JBL S-5160 EMC - CB Certificate ▷ View online
page 25 of 49
Ref.No.:416321
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
9
Q17 b-e
(Channel 2)
sc
254.4
5min
-
-
Normal conditions. Nothing
happens.
OK
10
Q15 c-b
(Channel 1)
sc 254.4 2h
20min
Sec F1/F2
6.3/0 I
in
=4.4A P
in
=870W
Ch.1 in protection mode
U
U
out channel1
= 50.6V dc
Tries to switch on in a cycle.(I
F1sec
=
9.5A, I
F2sec
= 8A)
Right transf. prim wind dT=92K
Sec wind dT=85K
Left transf. prim wind dT=41K
Enclosure, middle part top above
heat sink ch.1 dT= 19K
Front dT= 21K
No high temps.
Sec wind dT=85K
Left transf. prim wind dT=41K
Enclosure, middle part top above
heat sink ch.1 dT= 19K
Front dT= 21K
No high temps.
OK
11
Q15 b-e
(Channel 2)
sc
254.4
5min
-
-
Normal conditions. Nothing
happens.
OK
12a
Q13 c-b
(Channel 1)
sc 254.4 5min
Sec F1/F2
0/6.4 I
in
=6.8A P
in
=1400W
F
1
opened immediately: I
in
=4.5A
P
in
=870W
U
out channel1
= 50.9V dc
No high temps.
OK
12b
Q13 c-b
(Channel 1)
sc 198 2h
Sec F1/F2
5.5/7.5 I
in
=6.7A P
in
=1200W U
out
=30.4V
F
2
opened after 55s (something
broke): I
in
=4A P
in
=620W
U
out channel1
= 40V dc
Enclosure, middle part top above
heat sink ch.1 dT= 15K
Front dT= 16K
No high temps.
heat sink ch.1 dT= 15K
Front dT= 16K
No high temps.
OK
13
Q10 e
(Channel 1)
d 198 5min
Sec F1/F2
>20/>20
F1 and F2 opened immediately.
OK
14a
C26
(Channel 1)
sc 198 5min
F1 (prim,
rear panel
mount)
11A
F1 (prim) opened after 1s. OK
14b
C26
(Channel 3)
sc 198 5min
F2 (prim,
rear panel
mount)
11.5A F2 (prim) opened after 1s. OK
15
C22
(Channel 1)
sc 198 5min
F1 (prim,
rear panel
mount)
11A
F1 (prim) opened after 1s. OK
16
Q1 pin 7
(Channel 1)
d 254.4
30min
Sec F1/F2
0/1.7 I
in
=3A P
in
=500W
U
out channel1
= 0V
I
F1 sec
= 0, I
F2 sec
= 1.7A
Enclosure, middle part top above
heat sink ch.1 dT= 21K
Front dT=18K OK
heat sink ch.1 dT= 21K
Front dT=18K OK
page 26 of 49
Ref.No.:416321
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
17
C1
(control PCB)
sc 198 5min
Prim fuse
F2 on
control PCB
454mA Prim fuse F2 (on control board)
opened within 3s.
454mA > 2.1x T160mA (=336mA)
454mA > 2.1x T160mA (=336mA)
OK
18
D1
(control PCB)
sc 198 5min
Prim fuse
F2 on
control PCB
540mA Prim fuse F2 (on control board)
opened within 2s.
540mA > 2.1x T160mA (=336mA)
540mA > 2.1x T160mA (=336mA)
OK
page 27 of 49
Ref.No.:416321
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Main
Transformer (L)
Transformer (L)
Amplifier
Technologies
Technologies
56-0052
-
IEC 60065
Tested in the
appliance
Main
Transformer (R)
Transformer (R)
Amplifier
Technologies
Technologies
56-0048
-
IEC 60065
Tested in the
appliance
Thermal cut-out
(in main transf.)
(in main transf.)
Thermtrol 7AM030A5
115°C
IEC
60065
sub.cl. 14.5.1.1b)
Tested in the
appliance
Plastic part
inside main
transformers
inside main
transformers
MDE Nylon
N6050L,
N6050HSL
94V-2 Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Standby
Transformer T2
Transformer T2
MCI Transformer
Corp.
