JBL SDP-40 HD (serv.man2) EMC - CB Certificate ▷ View online
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
4.0 EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST TEST DESCRIPTION
4.1 TEST SETUP
The EUT setup was placed in the EFT test laboratory in accordance with the IEC
standard, with the following climatic conditions:
Temperature: 23.6
degrees
C
Relative
Humidity:
31
%
The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored utilizing the camera system located in the
chamber and/or peripheral equipment located outside of the chamber. The customer
was not present during testing.
The EFT events were applied to such the Mains and to cables at each I/O port of the
EUT that are normally accessible to the operator for normal operation or maintenance.
NOTES:
1.
See Section 1.3, for the block diagram of the EUT setup.
4.2 TEST
RESULTS
The Lexicon Digital Controller MC-12 with HDMI interfaces meets the requirements set
forth in EN 61000-4-4. Detailed test results are found in the following table(s).
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 21 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
4.3 TEST DATA
POWER PERFORMANCE CATEGORY
Level
1
Level 2
Level 3
Level 4
VOLTAGE=>
0.5KV
1KV
2KV
4KV
Line
Polarity
N + A
A
N - A
A
L + A
A
L - A
A
PE + A
A
PE - A
A
PERFORMANCE CRITERIA EXPLANATION
Category A - Normal Performance within specified limits.
Maintains color bars. No audible problems.
Category B - Temporary loss of function that is self-recoverable.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 22 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
4.4 TEST EQUIPMENT
Equipment
Serial #
Last Calibration
Calibration Due
Haefely PEFT.1
081-944-23 1/21/05
1/21/06
Haefely Coupling Clamp IP4A
082 148-17 Verified
N/A
All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 23 of 29
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
4.5 ELECTRICAL FAST TRANSIENT/BURST PHOTOGRAPHS
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 24 of 29