Page 13 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 N/A 
 
14 Components 
14.1 Resistors 
 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors. 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
No such resistors. 
N/A 
 Resistors 
separately approved ...............................: 
 
N/A 
14.2 
Capacitors and RC units  
See appended table CL. 14. 
Pass 
 
Capacitors separately approved  : 
 
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14:2005 .............:
CY501, CY502, CY506, 
CY507: Y1 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 .......................:
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better ..................:
 N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ........................................................................: 
 N/A 
14.3 
Inductors and windings  
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
See CL. 20.1.4. 
Pass 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
T5311:  
Type: BCK-BH140 
Mfg. Trademark: 
 
 
-Alt. use- 
Type: BCK-03EF25 
Mfg. Trademark: 
 
 
-Alt. use- 
Type: BCK-EE25-S-5632 
Mfg. Trademark: 
 
Pass 
 
Transformers and inductors separately approved .: 
No. 
N/A 
Page 14 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.3.2 
General  
T5311: Isolating transformer. 
Pass 
 
Insulation material complies with clause 20.1.4  
See appended table CL. 14. 
Pass 
14.3.3 
Constructional requirements  
See appended table CL. 14. 
Pass 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
See appended table CL. 13. 
Pass 
14.3.3.2 
Transformers meet the constructional requirements  See appended table CL. 13. 
Pass 
14.3.4 
Separation between windings 
 
Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)..............................: 
See appended table CL. 13. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
See appended table CL. 8.8 & 
8.9. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 N/A 
14.3.4.3 
Separating transformers with at least basic insulation  
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 Pass 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
See appended table CL.13. 
T5311. 
Pass 
 
Coil formers and partition walls > 0,4 mm  
See appended table CL. 8.8 & 
8.9. 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 N/A 
14.4 
High voltage components  
 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
 
Pass 
 
Protective devices used within their ratings  
Primary fuse: F501 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table CL.13. 
Pass 
Page 15 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.5.1.1 
a) Thermal cut-outs separately approved  
No thermal cut-outs provided.
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
See appended table CL.14. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...: 
F501: T3.15AL 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ................: 
 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
Not replaced without a tool. 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
No PTC-S. 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
 N/A 
14.6 Switches 
 
 
Pass 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Certified power switch 
provided, complies with the 
requirements and 
characteristics. 
(See appended table 14) 
Pass 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
No Safety interlocks provided.
N/A 
Page 16 of 68 
Report No.: 350-120154AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
Not provide. 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 N/A 
14.10 Batteries 
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
See appended table CL.14. 
Pass 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
Pass 
 
b) Comply with IEC 60747-5-5: 2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8  
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
14.12 
Surge suppression varistors  
VR501 
Pass 
 
Comply with IEC 61051-2  
See appended table CL.14. 
Across the line, protected by 
fuse-link, F501. 
Pass 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 N/A 
 
Page of 77