DOWNLOAD JBL S-820 Service Manual ↓ Size: 3.03 MB | Pages: 63 in PDF or view online for FREE

Model
S-820
Pages
63
Size
3.03 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
s-820.pdf
Date

JBL S-820 EMC - CB Certificate ▷ View online

 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
8 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
4   T E S T  E N V I R O N M E N T  
4.1 
Address of the test laboratory 
 
  
mikes-testingpartners gmbh 
  
  Ohmstrasse 
2-4 
  
  94342 
Strasskirchen 
  
  Germany 
 
 
 
 
4.2 Environmental 
conditions 
 
During the measurement the environmental conditions were within the listed ranges: 
 
 
Temperature: 
15-35 ° C 
 
 
 
 
Humidity: 30-60 
 
 
 
 
Atmospheric pressure: 
86-106 kPa 
 
 
 
 
4.3 
Statement of the measurement uncertainty 
 
The data and results referenced in this document are true and accurate. The reader is cautioned that there may 
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated 
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit 
modelling – Uncertainty in EMC measurements“ and is documented in the quality system acc. to DIN EN ISO/IEC 
17025. Furthermore, component and process variability of devices similar to that tested may result in additional 
deviation. The manufacturer has the sole responsibility of continued compliance of the device. 
 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
9 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
5   T E S T   C O N D I T I O N S   A N D   R E S U L T S  
5.1 Conducted 
disturbance 
For test instruments and accessories used see section 6 Part A 4
5.1.1  Description of the test location 
 
Test location: 
Shielded Room S2 
 
5.1.2  Photo documentation of the test set-up 
 
 
 
5.1.3 Test 
result 
 
Frequency range: 
0.15 MHz - 30 MHz 
 
Min. limit margin by 
3.8 dB at 0.16 MHz 
 
The requirements are 
FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s).  
 
 
 
 
 
 
 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
10 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
5.1.4 Test 
protocol 
 
Test point: 
L1 
Operation mode: 
1 kHz 1/8 rated output power 
Remarks: Ground 
connection 
Date: 
15. October 2007 
Tested by: 
Michael Hackl 
Result: passed 
 
Peak Measurement
See Table for QP and AV  v alues
L1 OM1
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
A
m
p
lit
ude
 dB
V
)
File Number: 
Standard: 
Equipment - 
Serial No. - 
Op Mode 1 - 
Operator - 
LmtAVVoltage
LmtQPVoltage
Peak_11
AVG_11
QP_11
AV_11
 
 
Frequency 
QP Level 
QP Margin 
QP Limit 
AV Level 
AV Margin 
AV Limit 
MHz dB(µV) dB  dB dB(µV) dB  dB 
0.000 
22.2 
22.2 22  22.2 22.2 22 
0.16 61.7 
-3.8  65.5 29.8  -25.7  55.5 
0.22 52.6 
-10.2 62.8 21.3  -31.6  52.8 
0.315 38.4 -21.5  59.8 9.6 
-40.3  49.8 
0.55 31.9 
-24.1 56.0 5.3 
-40.7  46.0 
0.575 
50 
-6.0 
56.0 
   
 
0.635 45.4 -10.6  56.0 11.9  -34.1  46.0 
0.77 15.2 
-40.8 56.0 2.0 
-44.0  46.0 
0.82 12.4 
-43.6 56.0 1.8 
-44.2  46.0 
1.295 44.2 -11.8  56.0 11.4  -34.6  46.0 
1.730 47.8 -8.2  56.0 14.4  -31.6  46.0 
2.48 34.3 
-21.7 56.0 6.4 
-39.6  46.0 
3.1 29.4 
-26.6 
56.0 5.4 
-40.6  46.0 
 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
11 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
Test point: 
Operation mode: 
1 kHz 1/8 rated output power 
Remarks: Ground 
connection 
Date: 15. 
October 
Tested by: 
Michael Hackl 
Result: passed 
 
Peak Measurement
See Table for QP and AV  v alues
N OM1
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
A
m
p
lit
ude
 dB
V
)
File Number: 
Standard: 
Equipment - 
Serial No. - 
Op Mode 1 - 
Operator - 
LmtAVVoltage
LmtQPVoltage
Peak_21
AVG_21
QP_21
AV_21
 
 
Frequency 
QP Level 
QP Margin 
QP Limit 
AV Level 
AV Margin 
AV Limit 
MHz dB(µV) dB  dB dB(µV) dB  dB 
0.000 
22.2 
22.2 22  22.2 22.2 22 
0.155 58.9 -6.9  65.7 27.1  -28.6  55.7 
0.22 48.0 
-14.8 62.8 17.0  -35.8  52.8 
0.5 35.4 
-20.6 
56.0 6.2 
-39.8  46.0 
0.6 51.7 
-4.3 56.0 17.0  -29.0  46.0 
0.615 51.5 -4.5  56.0 17.1  -28.9  46.0 
0.72 32.7 
-23.3 56.0 3.3 
-42.7  46.0 
0.975 35.1 -20.9  56.0 4.1 
-41.9  46.0 
1.16 52 -4.0  56.0 
18.0 -28.0 46.0 
 
1.44 36.9 
-19.1 56.0 4.8 
-41.2  46.0 
1.715 50.7 -5.3  56.0  
2.455 42.7 -13.3  56.0 11.4  -34.6  46.0 
3.07 36.8 
-19.2 56.0 9.0 
-37.0  46.0 
 
 
 
Page of 63
Display