Corp.
4-05-4016CE
-
IEC 60065
Tested in the
appliance
Bobbin Standby
Transformer T2
Transformer T2
EI Dupont
70G33L
3mm/94HB
Complies with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
AC Line Inductor Elytone
YT-15629 ELY
-
IEC 60065
Tested in the
appliance
Inductor bobbin EI Dupont De
Nemours
70G33L 3mm/94HB
Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Alt. AC Line
Inductor (toroidal)
Inductor (toroidal)
Powertronix
AA-040059-CH
-
IEC 60065
Tested in the
appliance
Inductor board
PCB
PCB
Jiangsu Suang
Electronic
Electronic
various V-0
(E154554)
Complies with
FV-1
(IEC 60707:81)
Accepted in the
appliance
Prim Terminal
block
block
Weco 426
380V
2.5mm
2
94V-2
Complies with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Thermal cut-out,
on amplifier board
on amplifier board
(SELCO)
Uchiya
Uchiya
UP72 75°C
IEC
60065
sub.cl. 14.5.1.1b)
Tested in the
appliance
Panel mount
Prim Fuse F1/F2
(upper/lower)
Prim Fuse F1/F2
(upper/lower)
Wickman
-
T4AL 250V
IEC 60127
Prim Fuse F2 (on
control board)
control board)
Littel Fuse
-
T160mAL 250V
IEC 60127
Sec Fuse F1/F2 Wickman
-
T8L 250V
IEC 60065
Tested in the
appliance
(UL-rec)
Appliance inlet
Qualtec
Electronics
Electronics
701W
10A 250V
IEC 60320
Cordset:
Ching Cheng
IEC 60227
page 28 of 49
Ref.No.:416321
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Plug
Cord
Connector
Wire Material
EL-211
H05VV-F
EL-701
16A 250V
3x1.0mm
2
10A 250V
Cordset for UK:
Plug
Cord
Connector
Tumbler
EL 210
H05VV-F
EL 701
13A 250V
3x1.0mm
2
10A 250V
BS1363-A
IEC 60227
BS4491
BSI
Fan
Mechatronics
F1238S12B
DC12V 0.18A
IEC 60065
Tested in the
appliance
Mains relay
K1/K2
K1/K2
Song Shuan
852-W-1A-C1
5/80A
IEC 60065
sub.cl. 14.6.6b
Tested by
SEMKO
Mains thermistor
(inrush current
limiter)
(inrush current
limiter)
Ametherm SL32
10015
10 ohm,
steady state current
max 15A,
energy rating max
150J
(calculated=137J)
IEC 60065
Tested in the
appliance
PCB,
FR-4 spacings
FR-4 spacings
Circuit MFG
1
94V-0
Complies with
FH3-40mm/min
(IEC 60707:81)
-
Panel mounted
Prim Fuse
holder
(upper/lower)
Prim Fuse
holder
(upper/lower)
Bussmann HTB-44M 94V-0
6.3A/250V
IEC60127 VDE
Alt. Panel
mounted Prim
Fuse holder
(upper/lower)
mounted Prim
Fuse holder
(upper/lower)
Schurter FEU0031.1706
10A/250V
IEC
60127
Prim Fuse
holder on
Control Board
holder on
Control Board
Keystone
Electronics
Electronics
4527 94V-0
Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Plastic
connectors on
sec wires from
main transf.
connectors on
sec wires from
main transf.
Molex Mini-Fit
JR
p/n: 9-01-2040,
39-01-3043
94V-2 Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Plastic tubings
on wires
on wires
Alpha FIT-221V
VW-1
Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Plastic sheet
behind standby
PCB
behind standby
PCB
Formex Formex-20BK
0.5mm/94V-0
Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Plastic sheet
inside main
transformers
inside main
transformers
Formex Formex-20BK
0.5mm/94V-0
Complies
with
FH3-40mm/min
(IEC 60707:81)
Accepted in the
appliance
Click on the first or last page to see other S-5160 service manuals if exist.