4 SIDES 3 AXIS POLARITY
(H / V)
FREQUENCY
(MHz)
VOLTS
PER
METER
1kHz
80% AM
PERFORMANCE
CATEGORY
L V
.15-150
1.8
Yes A
Test Results: Keyed
4 SIDES 3 AXIS POLARITY
(H / V)
FREQUENCY
(MHz)
VOLTS
PER
METER
217 Hz
1/8 duty
PERFORMANCE
CATEGORY
L V
900
3
Yes A
PERFORMANCE CRITERIA EXPLANATION
Category A - Normal Performance within specified limits.
Maintain color bars. No audible 1K tone
Category B - Temporary loss of function that is self-recoverable.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 18 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
3.4 TEST EQUIPMENT
Equipment
Serial #
Last Calibration
Calibration Due
Characterized/Verified Equipment Serial #
C/V Date Due Date
Fluke 6060A Generator
3775031
*
*
IFI LPA-5B Leveling Amplifier
806-1095
*
*
IFI SMX100 Wideband Amplifier 803-1095
*
*
HP 8648C RF Signal Generator 3623A03429
*
*
GTC RF Amplifier 5016A
1170
*
*
Narda E-Field Probe 8760
9022
Verified Verified
Narda E-Field Probe 8760
9025
Verified
N/A
Chase CBL6121A BiConilog
1015
Verified
N/A
EMCO 3143 Log Periodic Ant
9112-1046 Verified
N/A
Calibrated Equipment Serial #
C/V Date Due Date
Boonton 4220A Power Meter 203603AA 08/03/04 08/03/05
IFI EFS-5 E-Field Sensor
807
IFI EFS-5 E-Field Sensor
808
Schaffner EMR-200 Field Probe S-0051
* Signal Generator and Amplifier are characterized with Uniform Field Calibration
Equipment
* Signal Generator and Amplifier are characterized with Uniform Field Calibration
Equipment
Serial #
Characterized Characterization Due
Chamber 3v/m Uniform Field
---
11/04 11/05
Chamber 10v/m Uniform Field
---
11/04 11/05
All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 19 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
3.5 RADIATED RADIO FREQUENCY PHOTOGRAPHS
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 20 of 29
Click on the first or last page to see other SDP-40 HD (serv.man2) service manuals if exist.