JBL SB 100 (serv.man3) EMC - CB Certificate ▷ View online
Page 5 of 68
Report No.: 350-120154AX
TRF No. IEC60065K
Test item particulars .................................................. :
Classification of installation and use ...................... : Table-top or wall-mounting,
Not intend to use for floor standing, Not portable,
Supply Connection .................................................... : Detachable power supply cord
Possible test case verdicts:
- test case does not apply to the test object .......... : N/A (Not Applicable)
- test object does meet the requirement ................. : Pass
- test object does not meet the requirement .......... : Fail
Testing:
Date of receipt of test item........................................ : July 16, 2012
Date (s) of performance of tests .............................. : July 16, 2012 to Aug. 24, 2012
Date (s) of performance of tests .............................. : July 16, 2012 to Aug. 24, 2012
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ......................................................:
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ......................................................:
Yes
Not applicable
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies)…………:
1. TCL TECHNOLY ELECTRONICS (HUIZHOU) CO., LTD
Section 19, Zhongkai High-tech Development Zone,
Huizhou City, Guang Dong Province, China, 516006
Section 19, Zhongkai High-tech Development Zone,
Huizhou City, Guang Dong Province, China, 516006
2. TCL TECHNOLY ELECTRONICS (HUIZHOU) CO., LTD
Section 37, Zhongkai High-tech Development Zone,
Huizhou City, Guang Dong Province, China, 516006
General product information:
-
This subject model is a complete, integrated sound system.
- Mass of equipment: approx. 2.45 kg.
Page 6 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3 General
requirements
-
Safety class of the apparatus .................................. :
Class II.
Pass
4
General test conditions
-
4.1.4
Ventilation instructions require the use of the test
box
box
No.
See remark 1).
See remark 1).
Pass
5
Marking and instructions
-
Comprehensible and easily discernible
Pass
Permanent durability against water and petroleum
spirit
spirit
Pass
5.1 a)
Identification, maker .............................................:
Pass
b) Model number or type reference..........................: CINEMA SB100,
CINEMA STV100
Pass
c) Class II symbol if applicable ................................:
Pass
d)
Nature
of supply....................................................:
Pass
e) Rated supply voltage ...........................................: 100-240V Pass
f) Mains frequency if safety dependant ...................: 50/60Hz Pass
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................:
apparatus supplied by supply apparatus for general
use ............................................................................:
N/A
Measured current or power consumption ...............:
N/A
Deviation
%
(max 10%) ...........................................:
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply.:
us intended for connection to an a.c. mains supply.:
30W Pass
Measured current or power consumption ...............: 5.18W (100V),
4.95W (240V)
Pass
Measured current or power consumption for
Television set ...........................................................:
Television set ...........................................................:
N/A
Deviation
%
(max 10%) ...........................................:
Pass
5.2
a) Earth terminal
Class II apparatus.
N/A
b) Hazardous live terminals
N/A
c) Markings on supply output terminals
N/A
5.3
a) Use of triangle with exclamation mark
Such symbol is indicated on
circuit diagram for specific
components.
circuit diagram for specific
components.
Pass
b) marking on loudspeaker grille, IEC 60417-5036
N/A
Page 7 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.4
Instructions for use
English
(Version in other language will
be provided when submitted
for national approval)
(Version in other language will
be provided when submitted
for national approval)
Pass
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
See remark 1).
Pass
b) Hazardous live terminals, instructions for wiring
No live terminals.
N/A
c) Instructions for replacing lithium battery
No lithium battery.
N/A
d) Class I earth connection warning
N/A
e) Instructions for multimedia system connection
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
N/A
g) Warning: battery exposure to heat
See remark 1).
RTC battery in remote control
unit.
RTC battery in remote control
unit.
Pass
h) Warning: protective film on CRT face
No CRT provided.
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
See remark 1).
Pass
c) Instructions for permanently connected equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6 Hazardous
radiation
-
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
................................................................................... :
N/A
Emission limits under fault conditions ..................... :
N/A
7
Heating under normal operating conditions
-
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
See appended table CL. 7.1.
Pass
7.1.1
Temperature rise of accessible parts
See appended table CL. 7.1.
Pass
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table CL. 7.1.
Pass
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table CL. 7.1.
Pass
7.1.4
Temperature rise of windings
See appended table CL. 7.1.
Pass
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table CL. 7.1.
Pass
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
<0.2A. N/A
Page 8 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
shock
-
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Not done without a tool.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
Pass
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
See CL. 8.6.
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
See appended table CL. 13.
Pass
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Switching Transformer
T5311 comply with CL. 14.3.
T5311 comply with CL. 14.3.
Pass
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
See appended table CL. 14.
CY501, CY502, CY506 and
CY507: Y1
CY501, CY502, CY506 and
CY507: Y1
Pass
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) ....................: See appended table CL. 8.8 &
8.9.
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A