JBL S-5160 EMC - CB Certificate ▷ View online

 
 
page 9 of 49 
Ref.No.:416321  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 N 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 N 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 N 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 P 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 Bump 
test 
 
12.1.2 
Vibration test 
No connection or part which 
might impair safety can 
become loose. 
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ..................... :
Prim-sec: 6mm (on control 
board, prim wind-C7) 
Prim-earthed accessible parts: 
3mm (on control board) 
13.1.1 
Reduction applied if the 3 conditions are met  ....... :  
 
Reduction applied for Grade 2 winding wire  ......... :  
13.1.2 
Use of cemented joints .......................................... :  
 
Tests to confirm cemented joints 
 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ....................................... :
 
3.4mm (on control board) 
 
 
page 10 of 49 
Ref.No.:416321  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
 
14 COMPONENTS 
 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N 
 
a) Resistors separately approved ......................... :  
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved ......................... :  
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
 
14.2.1 
Y capacitors tested to IEC 60384-14, 2:nd Edition :  
14.2.2 
X capacitors tested to IEC 60384-14, 2:nd Edition :  
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ..................... :
 N 
14.2.5 
Capacitors with volume exceeding 1750 mm
3
 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ..................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm
3
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60384-1, 
4.38 category B or better ....................................... :
 N 
 
Shielded by a barrier to FV 0 or metal  .................. :  
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type  ............................. :
Amplifier Technologies inc.  
56-0052 &  56-0048 (main) 
MCI  4-05-4016CE (standby) 
 
Transformers and inductors separately approved  :  
14.3.2 
Isolating transformer complies with 14.3.3, 
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3, 14.3.4.1, 14.3.5.1 
 
 
page 11 of 49 
Ref.No.:416321  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
Separating transformer complies with 14.3.3, 
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
 N 
 
Flammability test of insulating material acc. to 
20.1.4 (except in thin sheet form) 
Standby transformer bobbin 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
Prim-sec (main): 3layers tape, 
creepage dist/clearance: 
56-0048=9mm, 56-0052>10mm
  
Prim-sec (standby): 
3mm+2layers tape 
 
Coil formers and partition walls 
≥ 0.4 mm 
 1.5mm (standby) 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Standby transformer: 
Prim-sec (via iron core): 
4.5mm+2layers tape 
(Iron core of standby transformer is not 
connected to accessible parts)
 
 
Coil formers and partition walls 
≥ 0.4 mm 
1.24mm (standby) 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
 
 
page 12 of 49 
Ref.No.:416321  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
 
b) Thermal cut-outs tested as part of the 
submission 
Located in main transformers. 
Located on amplifier PCB  
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices resettable by soldering 
 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
 P 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : T4AL 250V 
(panel mount  mains 
fuses) 
T160mAL  250V 
(internal mains 
fuse) 
T8L  250V
 (internal sec fuse)
 
14.5.2.3 
Not possible to connect fuses in parallel ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
 P 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
 
PTC-S devices (15 W) category FV 1 or better 
 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
Sec F1/F2 (UL-fuse) 
 
14.6 
Switches 
     (See appended table) 
14.6.1 Permanently 
connected 
equipment 
provided 
with 
an all-pole mains switch unless 5.4.2 is met 
 N 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................... :
No N 
 
Switch readily accessible and not in mains cord 
 
 
Exception for automatic switching 
Can be controlled by data link 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
(Blue LEDs on front) 
 
Indication by marking meets Cl. 5 
 
 Indication 
of 
the 
OFF 
position 
 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................ :
 N 
 
Stand-by mode clearly discernible  ........................ : (Red LED near switch on front) 
 
Exception for low Stand-by current < 0.7 mA (peak) 
 N 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 N 
Page of 56