JBL SDP-40 HD (serv.man2) EMC - CB Certificate ▷ View online

 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
4.0 EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST TEST DESCRIPTION 
 
4.1 TEST SETUP  
 
The EUT setup was placed in the EFT test laboratory in accordance with the IEC 
standard, with the following climatic conditions: 
 
  Temperature: 23.6 
degrees 
 
 
  Relative 
Humidity: 
31 
 
The EUT was connected as diagrammed in Section 1.3 of this report.  All testing and 
verification for EUT operation was monitored utilizing the camera system located in the 
chamber and/or peripheral equipment located outside of the chamber.  The customer 
was not present during testing. 
 
 
The EFT events were applied to such the Mains and to cables at each I/O port of the 
EUT that are normally accessible to the operator for normal operation or maintenance.   
 
NOTES: 
 
1.  
See Section 1.3, for the block diagram of the EUT setup. 
 
 
4.2 TEST 
RESULTS 
 
The Lexicon Digital Controller MC-12 with HDMI interfaces meets the requirements set 
forth in EN 61000-4-4.  Detailed test results are found in the following table(s). 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 21 of 29 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
4.3 TEST  DATA 
       POWER PERFORMANCE CATEGORY 
  
Level 
1
Level 2
Level 3
Level 4
 
 VOLTAGE=>
 
0.5KV
1KV
2KV
4KV
 
Line 
Polarity 
    
N + A 
  
N - A 
  
L + A 
  
L - A 
  
PE +  A 
  
PE -  A 
  
 
 
PERFORMANCE CRITERIA EXPLANATION 
 
 
Category A - Normal Performance within specified limits. 
 
 
 
Maintains color bars. No audible problems. 
 
 
 
 
 
Category B - Temporary loss of function that is self-recoverable. 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 22 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
4.4 TEST  EQUIPMENT 
 
Equipment    
 
 
Serial # 
Last Calibration 
 Calibration Due 
 
Haefely PEFT.1 
 
 
081-944-23       1/21/05        
        1/21/06  
Haefely Coupling Clamp IP4A 
082 148-17        Verified    
           N/A 
 
 
 
 
 
 
 
All equipment used for testing has been calibrated according to the methods and 
procedures defined by the National Institute of Standards and Technology (NIST). 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 23 of 29 
 
 
Test Number - 251-05  
Harman Specialty Group 
Lexicon Digital Controller - MC-12 with HDMI interfaces 
 
 
4.5  ELECTRICAL FAST TRANSIENT/BURST PHOTOGRAPHS 
 
 
 
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 
 
(603) 887 3903 Fax (603) 887 6445 
www.complianceworldwide.com 
Page 24 of 29 