JBL SDP-40 HD (serv.man2) EMC - CB Certificate ▷ View online

 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
 
3.0 EN 61000-4-3 RADIATED RADIO-FREQUENCY TEST DESCRIPTION 
 
3.1 TEST SETUP 
 
The EUT setup was placed in a calibrated uniform field in the ferrite tile chamber. The 
field was calibrated using the test methodology in the IEC standard. The following 
climatic conditions existed: 
 
  Temperature: 23.1 
degrees 
 
 
 
 
Relative Humidity:   33 % 
 
The EUT was connected as diagrammed in Section 1.3 of this report.  All testing and 
verification for EUT operation was monitored utilizing the color camera system 
contained in the chamber and/or external peripheral equipment located outside of the 
chamber.  The customer was not present during testing. 
 
 
3.2 TEST 
RESULTS 
 
The Lexicon Digital Controller MC-12 with HDMI interfaces meets the requirements set 
forth in EN 61000-4-3. 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 17 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
3.3 TEST DATA 
 
Test Results: TEM  
 
4 SIDES   3 AXIS   POLARITY 
(H / V) 
FREQUENCY 
(MHz) 
VOLTS 
PER 
METER 
1kHz  
80% AM  
PERFORMANCE 
CATEGORY 
L V 
.15-150 
1.8 
 
Yes A 
 
Test Results: Keyed 
 
4 SIDES   3 AXIS   POLARITY 
(H / V) 
FREQUENCY 
(MHz) 
VOLTS 
PER 
METER 
217 Hz  
1/8 duty  
PERFORMANCE 
CATEGORY 
L V 
900 
 
Yes A 
 
PERFORMANCE CRITERIA EXPLANATION 
 
 
Category A - Normal Performance within specified limits. 
 
 
 
 
Maintain color bars. No audible 1K tone 
 
 
 
 
Category B - Temporary loss of function that is self-recoverable. 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 18 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
3.4 TEST  EQUIPMENT 
 
Equipment    
 
 
Serial # 
Last Calibration 
 Calibration Due 
 
Characterized/Verified Equipment   Serial #  
    C/V Date                    Due Date 
 
Fluke 6060A Generator 
 
3775031 
             *  
                        * 
IFI  LPA-5B Leveling Amplifier 
806-1095 
 
  * 
 
             * 
IFI SMX100 Wideband Amplifier  803-1095 
             * 
 
      
   * 
HP 8648C RF Signal Generator  3623A03429  
  * 
 
 
   * 
GTC RF Amplifier 5016A   
1170   
 
  * 
 
 
   * 
Narda E-Field Probe 8760   
9022   
     Verified                    Verified 
Narda E-Field Probe 8760   
9025     
     Verified   
 
N/A  
Chase CBL6121A BiConilog 
1015   
     Verified   
 
N/A 
EMCO 3143 Log Periodic Ant 
9112-1046       Verified   
 
N/A 
 
               
Calibrated Equipment                      Serial #  
    C/V Date                    Due Date 
 
Boonton 4220A Power Meter          203603AA       08/03/04                      08/03/05  
IFI EFS-5 E-Field Sensor   
  807 
IFI EFS-5 E-Field Sensor   
  808 
Schaffner EMR-200 Field Probe     S-0051  
 
* Signal Generator and Amplifier are characterized with Uniform Field Calibration 
 
 Equipment    
 
 
Serial # 
Characterized      Characterization Due 
 
Chamber 3v/m Uniform Field 
 --- 
               11/04                     11/05 
Chamber 10v/m Uniform Field 
 --- 
               11/04                     11/05 
 
 
 
All equipment used for testing has been calibrated according to the methods and 
procedures defined by the National Institute of Standards and Technology (NIST). 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 19 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
3.5  RADIATED RADIO FREQUENCY PHOTOGRAPHS 
 
 
 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 20 of 29 
Page of 29
Display

Click on the first or last page to see other SDP-40 HD (serv.man2) service manuals if exist.