DOWNLOAD JBL S-820 Service Manual ↓ Size: 3.03 MB | Pages: 63 in PDF or view online for FREE

Model
S-820
Pages
63
Size
3.03 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
s-820.pdf
Date

JBL S-820 EMC - CB Certificate ▷ View online

 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
4 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
2   S U M M A R Y  
 
2.1 General 
remarks 
 
None 
 
2.2 
Summary for all EMC tests 
 
Type of test
 
Test result 
EMC emission: 
A4 
Conducted emissions (AC mains power / DC power) 
Fulfilled 
A5 
Radiated emissions from ancillary equipment 
Not Applicable 
A6 
Conducted emissions (Antenna port) 
Not Applicable 
A7 Disturbance 
power 
Fulfilled 
A9 
Radiated disturbance (ERP) 
Not Applicable 
FL&H 
Harmonic current emissions 
Fulfilled 
FL&H 
Voltage fluctuations and flicker 
Fulfilled 
 
Test result 
Performance 
criteria 
Immunity: 
I2 
Electrostatic discharge (ESD) 
Fulfilled 
I3 
Radio frequency electromagnetic field 
Fulfilled 
I4 
Fast transients, common mode (BURST) 
Fulfilled 
S1 
Immunity requirements 
Not Applicable 
 
S2 Immunity 
requirements 
Fulfilled 
S2c 
Immunity requirements 
Not Applicable 
 
S3 Immunity 
requirements 
Fulfilled 
S4 
Immunity requirements 
Not Applicable 
 
 
 
2.3 Final 
assessment 
 
The equipment under test 
fulfills the EMC requirements cited in clause 1 test standards. 
 
 
Date of receipt of test sample 
acc. to storage records 
 
 
 
Testing commenced on 
15. October 2007 
 
 
 
Testing concluded on 
16. October 2007 
 
 
Checked by: 
Tested by: 
 
 
 
Eduard Stangl 
Dipl. Ing.(FH) 
Technical Director 
 Michael 
Hackl 
EMC Senior Expert 
Michael Hackl 
Ich bin der Verfasser 
dieses Dokuments 
2007.10.25 13:47:28 
+02'00'
Eduard Stangl 
Ich bestätige die Richtigkeit 
und Integrität dieses 
Dokuments 
2007.10.25 13:51:32 +02'00'
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
5 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
3   E Q U I P M E N T  U N D E R  T E S T  
3.1 
Photo documentation of the EuT 
 
 
 
 
 
 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
6 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
3.2 
Power supply system utilised 
 
Power supply voltage 
:  230 V / 50 Hz / 1
φ 
 
3.3 
Short description of the Equipment under Test (EuT) 
HIFI-Stereo integrated amplifier used for reproduction of audio information’s. 
 
Number of tested samples: 
Serial number: 
 
Feature list: 
 
 - Single scart 
 - Headphone socket 
 - Audio input 
 - Double scart 
 - Front/side A/V input 
 - Audio output 
 - Triple scart 
 - Speaker output 
 - PiP module 
 - Teletext 
 - 50 Hz 
 - 100 Hz 
 - Double tuner 
 - PC in/out 
 - Mono 
 - Stereo 
 -                
 
 
 
EuT operation mode: 
 
 
The equipment under test was operated during the measurement under the following conditions: 
 
- 1 kHz 1/8 rated output power 
- 1 kHz audio signal 
- pink noise 1/8 rated output power 
 
 
EuT configuration: 
(The CDF filled by the applicant can be viewed at the test laboratory.) 
 
The following peripheral devices and interface cables were connected during the measurements: 
 
-  
Model 
:  
 
-   
Model :  
 
-   
Model :  
 
Modifications during the EMC test:   
 
None 
 
- unscreened power cables 
 
- customer specific cables 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F32090-00-00HM
, page 
7 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
3.4 Performance 
level 
 
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment 
under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed 
between the manufacturer and the purchaser of the product. 
 
Definition related to the performance level: 
 
 
 
based on the used product standard 
 
 
based on the declaration of the manufacturer, requestor or purchaser 
 
Criterion A:  
Definition: normal performance within limits specified by the manufacturer, requestor or purchaser: 
 
The equipment shall continue to operate as intended during the test. No change of actual operating state (for 
example change of channel) is allowed as a result of the application of the test. The criterion of compliance with 
the requirement is a wanted to unwanted audio signal ratio of 
≥ 40 dB at a wanted audio signal level of 50 mW, 
or at another audio signal level specified by the manufacturer. No degradation of test picture is allowed. 
 
Criterion B:  
Definition: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment 
under test recovers its normal performance, without operator intervention: 
 
After the test, the equipment shall continue to operate as intended without operator intervention. No loss of  
function is allowed after the test when the apparatus is used as intended, but failures which are recovered  
automatically but which cause temporary delay in processing, are permissible. No change of actual operating state
is allowed as a result of the application of the test. During the test, degradation of performance is allowed. 
 
Criterion C:  
Definition: temporary loss of function or degradation of performance, the correction of which requires operator intervention: 
 
 
 
 
 
Criterion D:  
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to hardware or software, or loss of data: 
 
 
 
 
 
Page of 63
Display