DOWNLOAD JBL S-820 Service Manual ↓ Size: 3.03 MB | Pages: 63 in PDF or view online for FREE

Model
S-820
Pages
63
Size
3.03 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
s-820.pdf
Date

JBL S-820 EMC - CB Certificate ▷ View online

 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
28 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : Ch.1 Output 
Mode of EUT : Ch.1 Input UNBALANCED 
Criterion : Sound 
Ref.-S/N :  88 dB 
Monitoring : Speaker 
Output : 52 mW/4 Ohm 
Channel : Ch.1 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : Ch.2 Input BALANCED 
Mode of EUT : Ch.2 Input BALANCED 
Criterion : Sound 
Ref.-S/N :  61 dB 
Monitoring : Speaker 
Output : 51 mW/4 Ohm 
Channel : Ch.2 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
Frequency Level 
Limit  Margin Frequency Level 
Limit  Margin 
[MHz] [dB(µV)] 
[dB(µV)]  [dB] 
[MHz] [dB(µV)] 
[dB(µV)]  [dB] 
70 125 
120 5  71 125 
120 5 
72 124 
120 4  73 124 
120 4 
74 123 
120 3  75 122 
120 2 
76 122 
120 2  77 122 
120 2 
78 122 
120 2  79 122 
120 2 
80 122 
120 2  81 123 
120 3 
82 123 
120 3  83 124 
120 4 
84 124 
120 4  85 125 
120 5 
86 125 
120 5  87 125 
120 5 
87 125 
120 5  88 125 
120 5 
89 
125 
120 
5      
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
29 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : Ch.2 Input UNBALANCED 
Mode of EUT : Ch.2 Input UNBALANCED 
Criterion : Sound 
Ref.-S/N :  37 dB 
Monitoring : Speaker 
Output : 51 mW/4 Ohm 
Channel : Ch.2 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : Ch.2 Output 
Mode of EUT : Ch.2 Input BALANCED 
Criterion : Sound 
Ref.-S/N :  85 dB 
Monitoring : Speaker 
Output : 51 mW/4 Ohm 
Channel : Ch.2 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
30 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : MAINS 
Mode of EUT : Ch.1 Input BALANCED 
Criterion : Sound 
Ref.-S/N :  88 dB 
Monitoring : Speaker 
Output : 51 mW/4 Ohm 
Channel : Ch.1 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
 
 
 
 
Multifunction mode : Amplifier / Test point (injection into) : MAINS 
Mode of EUT : Ch.2 Input UNBALANCED 
Criterion : Sound 
Ref.-S/N :  54 dB 
Monitoring : Speaker 
Output : 53 mW/4 Ohm 
Channel : Ch.2 Output 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
31 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
7.2 
Immunity requirements - S3 Test protocol(s) 
 
 
 
 
Multifunction mode : Amplifier 
Mode of EUT : Ch.1 Input BALANCED 
Criterion : Sound 
Ref.-S/N :  85 dB 
Monitoring : Speaker 
Output : 53 mW/4 Ohm 
Channel : Ch.1 Output 
Start Margin : 6 dB over limit 
K2 Factor : 0,5 dB 
 
 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
Frequency Level 
Limit  Margin Frequency Level 
Limit  Margin 
[MHz] [dB(µV/m)] 
[dB(µV/m)]  [dB] 
[MHz] [dB(µV/m)] [dB(µV/m)]  [dB] 
82 130 
125 5  83 129 
125 4 
84 
130 
125 
5      
 
 
 
 
 
Multifunction mode : Amplifier 
Mode of EUT : Ch.2 Input UNBALANCED 
Criterion : Sound 
Ref.-S/N :  87 dB 
Monitoring : Speaker 
Output : 51 mW/4 Ohm 
Channel : Ch.2 Output 
Start Margin : 6 dB over limit 
K2 Factor : 0,5 dB 
 
 
Test Engineer : Rüdiger Gramsch 
Date : 16.10.2007 
Place :  Immunity Site 1 
 
 
Page of 63
Display